TL;DR

This paper presents a lightweight, rigid, and hermetically sealed mechanical and cooling system for the Large Size Telescope (LST) camera in the Cherenkov Telescope Array (CTA). The design uses an aluminum tubular and load-bearing structure with integrated water or air cooling to maintain electronics temperature stability, ensuring <1 mm pixel displacement and supporting a 2000 kg total camera mass limit for optimal telescope performance.

ABSTRACT

Mechanics of the camera for the large size telescopes of CTA must protect and provide a stable environment for its instrumentation. This is achieved by a stiff support structure enclosed in an air and water tight volume. The structure is specially devised to facilitate extracting the power dissipated by the focal plane electronics while keeping its weight small enough to guarantee an optimum load on the telescope structure. A heat extraction system is designed to keep the electronics temperature within its optimal operation range, stable in time and homogeneous along the camera volume, whereas it is decoupled from the temperature in the telescope environment. In this contribution, we present the details of this system as well as its verification based in finite element analysis computations and tested prototypes. Finally, issues related to the integration of the camera mechanics and electronics will be dealt with.

Motivation & Objective

  • Design a robust mechanical structure to protect the LST camera's sensitive electronics and photodetectors from harsh environmental conditions at the CTA site.
  • Ensure precise pixel positioning with <1 mm displacement under thermal and mechanical stress to maintain high physics performance.
  • Develop an efficient cooling system (water or air) to regulate electronic temperature and extend component lifespan.
  • Maintain total camera mass below 2000 kg to prevent structural stress on the telescope.
  • Enable easy maintenance through modular design, accessible components, and a motorized blind system for daylight operation.

Proposed method

  • Employ a hollow aluminum tubular structure to minimize weight while achieving sufficient stiffness (max 2.5 mm axial deformation under 2500 kg load).
  • Use a sandwich-like load-bearing structure with two aluminum plates joined by columns to support clusters and ensure thermal and mechanical stability.
  • Integrate water or air cooling via heat pipes, aluminum heat spreaders, and thermal interface materials (silicon grease) to transfer heat from electronics to the load-bearing plates.
  • Implement a dual-motor, 3-stage blind system made of aluminum and Plexiglas to protect photomultipliers during daylight and maintain functionality at any telescope orientation.
  • Design modular clusters with front-side insertion and rear-side backplane connectivity using slits and alignment pins for precise positioning.
  • Use a rail-and-carriage system for camera-frame fixation allowing up to 40 cm displacement to compensate for focal length misalignments during installation and maintenance.

Experimental results

Research questions

  • RQ1How can the mechanical design of the LST camera ensure pixel stability within 1 mm under thermal and mechanical loads?
  • RQ2What cooling strategy (water vs. air) best maintains electronic temperature stability while minimizing weight and complexity?
  • RQ3How can the camera be protected from environmental extremes (temperature shocks, humidity, solar load) while remaining lightweight and maintainable?
  • RQ4What mechanical solution enables reliable operation of the camera blind system in any telescope orientation?
  • RQ5How can the total camera mass be kept under 2000 kg while integrating cooling, shielding, and electronics?

Key findings

  • The tubular structure exhibits a maximum axial deformation of 2.5 mm under a 2500 kg load, meeting stiffness requirements for pixel stability.
  • The water-cooled cluster design weighs 663 kg, while the air-cooled version is 504 kg, both within the 2000 kg total camera mass limit.
  • The load-bearing structure with heat pipes and thermal interface materials effectively transfers heat from electronics to the outer plates.
  • The motorized blind system, weighing 60 kg and measuring 3×3 m², operates reliably in all orientations and protects photomultipliers during daylight.
  • The modular cluster design allows front-side insertion and rear-side backplane connection via slits, ensuring precise alignment and easy maintenance.
  • The total estimated camera mass is 1243 kg for water cooling and 1109 kg for air cooling, leaving sufficient margin (<750 kg) for remaining components to stay under the 2000 kg limit.