[Paper Review] Memory-efficient Learning for High-Dimensional MRI Reconstruction
This paper proposes memory-efficient learning (MEL) to enable training of deep learning-based unrolled MRI reconstructions on high-dimensional data (3D and 2D+time) using only a single 12GB GPU. By recomputing intermediate activations during backpropagation instead of storing them, MEL reduces GPU memory use by a factor of N (number of unrolls) with only a marginal increase in computation, enabling superior image quality with sharper edges and improved metrics on in-vivo 3D and cardiac cine MRI datasets.
Deep learning (DL) based unrolled reconstructions have shown state-of-the-art performance for under-sampled magnetic resonance imaging (MRI). Similar to compressed sensing, DL can leverage high-dimensional data (e.g. 3D, 2D+time, 3D+time) to further improve performance. However, network size and depth are currently limited by the GPU memory required for backpropagation. Here we use a memory-efficient learning (MEL) framework which favorably trades off storage with a manageable increase in computation during training. Using MEL with multi-dimensional data, we demonstrate improved image reconstruction performance for in-vivo 3D MRI and 2D+time cardiac cine MRI. MEL uses far less GPU memory while marginally increasing the training time, which enables new applications of DL to high-dimensional MRI.
Motivation & Objective
- To overcome GPU memory limitations that restrict training of deep learning-based unrolled MRI reconstructions on high-dimensional data such as 3D and 2D+time MRI.
- To enable the use of a larger number of unrolls in unrolled reconstruction networks, which improves image quality by capturing finer spatial and temporal textures.
- To demonstrate that memory-efficient learning (MEL) allows training of complex, high-dimensional MRI reconstruction models on standard hardware (single 12GB GPU) without sacrificing performance.
- To validate that leveraging high-dimensional redundancy through MEL leads to improved quantitative metrics and clinically relevant image quality improvements.
Proposed method
- MEL reduces memory usage by storing only one layer’s activation at a time during backpropagation, instead of all N unrolls, by recomputing intermediate features in reverse order.
- The method relies on the invertibility of each layer in the unrolled network, allowing gradients to be computed by re-evaluating each layer’s forward pass from the output backward.
- The unrolled reconstruction is formulated using the MoDL framework, where each unroll alternates between a CNN-based regularization layer and a data consistency (DC) layer solved via conjugate gradient.
- The DC layer is implemented using a closed-form solution involving the adjoint of the encoding operator and a Tikhonov regularization term.
- The residual CNN denoiser used in the regularization layer is invertible, which is essential for MEL’s re-computation strategy.
- Training is performed on a single 12GB GPU, with MEL enabling models that would otherwise exceed memory limits.
Experimental results
Research questions
- RQ1Can memory-efficient learning (MEL) enable training of deep learning-based unrolled MRI reconstruction models on high-dimensional data such as 3D and 2D+time MRI?
- RQ2Does using a larger number of unrolls in unrolled reconstruction, made possible by MEL, lead to improved image quality and quantitative metrics in high-dimensional MRI?
- RQ3Can MEL-trained models generalize to prospectively undersampled data without fully-sampled ground truth, indicating clinical robustness?
- RQ4How does MEL compare to standard backpropagation in terms of memory usage and training time for high-dimensional MRI reconstruction?
Key findings
- 3D MoDL with MEL achieved a pSNR of 32.11 ± 2.05 dB on in-vivo 3D knee MRI, outperforming 2D MoDL and PICS.
- 2D+time MoDL with MEL and 10 unrolls achieved a pSNR of 27.42 ± 3.21 dB on cardiac cine MRI, a 0.6 dB improvement over 4-unroll baseline.
- The 2D+time MoDL with MEL and 10 unrolls produced more natural motion profiles and better-resolved papillary muscles compared to 4-unroll version.
- 3D MoDL with MEL showed superior SSIM (0.830 ± 0.038) and FID (41.48) compared to PICS and 2D MoDL on 3D MRI.
- On prospectively undersampled 3D FSE knee scans, 3D MoDL with MEL preserved sharper edges and finer textures despite mismatched scanning parameters.
- Visual and quantitative results confirmed that MEL enables high-dimensional reconstructions with improved image quality, including better contrast, texture continuity, and motion fidelity.