[Paper Review] Multi-Modal Interaction Control of Ultrasound Scanning Robots with Safe Human Guidance and Contact Recovery

Xiangjie Yan, Yongpeng Jiang|arXiv (Cornell University)|Feb 11, 2023
Soft Robotics and ApplicationsEngineering3 citations
TL;DR

This paper proposes a multi-modal interaction control scheme for ultrasound scanning robots that seamlessly integrates scanning, contact recovery, and human-guided modes into a unified control input using adaptive weighting factors. The system ensures safety and stability during transitions, enabling real-time doctor intervention while maintaining high-quality, stable imaging even under patient motion or manual guidance.

ABSTRACT

Ultrasound scanning robots enable the automatic imaging of a patient's internal organs by maintaining close contact between the ultrasound probe and the patient's body during a scanning procedure. Comprehensive, high-quality ultrasound scans are essential for providing the patient with an accurate diagnosis and effective treatment plan. An ultrasound scanning robot usually works in a doctor-robot co-existing environment, hence both efficiency and safety during the collaboration should be considered. In this paper, we propose a novel multi-modal control scheme for ultrasound scanning robots, in which three interaction modes are integrated into a single control input. Specifically, the scanning mode drives the robot to track a time-varying trajectory on the patient's body under the desired impedance model; the recovery mode allows the robot to actively recontact the body whenever physical contact between the ultrasound probe and the patient's body is lost; the human-guided mode renders the robot passive such that the doctor can safely intervene to manually reposition the probe. The integration of multiple modes allows the doctor to intervene safely at any time during the task and also maximizes the robot's autonomous scanning ability. The performance of the robot is validated on a collaborative scanning task of a carotid artery examination.

Motivation & Objective

  • Address the need for safe, collaborative ultrasound scanning robots that can operate autonomously while allowing real-time doctor intervention.
  • Overcome limitations in existing robots that lack safe human-robot interaction during scanning tasks.
  • Integrate multiple control modes—scanning, recovery, and human-guided—into a single, unified control framework.
  • Ensure system stability and safety during mode transitions, even under disturbances like patient movement or manual guidance.
  • Enable high-quality, continuous ultrasound imaging by maintaining optimal contact force and trajectory tracking.

Proposed method

  • Propose a unified control input that combines three modes—scanning, recovery, and human-guided—using adaptive weighting factors (ap, af, ah) to govern mode transitions.
  • Implement a desired impedance model for scanning mode, regulating contact force and trajectory tracking via a dynamic stiffness matrix.
  • Use force and position error feedback to trigger the recovery mode when contact is lost, with a dynamic stiffness adjustment to re-establish contact.
  • Activate the human-guided mode when contact is lost beyond recovery capability or when the doctor manually intervenes, making the robot fully passive.
  • Embed mode transitions within the control law using continuous switching functions based on contact force (E fz), tracking error (‖x̃‖), and intervention signals.
  • Theoretical stability is ensured via passivity-based analysis, even during dynamic mode changes, preserving safety in all operational states.

Experimental results

Research questions

  • RQ1How can a single control framework effectively integrate multiple interaction modes—scanning, recovery, and human-guided—while ensuring safety and stability?
  • RQ2What control mechanisms enable seamless, automatic transitions between modes in response to patient motion or doctor intervention?
  • RQ3How can contact force be regulated to ensure patient safety while maintaining high-quality ultrasound imaging during autonomous scanning?
  • RQ4To what extent can the robot maintain stable contact and trajectory tracking under disturbances such as patient movement or manual guidance?
  • RQ5Can the proposed control scheme preserve system passivity and stability during mode transitions, even in complex clinical scenarios?

Key findings

  • The robot successfully maintained stable contact with the patient at an optimal force of approximately 10 N, with contact force variation kept below 0.3 N, ensuring patient safety and comfort.
  • Tracking error remained small (‖x̃‖ ≤ 0.04 m) throughout the scanning task, indicating high-precision trajectory following under dynamic conditions.
  • High-quality ultrasound images with clear vascular wall edges were consistently acquired during scanning mode, even when the patient moved or turned their head.
  • The system automatically transitioned between modes—scanning, recovery, and human-guided—without instability or abrupt changes, as confirmed by continuous mode activation signals (ap, af, ah).
  • During manual interventions (e.g., gel application or probe repositioning), the robot entered a passive human-guided mode within seconds, with stiffness dropping to zero, ensuring safe responsiveness.
  • The control scheme demonstrated robustness in handling disturbances such as patient head movements (e.g., at 68 s) and intentional probe displacement (e.g., at 35–45 s), with rapid recovery and minimal image degradation.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.