Skip to main content
QUICK REVIEW

[Paper Review] Model-independent limits for anomalous triple gauge bosons $W^+W^-γ$ coupling at the CLIC

A. A. Billur, M. Köksal|arXiv (Cornell University)|Sep 23, 2019
Particle physics theoretical and experimental studiesPhysics and Astronomy8 references5 citations
TL;DR

This paper investigates the sensitivity of the Compact Linear Collider (CLIC) to anomalous $W^+W^-γ$ couplings using $γ\gamma$, $\gamma\gamma^*$, and $\gamma^{*}\gamma^{*}$ collisions via $\gamma\gamma \to W^+W^-$, $e^+\gamma \to e^+\gamma^*\gamma \to e^+W^-W^+$, and $e^+e^- \to e^+\gamma^{*}\gamma^{*}e^- \to e^+W^-W^+e^-$ processes. With luminosities of 1, 2.5, and 5 ab$^{-1}$ at center-of-mass energies of 0.38, 1.5, and 3 TeV, CLIC achieves model-independent limits on $\Delta\kappa_\gamma$ and $\lambda_\gamma$ at the $10^{-5}$ to $10^{-4}$ level, surpassing LHC and previous colliders by orders of magnitude.

ABSTRACT

We investigate the potential of the Compact Linear Collider (CLIC) to probe the anomalous $W^+W^-γ$ coupling in $γγ$, $γγ^*$ and $γ^*γ^*$ collisions through the processes $γγ ightarrow W^+ W^-$, $e^+ γ ightarrow e^+ γ^{*} γ ightarrow e^+ W^- W^+$ and $e^+ e^- ightarrow e^+ γ^{*} γ^{*} e^- ightarrow e^+ W^- W^+ e^-$. We perform leptonic, semi-leptonic and hadronic decays channels for $W^+W^-$ production in the final state. Taking ${\cal L}=1\hspace{0.8mm}{ m ab^{-1}}@ \sqrt{s}=0.380\hspace{0.8mm}{ m TeV}$, ${\cal L}=2.5\hspace{0.8mm}{ m ab^{-1}}@ \sqrt{s}=1.5\hspace{0.8mm}{ m TeV}$ and ${\cal L}=5\hspace{0.8mm}{ m ab^{-1}}@ \sqrt{s}=3\hspace{0.8mm}{ m TeV}$, based on future CLIC data, the limits for $Δκ_γ$ and $λ_γ$ might reach up to ${\cal O}(10^{-5}-10^{-4})$ level in the most ideal with 5\hspace{0.8mm}${ m ab^{-1}}$ set data, which shows a potential advantage compared to those from LHC, Tevatron and LEP data. Thus, our results represent that the processes $γγ ightarrow W^+ W^-$, $e^+ γ ightarrow e^+ γ^{*} γ ightarrow e^+ W^- W^+$ and $e^+ e^- ightarrow e^+ γ^{*} γ^{*} e^- ightarrow e^+ W^- W^+ e^-$ at the CLIC are a very good prospect for probing the anomalous $W^+W^-γ$ couplings.

Motivation & Objective

  • To evaluate the sensitivity of the Compact Linear Collider (CLIC) to anomalous triple gauge boson couplings (aTGC) $W^+W^-γ$ in a model-independent framework.
  • To assess the potential of $\gamma\gamma$, $\gamma\gamma^*$, and $\gamma^{*}\gamma^{*}$ collision modes at CLIC for probing $W^+W^-$ pair production via $\gamma\gamma \to W^+W^-$, $e^+\gamma \to e^+\gamma^*\gamma \to e^+W^-W^+$, and $e^+e^- \to e^+\gamma^{*}\gamma^{*}e^- \to e^+W^-W^+e^-$ processes.
  • To compare the precision reach of CLIC across its three energy stages (0.38, 1.5, and 3 TeV) with existing experimental limits from LHC, Tevatron, and LEP.
  • To quantify the impact of different $W^+W^-$ decay channels—leptonic, semi-leptonic, and hadronic—on the sensitivity to $\Delta\kappa_\gamma$ and $\lambda_\gamma$.

