Skip to main content
QUICK REVIEW

[Paper Review] New HST spectra indicate the QSO PG1718+4807 will not give the primordial deuterium abundance

David Kirkman, David Tytler|ArXiv.org|Mar 20, 2001
Scientific Research and DiscoveriesPhysics and Astronomy7 references10 citations
TL;DR

New Hubble Space Telescope STIS spectra of QSO PG1718+4807 reveal that the previously suspected deuterium absorption on the blue side of the Lyα line is unlikely to be deuterium. With 98% confidence, the data rule out deuterium due to inconsistent velocity width and redshift, concluding that this system cannot yield the primordial deuterium abundance due to complex, multi-component absorption structure.

ABSTRACT

The z ~ 0.701 absorption system towards the QSO PG1718+4807 is the only example of a QSO absorption system which might have a deuterium/hydrogen ratio approximately ten times the value found towards other QSOs. We have obtained new STIS spectra from the Hubble Space Telescope of the Lyman alpha and Lyman limit regions of the system. These spectra give the redshift and velocity dispersion of the neutral hydrogen which produces most of the observed absorption. The Lyman alpha line is too narrow to account for all of the observed absorption. It was previously known that extra absorption is needed on the blue side of the main H I near to the expected position of deuterium. The current data suggests with a 98% confidence level that the extra absorption is not deuterium. Some uncertainty persists because we have a low signal to noise ratio and the extra absorption - be it deuterium or hydrogen - is heavily blended with the Lyman alpha absorption from the main hydrogen component.

Motivation & Objective

  • To determine whether the anomalous blueward absorption in the Lyα profile of QSO PG1718+4807 is deuterium, which could yield a high primordial D/H ratio.
  • To resolve conflicting interpretations of previous HST GHRS spectra that suggested D/H ≈ 20×10⁻⁵.
  • To assess whether the absorption structure is consistent with deuterium by comparing velocity shift and line width to expected physical parameters.
  • To evaluate whether the system's complex velocity structure, including redward absorption, invalidates the deuterium interpretation.

Proposed method

  • Acquired high-resolution STIS spectra of the Lyα and Lyman limit region of QSO PG1718+4807 with improved signal-to-noise over prior GHRS data.
  • Fitted the high-order Lyman series lines to precisely determine the main hydrogen absorption profile and its velocity width (b = 22.5 km s⁻¹).
  • Constructed a 2D χ² grid over possible deuterium velocity shift and line width to assess likelihood of deuterium at each point.
  • Compared model fits to observed data, using confidence contours to test whether deuterium with physical parameters (b < 19.2 km s⁻¹, v ≈ -82 km s⁻¹) could explain the blue-side absorption.
  • Evaluated alternative models with multiple hydrogen components, showing they do not improve the likelihood of a deuterium interpretation.
  • Used photoionization and metal line (SiIII, MgII) constraints to estimate a physically plausible upper bound for deuterium line width (b ≤ 19.2 km s⁻¹).

Experimental results

Research questions

  • RQ1Is the blueward absorption feature in the Lyα profile of QSO PG1718+4807 consistent with deuterium absorption at the expected velocity shift of -82 km s⁻¹ relative to hydrogen?
  • RQ2Does the velocity width of the blue-side absorption match the expected thermal width of deuterium, given constraints from SiIII and H I lines?
  • RQ3Can a physically plausible deuterium line with b ≤ 19.2 km s⁻¹ explain the observed absorption profile at 98% confidence?
  • RQ4Is the presence of extra absorption on the red side of the Lyα line consistent with a deuterium interpretation?
  • RQ5Does the complex velocity structure of the system, including multiple components, invalidate the deuterium interpretation?

Key findings

  • The most likely solution for the blue-side absorption has a velocity shift of -75.1 ± 8.8 km s⁻¹ and a line width of b = 27.1 ± 5.2 km s⁻¹, inconsistent with deuterium at the expected -82 km s⁻¹ and broader than physical expectations.
  • A deuterium line with b ≤ 19.2 km s⁻¹ (based on SiIII and H I line widths) is ruled out at 98% confidence, as it lies outside the 74% confidence interval in the 2D parameter space.
  • The probability that the blue-side absorption is deuterium, assuming b = 19.2 km s⁻¹, is less than 2% of the best-fit model, indicating strong statistical preference against deuterium.
  • Even when allowing for multiple hydrogen components, the high-order Lyman series lines constrain the total H I profile so tightly that the deuterium interpretation remains statistically implausible.
  • The presence of redward absorption rules out a simple single-component model and supports a complex, multi-component system that can produce spurious absorption features near the deuterium line.
  • The system cannot yield a measurement of the primordial deuterium abundance due to contamination from complex, non-deuterium absorption structures.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.