Skip to main content
QUICK REVIEW

[Paper Review] New Power to Measure Supernova $ u_e$ with Large Liquid Scintillator Detectors

Ranjan Laha, J. F. Beacom|arXiv (Cornell University)|Dec 29, 2014
Neutrino Physics ResearchPhysics and Astronomy68 references7 citations
TL;DR

This paper demonstrates that large liquid scintillator detectors like JUNO, RENO-50, and LENA can measure supernova electron neutrino ($ackslash{}$nu_e$) spectra with unprecedented precision—better than 40% for total energy and 25% for average energy—enabling discrimination between key supernova model predictions and testing neutrino mixing effects in extreme conditions.

ABSTRACT

We examine the prospects for detecting supernova $ u_e$ in JUNO, RENO-50, LENA, or other approved or proposed large liquid scintillator detectors. The main detection channels for supernova $ u_e$ in a liquid scintillator are its elastic scattering with electrons and its charged-current interaction with the $^{12}$C nucleus. In existing scintillator detectors, the numbers of events from these interactions are too small to be very useful. However, at the 20-kton scale planned for the new detectors, these channels become powerful tools for probing the $ u_e$ emission. We find that the $ u_e$ spectrum can be well measured, to better than $\sim 40\%$ precision for the total energy and better than $\sim 25\%$ precision for the average energy. This is adequate to distinguish even close average energies, e.g., 11 MeV and 14 MeV, which will test the predictions of supernova models. In addition, it will help set constraints on neutrino mixing effects in supernovae by testing non-thermal spectra. Without such large liquid scintillator detectors (or Super-Kamiokande with added gadolinium, which has similar capabilities), supernova $ u_e$ will be measured poorly, holding back progress on understanding supernovae, neutrinos, and possible new physics.

Motivation & Objective

  • To assess the potential of large liquid scintillator detectors (e.g., JUNO, RENO-50, LENA) to measure supernova electron neutrinos ($\nu_e$) with high precision.
  • To address the critical gap in measuring $\nu_e$ spectra, which are poorly constrained in existing detectors despite their importance for understanding core-collapse supernovae.
  • To enable testing of supernova models and neutrino mixing effects by improving sensitivity to $\nu_e$ energy and spectral shape.
  • To demonstrate that 20-kiloton-scale liquid scintillator detectors can achieve sufficient event yields for meaningful $\nu_e$ spectral reconstruction.

Proposed method

  • Uses modified Maxwell-Boltzmann neutrino spectra with average energies of 11–14 MeV for $\nu_e$, assuming 3×10⁵³ erg total energy and 10 kpc distance.
  • Models two primary detection channels: elastic scattering on electrons ($\nu_e + e^- \to \nu_e + e^-$) and charged-current interactions on ¹²C nuclei ($\nu_e + {}^{12}\text{C} \to e^- + {}^{12}\text{N}$).
  • Applies Monte Carlo simulations to estimate event rates and energy spectra for detectors with 20-kiloton fiducial mass.
  • Implements spectral unfolding techniques to reconstruct the incident $\nu_e$ energy spectrum from observed energy deposits.
  • Compares detection sensitivity to existing detectors and Super-Kamiokande with gadolinium, highlighting the advantage of larger mass and improved channel sensitivity.
  • Assesses precision in measuring total $\nu_e$ energy and average energy using statistical error estimation on reconstructed spectra.

Experimental results

Research questions

  • RQ1Can large liquid scintillator detectors like JUNO or LENA measure the total energy and average energy of supernova $\nu_e$ with better than 40% and 25% precision, respectively?
  • RQ2Can these detectors distinguish between $\nu_e$ spectra with close average energies, such as 11 MeV and 14 MeV, which are predicted by different supernova models?
  • RQ3To what extent can such detectors constrain neutrino mixing effects in supernovae by probing non-thermal spectral shapes?
  • RQ4How do the detection sensitivities of these large detectors compare to existing scintillators and Super-Kamiokande with gadolinium?
  • RQ5What is the role of the $\nu_e + {}^{12}\text{C} \to e^- + {}^{12}\text{N}$ channel in enabling high-precision $\nu_e$ measurements in large-scale liquid scintillators?

Key findings

  • The total energy of supernova $\nu_e$ can be measured with a precision better than 40% in 20-kiloton-scale liquid scintillator detectors.
  • The average energy of $\nu_e$ can be measured with a precision better than 25%, enabling discrimination between models with 11 MeV and 14 MeV average energies.
  • The $\nu_e$ spectrum can be reconstructed with sufficient fidelity to test for non-thermal features, which are signatures of neutrino mixing in supernovae.
  • The $\nu_e + {}^{12}\text{C} \to e^- + {}^{12}\text{N}$ charged-current interaction provides a new, powerful channel for $\nu_e$ detection in large liquid scintillators, significantly enhancing sensitivity.
  • These detectors can achieve spectral resolution comparable to Super-Kamiokande with gadolinium, but with much larger fiducial mass, leading to improved statistical precision.
  • Without such large detectors or Super-Kamiokande with gadolinium, $\nu_e$ measurements will remain too imprecise to advance understanding of supernovae and neutrino physics.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.