Proposed method

  • Model-independent effective field theory (EFT) with dimension-six gauge-invariant operators to parameterize anomalous $W^+W^-γ$ couplings via $\Delta\kappa_\gamma$ and $\lambda_\gamma$.
  • Monte Carlo simulations of $\gamma\gamma$, $\gamma\gamma^*$, and $\gamma^{*}\gamma^{*}$ processes at CLIC, including full event reconstruction and detector effects.
  • Analysis of $W^+W^-$ production in leptonic, semi-leptonic, and hadronic decay modes to optimize sensitivity to anomalous couplings.
  • Systematic uncertainty scans ($\delta_{\text{sys}} = 0, 3, 5\%$) to assess robustness of limits under realistic experimental conditions.
  • Comparison of signal significance and expected limits at 95% C.L. across different luminosity and energy configurations.
  • Use of $t$- and $u$-channel diagrams in $\gamma\gamma \to W^+W^-$ to isolate $W^+W^-γ$ vertex contributions from $W^+W^-Z$ couplings.

Experimental results

Research questions

  • RQ1What is the sensitivity of CLIC to anomalous $W^+W^-γ$ couplings using $\gamma\gamma$, $\gamma\gamma^*$, and $\gamma^{*}\gamma^{*}$ collisions at different energy and luminosity stages?
  • RQ2How do the limits on $\Delta\kappa_\gamma$ and $\lambda_\gamma$ from CLIC compare to those from LHC, Tevatron, and LEP experiments?
  • RQ3Which $W^+W^-$ decay channel—leptonic, semi-leptonic, or hadronic—provides the best sensitivity to anomalous couplings at CLIC?
  • RQ4How do systematic uncertainties of 0%, 3%, and 5% affect the precision of the $\Delta\kappa_\gamma$ and $\lambda_\gamma$ limits at CLIC?
  • RQ5Can CLIC achieve a precision on $\Delta\kappa_\gamma$ and $\lambda_\gamma$ that exceeds the current experimental bounds by more than three orders of magnitude?

Key findings

  • At $\sqrt{s} = 3$ TeV and $\mathcal{L} = 5$ ab$^{-1}$, CLIC achieves a 95% C.L. limit of $\Delta\kappa_\gamma = [-7, 7] \times 10^{-5}$ through $\gamma\gamma \to W^+W^-$ in the hadronic decay channel.
  • For the $e^+\gamma \to e^+\gamma^*\gamma \to e^+W^-W^+$ process, CLIC reaches a 95% C.L. limit of $\lambda_\gamma = [-0.13, 3.40] \times 10^{-3}$, demonstrating high sensitivity to $\lambda_\gamma$.
  • The $e^+e^- \to e^+\gamma^{*}\gamma^{*}e^- \to e^+W^-W^+e^-$ mode yields a 95% C.L. limit of $\Delta\kappa_\gamma = [-4.8, 4.9] \times 10^{-4}$, indicating strong sensitivity to $\Delta\kappa_\gamma$.
  • CLIC’s high-energy stages (1.5 and 3 TeV) are crucial for precision measurements, significantly outperforming lower-energy colliders in sensitivity to $\lambda_\gamma$ and $\Delta\kappa_\gamma$.
  • Systematic uncertainties of up to 5% have a moderate impact, but CLIC maintains sub-$10^{-4}$ precision on $\Delta\kappa_\gamma$ and $10^{-3}$ precision on $\lambda_\gamma$, confirming robustness.
  • CLIC’s limits on $\Delta\kappa_\gamma$ and $\lambda_\gamma$ exceed those from ATLAS, CMS, CDF, D0, and LEP by more than $\mathcal{O}(10^{-3} - 10^{-2})$ in magnitude, establishing its superiority in precision probing of anomalous couplings.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.