[Paper Review] Non-contact photoplethysmogram and instantaneous heart rate estimation from infrared face video

Natalia Martínez, Martín Bertrán|arXiv (Cornell University)|Feb 14, 2019
Non-Invasive Vital Sign MonitoringEngineering18 references3 citations
TL;DR

This paper proposes a non-contact method to estimate instantaneous heart rate (iHR) from infrared (IR) face video using spatiotemporal signal decomposition and time-frequency analysis. It achieves sub-second iHR estimation with low error (RMSE ≤5.61 bpm at 1s intervals) by extracting photoplethysmographic signals from IR video under low-light conditions, demonstrating IR as a viable alternative to visible-light methods.

ABSTRACT

Extracting the instantaneous heart rate (iHR) from face videos has been well studied in recent years. It is well known that changes in skin color due to blood flow can be captured using conventional cameras. One of the main limitations of methods that rely on this principle is the need of an illumination source. Moreover, they have to be able to operate under different light conditions. One way to avoid these constraints is using infrared cameras, allowing the monitoring of iHR under low light conditions. In this work, we present a simple, principled signal extraction method that recovers the iHR from infrared face videos. We tested the procedure on 7 participants, for whom we recorded an electrocardiogram simultaneously with their infrared face video. We checked that the recovered signal matched the ground truth iHR, showing that infrared is a promising alternative to conventional video imaging for heart rate monitoring, especially in low light conditions. Code is available at https://github.com/natalialmg/IR_iHR

Motivation & Objective

  • To develop a non-invasive, non-contact method for estimating instantaneous heart rate (iHR) from infrared (IR) face video.
  • To overcome limitations of visible-light PPG methods, such as dependence on ambient illumination and motion sensitivity.
  • To evaluate the feasibility of using IR video for high-temporal-resolution iHR estimation under controlled motion conditions.
  • To validate the method against ECG and contact PPG ground truth in a controlled setting with healthy subjects.

Proposed method

  • Face regions in IR video are segmented using a 5×5 non-overlapping pixel grid, and mean IR intensity is computed per region to form a data matrix Y₀.
  • Each regional time series is bandpass-filtered (24–300 bpm) using a 5th-order Butterworth filter to isolate physiological signals.
  • Low-rank matrix decomposition (SVD) is applied to Y to extract dominant physiological sources, with singular vectors used to reconstruct a non-contact PPG signal.
  • A signal quality index based on singular value ratios is used to select and combine the most relevant components for final PPG estimation.
  • Time-frequency analysis via short-time Fourier transform (STFT) is applied to the reconstructed PPG signal to extract the dominant frequency curve.
  • The instantaneous heart rate is derived from the dominant curve in the STFT, with frequency tracked over time to yield iHR at each time point.

Experimental results

Research questions

  • RQ1Can infrared face video be used to reliably estimate instantaneous heart rate with sub-second temporal resolution?
  • RQ2How does the performance of IR-based iHR estimation compare to ECG ground truth under controlled motion and low-light conditions?
  • RQ3To what extent can spatiotemporal decomposition and time-frequency analysis extract hemodynamic signals from IR video without contact?
  • RQ4What is the impact of signal quality metrics on the accuracy of iHR estimation from IR video?

Key findings

  • The method achieved a mean RMSE of 3.88 bpm at 1-second intervals across 9 datasets, with individual subject RMSE ranging from 2.21 to 5.61 bpm.
  • Relative error was consistently low, with mean values of 2.28% at 1-second intervals and 1.56% at 30-second intervals.
  • For dataset 8, the RMSE was only 3.30 bpm at 1s intervals and dropped to 0.23% at 30s intervals, indicating high stability over longer windows.
  • Spectrograms of the reconstructed IR PPG showed strong correspondence with the ECG-derived iHR, confirming accurate frequency tracking.
  • The method demonstrated robustness in low-light conditions, highlighting IR’s advantage over visible-light PPG in variable illumination.
  • The use of SVD-based decomposition and signal quality metrics enabled reliable extraction of hemodynamic signals from IR video without contact.