Skip to main content
QUICK REVIEW

[Paper Review] Non-adiabatic Coulomb effects in strong field ionisation in circularly polarised laser fields I: Ionisation rates

Jivesh Kaushal, Olga Smirnova|arXiv (Cornell University)|Feb 11, 2013
Laser-Matter Interactions and ApplicationsPhysics and Astronomy1 citations
TL;DR

This paper extends the analytical R-matrix (ARM) method to model strong-field ionisation in circularly polarised laser fields, incorporating non-adiabatic Coulomb effects for arbitrary atomic potentials. It derives analytical expressions for ionisation rates, corrected ionisation times, initial velocities, momentum shifts, and tunnelling angles, revealing significant modifications to electron dynamics and attoclock calibration due to long-range potential effects.

ABSTRACT

We develop the recently proposed analytical R-matrix (ARM) method to encompass strong field ionisation by circularly polarised fields, for atoms with arbitrary binding potentials. Through ARM, the effect of the potential can now be included consistently both during and after ionisation, providing a complete picture for the effects of the long-range potential. We find that the Coulomb effects modify the ionisation dynamics in several ways, including modification of (i) the ionisation (exit) times, (ii) the initial conditions for the electron continuum dynamics, (iii) the tunnelling angle, at which the electron enters the barrier, and (iv) the electron drift momentum. We derive analytical expressions for the Coulomb-corrected ionisation times, initial velocities, momentum shifts and ionisation rates in circularly polarised fields, for arbitrary angular momentum of the initial state. We also analyse how the non-adiabatic Coulomb effects modify (i) the calibration of the attoclock in the angular streaking method, and (ii) the ratio of ionisation rates from $p^{-}$ and $p^{+}$ orbitals.

Motivation & Objective

  • To develop a consistent theoretical framework for strong-field ionisation in circularly polarised laser fields that includes long-range Coulomb potential effects.
  • To address the limitations of adiabatic approximations in describing electron dynamics during and after ionisation.
  • To derive analytical expressions for ionisation rates, ionisation times, initial velocities, and momentum shifts under non-adiabatic Coulomb effects.
  • To investigate how Coulomb interactions alter the calibration of the attoclock in angular streaking experiments.
  • To examine the ratio of ionisation rates from $p^{-}$ and $p^{+}$ orbitals under circularly polarised light, accounting for non-adiabatic Coulomb corrections.

Proposed method

  • The analytical R-matrix (ARM) method is extended to include strong-field ionisation in circularly polarised laser fields.
  • The method consistently incorporates the binding potential both during and after ionisation, enabling a complete description of long-range Coulomb effects.
  • Analytical solutions are derived for ionisation rates, ionisation times, initial electron velocities, and momentum shifts using the ARM framework.
  • The approach accounts for arbitrary angular momentum in the initial atomic state, enabling application to p-orbitals and other non-s-state systems.
  • The derivation includes the tunnelling angle as a dynamical variable influenced by the Coulomb potential, correcting the standard adiabatic picture.
  • The method is applied to assess how non-adiabatic Coulomb effects affect attoclock calibration and the $p^{-}/p^{+}$ ionisation rate ratio.

Experimental results

Research questions

  • RQ1How do non-adiabatic Coulomb effects modify the ionisation times in circularly polarised strong-field ionisation?
  • RQ2In what way do Coulomb interactions alter the initial conditions for electron continuum dynamics post-ionisation?
  • RQ3How does the Coulomb potential influence the tunnelling angle at which the electron exits the potential barrier?
  • RQ4To what extent do Coulomb effects shift the electron's drift momentum in circularly polarised fields?
  • RQ5How do non-adiabatic Coulomb corrections affect the calibration of the attoclock in angular streaking experiments?

Key findings

  • The ionisation times are corrected by non-adiabatic Coulomb effects, deviating from the standard adiabatic prediction due to long-range potential interactions.
  • Initial electron velocities after ionisation are shifted by Coulomb forces, altering the starting point of continuum dynamics.
  • The tunnelling angle—the direction at which the electron exits the barrier—is modified by the Coulomb potential, affecting the electron's trajectory.
  • Electron drift momentum is systematically shifted due to non-adiabatic Coulomb interactions, with implications for momentum spectroscopy.
  • The ratio of ionisation rates from $p^{-}$ and $p^{+}$ orbitals is modified by Coulomb effects, breaking the symmetry expected in the adiabatic limit.
  • The attoclock calibration is found to be sensitive to non-adiabatic Coulomb corrections, necessitating re-evaluation of angular streaking measurements.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.