[Paper Review] MyWear: A Smart Wear for Continuous Body Vital Monitoring and Emergency Alert
MyWear proposes a smart wearable garment that continuously monitors vital signs—heart rate, stress, muscle activity, and fall events—using embedded sensors and a deep neural network (DNN) for real-time anomaly detection. The system achieves 96.9% average accuracy and 97.3% precision in classifying abnormal heartbeats and 98.2% accuracy in detecting myocardial infarction, with emergency alerts sent to medical personnel in critical situations.
Smart healthcare which is built as healthcare Cyber-Physical System (H-CPS) from Internet-of-Medical-Things (IoMT) is becoming more important than before. Medical devices and their connectivity through Internet with alongwith the electronics health record (EHR) and AI analytics making H-CPS possible. IoMT-end devices like wearables and implantables are key for H-CPS based smart healthcare. Smart garment is a specific wearable which can be used for smart healthcare. There are various smart garments that help users to monitor their body vitals in real-time. Many commercially available garments collect the vital data and transmit it to the mobile application for visualization. However, these don't perform real-time analysis for the user to comprehend their health conditions. Also, such garments are not included with an alert system to alert users and contacts in case of emergency. In MyWear, we propose a wearable body vital monitoring garment that captures physiological data and automatically analyses such heart rate, stress level, muscle activity to detect abnormalities. A copy of the physiological data is transmitted to the cloud for detecting any abnormalities in heart beats and predict any potential heart failure in future. We also propose a deep neural network (DNN) model that automatically classifies abnormal heart beat and potential heart failure. For immediate assistance in such a situation, we propose an alert system that sends an alert message to nearby medical officials. The proposed MyWear has an average accuracy of 96.9% and precision of 97.3% for detection of the abnormalities.
Motivation & Objective
- To develop a continuous, real-time body vital monitoring system using smart wearable garments for improved personal health management.
- To address the lack of real-time health analysis and emergency alert mechanisms in existing commercial wearables.
- To integrate deep learning for automated detection of cardiac abnormalities and fall events to enhance patient safety.
- To enable remote monitoring and early prediction of heart failure through cloud-based EHR integration and AI analytics.
- To improve rehabilitation outcomes for athletes and patients through real-time muscle activity and movement tracking.
Proposed method
- Embeds multi-sensor arrays (ECG, EMG, accelerometer) into a textile-based garment for continuous physiological data acquisition.
- Employs a deep neural network (DNN) model trained on ECG and EMG data to classify abnormal heartbeats and predict potential heart failure.
- Uses time-domain and Poincaré plot-based HRV metrics (e.g., RMSSD, SDNN, pNNxx) for stress and cardiac health assessment.
- Applies a fall detection algorithm that triggers alerts when resultant acceleration drops below 1g and rapidly increases above +1g.
- Transmits raw and processed physiological data to the cloud for long-term EHR storage and post-processing analysis.
- Integrates a mobile application for real-time visualization of ECG, heart rate, body temperature, HRV score, and muscle activity mapping.
Experimental results
Research questions
- RQ1How can a smart wearable garment enable continuous, real-time monitoring of multiple physiological parameters including heart rate, stress, muscle activity, and fall events?
- RQ2What deep learning architecture can accurately classify abnormal heartbeats and predict myocardial infarction from ECG and EMG signals in wearable settings?
- RQ3How effective is the proposed system in detecting falls with high sensitivity and specificity compared to existing methods?
- RQ4Can real-time anomaly detection in physiological data improve early intervention and emergency response in healthcare?
- RQ5What is the performance of the DNN model in classifying cardiac abnormalities compared to state-of-the-art approaches?
Key findings
- The DNN model achieved 96.9% average accuracy and 97.3% precision in classifying abnormal heartbeats, outperforming existing models such as DCST+ABC-SVM (96.1%) and H-Box (95%).
- The system demonstrated 98.2% accuracy in detecting myocardial infarction, surpassing prior methods like Acharya et al. (93.5%) and Kojuri et al. (95.6%).
- Fall detection achieved 98.5% accuracy, 98% sensitivity, and 99.5% specificity, exceeding Mezghani et al. (98% accuracy) and Hemalatha et al. (92% accuracy).
- The confusion matrix confirmed high model reliability, with minimal false positives and negatives in heartbeat classification.
- The Poincaré plot analysis revealed significant HRV variability (e.g., RMSSD = 71.87 ms, SDNN = 66.51 ms), indicating effective stress and cardiac function monitoring.
- The mobile application successfully visualized real-time ECG, heart rate, body temperature, and muscle activity on a human map, enabling user and clinician awareness.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.