Skip to main content
QUICK REVIEW

[Paper Review] Muon (g-2) Technical Design Report

J. Grange, V. Guarino|arXiv (Cornell University)|Jan 27, 2015
Particle physics theoretical and experimental studiesPhysics and Astronomy131 citations
TL;DR

The Muon (g-2) Technical Design Report details the design and technical foundation for a precision measurement of the muon anomalous magnetic moment at Fermilab, using a refurbished storage ring from Brookhaven National Laboratory. The experiment aims to measure the muon g-2 four times more precisely than the E821 experiment, testing whether the observed discrepancy with the Standard Model prediction signals new physics beyond the Standard Model.

ABSTRACT

The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.

Motivation & Objective

  • To measure the muon anomalous magnetic moment with a fourfold improvement in precision over the E821 experiment at Brookhaven National Laboratory.
  • To determine whether the observed 3σ discrepancy between the E821 measurement and the Standard Model prediction is due to new physics beyond the Standard Model.
  • To validate and implement a technically advanced experimental setup using a relocated and upgraded storage ring at Fermilab.
  • To reduce systematic uncertainties in the measurement through improved detector systems, beam control, and data acquisition.
  • To support the DOE CD-2/3 approval process by providing a comprehensive technical and scientific basis for the experiment.

Proposed method

  • Utilization of the existing muon storage ring from the E821 experiment at Brookhaven National Laboratory, relocated and upgraded for operation at Fermilab.
  • Implementation of a high-intensity, polarized muon beam injected into a precision magnetic field with a uniformity of better than 1 part in 10^6.
  • Employment of a ring-shaped detector system with scintillating fiber trackers, electromagnetic calorimeters, and Cherenkov detectors to measure muon decay positrons with high resolution.
  • Application of advanced beam diagnostics and feedback systems to stabilize the muon beam and minimize systematic errors from beam motion and magnetic field inhomogeneities.
  • Use of a segmented, high-precision magnetic field mapping system to calibrate the uniformity of the magnetic field with sub-ppm accuracy.
  • Implementation of a full data acquisition and trigger system designed to record decay positron time-of-flight and position with nanosecond and millimeter resolution, respectively.

Experimental results

Research questions

  • RQ1Is the observed 3σ discrepancy in the muon anomalous magnetic moment between the E821 measurement and the Standard Model prediction statistically significant or due to systematic error?
  • RQ2Can the new experiment reduce experimental uncertainty by a factor of four to definitively resolve the discrepancy?
  • RQ3What are the dominant systematic uncertainties in the measurement, and how can they be minimized through detector and beamline design?
  • RQ4To what extent can the theoretical hadronic contributions to the muon g-2 be improved to reduce the uncertainty in the Standard Model prediction?
  • RQ5Can the relocated and upgraded storage ring at Fermilab achieve the required magnetic field uniformity and beam stability for the precision measurement?

Key findings

  • The experiment is designed to achieve a relative precision of 0.14 ppm on the muon anomalous magnetic moment, representing a fourfold improvement over the E821 experiment.
  • The magnetic field uniformity in the storage region is targeted at better than 1 part in 10^6, critical for minimizing systematic errors.
  • The detector system is designed to measure positron time-of-flight with a resolution of 150 ps and position with 1 mm resolution, enabling precise reconstruction of muon decay vertices.
  • The beamline and vacuum system are engineered to maintain a muon beam with a momentum spread of less than 0.1% and a transverse emittance below 100 μm-rad.
  • The full technical design includes comprehensive beam diagnostics, feedback systems, and field mapping to control systematic uncertainties below the 0.2 ppm threshold.
  • The report serves as the official technical foundation for the E989 experiment, approved for DOE CD-2/3 and enabling the transition to construction and operation at Fermilab.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.