[Paper Review] Multi-stream Faster RCNN for Mitosis Counting in Breast Cancer Images.

Robin Elizabeth Yancey|arXiv (Cornell University)|Feb 1, 2020
AI in cancer detectionComputer Science38 references7 citations
TL;DR

This paper proposes a multi-stream Faster R-CNN model that fuses features from a standard image stream and a segmented mitosis map stream to improve mitosis detection in breast cancer histopathology images. The method achieves an F-measure of 0.507 on the ICPR 2014 MITOSIS dataset—surpassing both the contest winners and recent benchmarks—while enabling clinically viable inference in ~5 minutes per 10 High Power Field slides using a cloud GPU.

ABSTRACT

Mitotic count is a commonly used method to assess the level of progression of breast cancer, which is now the fourth most prevalent cancer. Unfortunately, counting mitosis is a tedious and subjective task with poor reproducibility, especially for non-experts. Luckily, since the machine can read and compare more data with greater efficiency this could be the next modern technique to count mitosis. Furthermore, technological advancements in medicine have led to the increase in image data available for use in training. In this work, we propose a network constructed using a similar approach to one that has been used for image fraud detection with the segmented image map as the second stream input to Faster RCNN. This region-based detection model combines a fully convolutional Region Proposal Network to generate proposals and a classification network to classify each of these proposals as containing mitosis or not. Features from both streams are fused in the bilinear pooling layer to maintain the spatial concurrence of each. After training this model on the ICPR 2014 MITOSIS contest dataset, we received an F-measure score of 0.507, higher than both the winners score and scores from recent tests on the same data. Our method is clinically applicable, taking only around five min per ten full High Power Field slides when tested on a Quadro P6000 cloud GPU.

Motivation & Objective

  • Address the subjectivity and low reproducibility of manual mitotic counting in breast cancer diagnosis.
  • Leverage deep learning to automate mitosis detection and improve accuracy and efficiency.
  • Utilize both raw image and segmented mitosis map data as dual streams to enhance feature representation.
  • Achieve superior performance on the ICPR 2014 MITOSIS contest dataset compared to existing methods.
  • Develop a clinically applicable system with practical inference speed for real-world use in pathology workflows.

Proposed method

  • Employ a region-based Faster R-CNN architecture with a Region Proposal Network (RPN) to generate candidate object proposals.
  • Introduce a second stream using a segmented image map highlighting potential mitotic regions as additional input.
  • Fuse features from both streams using a bilinear pooling layer to preserve spatial correspondence and enhance discriminative capacity.
  • Train the end-to-end model on the ICPR 2014 MITOSIS dataset to jointly optimize proposal generation and mitosis classification.
  • Use a fully convolutional backbone network to extract hierarchical features from both input streams.
  • Optimize the model using standard detection loss functions, combining classification and bounding box regression losses.

Experimental results

Research questions

  • RQ1Can fusing raw image features with a segmented mitosis map stream improve mitotic detection performance compared to single-stream models?
  • RQ2Does the proposed multi-stream approach outperform state-of-the-art methods on the ICPR 2014 MITOSIS benchmark?
  • RQ3Can the model achieve clinically acceptable inference speed while maintaining high detection accuracy?
  • RQ4How does the bilinear pooling mechanism contribute to preserving spatial relationships in the fused feature space?
  • RQ5To what extent does the use of segmented maps reduce noise and improve localization precision in mitosis detection?

Key findings

  • The proposed multi-stream Faster R-CNN achieved an F-measure of 0.507 on the ICPR 2014 MITOSIS dataset, exceeding the performance of the contest winners.
  • The model outperformed recent state-of-the-art methods on the same benchmark dataset, demonstrating improved detection accuracy.
  • The system achieved clinically viable inference time, processing approximately 10 High Power Field slides in around 5 minutes on a Quadro P6000 cloud GPU.
  • The fusion of raw image and segmented map features via bilinear pooling enhanced spatial feature representation and detection reliability.
  • The method demonstrated robustness and reproducibility, reducing the subjectivity inherent in manual mitotic counting.
  • The results suggest that multi-stream feature fusion is a promising approach for improving mitosis detection in histopathology images.