[Paper Review] Model validation and tolerancing of scalar vortex masks in the High Contrast Imaging Testbed (HCIT) facility
The paper evaluates scalar vortex masks for high-contrast imaging, quantifies how mask defects and model mismatches affect EFC performance, and validates lab results against simulations to support future HWO designs.
The Habitable Worlds Observatory (HWO) mission will require coronagraphs capable of suppressing starlight at the $\sim 10^{-10}$ contrast level to directly image exo-Earths. High contrast achromatic coronagraphic masks are the missing critical component to achieving this. Vortex coronagraphs, particularly scalar vortex designs with an achromatic focal plane mask, offer key advantages. While all vortex coronagraph varieties provide high throughput, a small inner working angle, and rejection of low-order aberrations, the scalar approach enables dual-polarization observation in a single optical path. This simplifies instrument design and increases transmission by maintaining light from the planet in two orthogonal polarization states. In this work we test scalar vortex masks and investigate their contrast limitations. We perform phase metrology to assess the mask defects and manufacturing deviations and use it to refine the coronagraphic model used for electric field conjugation (EFC) algorithms and end-to-end simulations. We also measure the impact of model-mismatch with EFC by varying model parameters including clocking angle, and central wavelength in laboratory demonstrations. Finally, we validate our scalar vortex models against experimental results from the High Contrast Imaging Testbed (HCIT) facility at JPL by finding good agreement between lab and simulated performance. This ultimately helps to benchmark simulated contrast predictions for future scalar vortex coronagraph designs for HWO.
Motivation & Objective
- Assess how scalar vortex mask defects and fabrication deviations impact starlight suppression in broadband operation.
- Quantify sensitivity of EFC performance to model mismatches such as clocking angle, central wavelength, and alignment.
- Refine optical models and validate them against HCIT laboratory results to support future mission design.
- Explore mitigation strategies for central defects and evaluate model-free approaches for diagnosing performance limits.
Proposed method
- Perform phase metrology on a combined sawtooth and central Roddier dimple scalar vortex mask prototype.
- Develop and refine a vortex mask model by fitting to digital holographic microscope phase measurements.
- Use EFC in laboratory testbeds to study performance under controlled model mismatches (clocking, wavelength) in narrowband and broadband regimes.
- Investigate central defects via simulations including opaque central spots and misalignment effects.
- Compare experimental broadband performance on IACT with predictions from refined simulations (Falco) to validate the model.

Experimental results
Research questions
- RQ1How do central defects and fabrication deviations in scalar vortex masks affect broadband contrast?
- RQ2How sensitive is model-based electric field conjugation (EFC) to clocking angle and central wavelength mismatches for scalar vortex masks?
- RQ3Can model-free approaches (e.g., iEFC) diagnose or mitigate mask/model mismatches and Lyot stop alignment issues?
- RQ4How well do refined simulations predict lab performance across a range of wavelengths for scalar vortex coronagraphs?
Key findings
- Central defects in the mask dramatically degrade broadband contrast; however, an opaque central spot can mitigate this only if it remains smaller than roughly 20 microns in diameter and is precisely aligned.
- Clocking mismatches in broadband EFC show a clear optimum near a clocking angle of about 27°, with performance degrading for other model angles.
- Wavelength offsets (central design wavelength) degrade performance less severely; offsets of ±20 nm still yield contrasts below 1.5×10^-7, indicating EFC robustness to small λ0 errors.
- Model-free iEFC can remove leakage streaks caused by mask/model mismatches and revealed Lyot stop misalignment as the actual cause of poor performance, guiding calibration improvements.
- Experimentally measured broadband contrast on IACT agrees closely with refined optical model predictions (Falco), validating the modeling framework for future scalar vortex designs.

Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.