Skip to main content
QUICK REVIEW

[Paper Review] Non-invasive Deep-Brain Imaging with 3D Integrated Photoacoustic Tomography and Ultrasound Localization Microscopy (3D-PAULM)

Yuqi Tang, Zhijie Dong|PubMed|Jul 27, 2023
Photoacoustic and Ultrasonic ImagingEngineering33 references4 citations
TL;DR

This paper presents 3D-PAULM, a non-invasive, integrated imaging system combining photoacoustic computed tomography (PACT) and ultrasound localization microscopy (ULM) for deep-brain hemodynamic imaging in mice. Using a 4 MHz ultrasound frequency, it enables whole-brain functional mapping with intrinsic co-registration of oxygen saturation, blood flow velocity, perfusion, and vessel density, demonstrating stroke-induced ischemia and hypoxia in vivo without removing the scalp or skull.

ABSTRACT

Photoacoustic computed tomography (PACT) is a proven technology for imaging hemodynamics in deep brain of small animal models. PACT is inherently compatible with ultrasound (US) imaging, providing complementary contrast mechanisms. While PACT can quantify the brain's oxygen saturation of hemoglobin (sO<sub>2</sub>), US imaging can probe the blood flow based on the Doppler effect. Further, by tracking gas-filled microbubbles, ultrasound localization microscopy (ULM) can map the blood flow velocity with sub-diffraction spatial resolution. In this work, we present a 3D deep-brain imaging system that seamlessly integrates PACT and ULM into a single device, 3D-PAULM. Using a low ultrasound frequency of 4 MHz, 3D-PAULM is capable of imaging the whole-brain hemodynamic functions with intact scalp and skull in a totally non-invasive manner. Using 3D-PAULM, we studied the mouse brain functions with ischemic stroke. Multi-spectral PACT, US B-mode imaging, microbubble-enhanced power Doppler (PD), and ULM were performed on the same mouse brain with intrinsic image co-registration. From the multi-modality measurements, we future quantified blood perfusion, sO<sub>2</sub>, vessel density, and flow velocity of the mouse brain, showing stroke-induced ischemia, hypoxia, and reduced blood flow. We expect that 3D-PAULM can find broad applications in studying deep brain functions on small animal models.

Motivation & Objective

  • To develop a non-invasive, whole-brain imaging platform for deep-brain hemodynamic function in small animal models.
  • To overcome limitations of existing techniques by integrating PACT and ULM into a single, co-registered system.
  • To enable simultaneous quantification of oxygen saturation (sO₂), blood flow velocity, perfusion, and vessel density in the intact mouse brain.
  • To study functional changes in the brain during ischemic stroke using multi-modal, non-invasive imaging.

Proposed method

  • Integration of photoacoustic computed tomography (PACT) and ultrasound localization microscopy (ULM) into a single 3D imaging system, 3D-PAULM.
  • Use of a low-frequency 4 MHz ultrasound transducer to enable deep penetration through intact scalp and skull.
  • Multi-spectral PACT for quantification of hemoglobin oxygen saturation (sO₂) using multiple laser wavelengths.
  • Ultrasound B-mode imaging for anatomical reference and structural visualization.
  • Microbubble-enhanced power Doppler and ULM for sub-diffraction resolution mapping of blood flow velocity.
  • Intrinsic image co-registration across all modalities to enable direct comparison of hemodynamic parameters.

Experimental results

Research questions

  • RQ1Can a single, non-invasive imaging system simultaneously map oxygenation, perfusion, and blood flow velocity in the deep mouse brain with intact skull and scalp?
  • RQ2How does 3D-PAULM resolve hemodynamic changes during ischemic stroke in vivo?
  • RQ3To what extent does the integration of PACT and ULM improve functional resolution and specificity compared to individual modalities?
  • RQ4Can ULM achieve sub-diffraction resolution flow mapping in deep brain regions using low-frequency ultrasound?
  • RQ5What are the quantitative changes in sO₂, perfusion, and flow velocity in the mouse brain following induced ischemic stroke?

Key findings

  • 3D-PAULM successfully imaged whole-brain hemodynamic functions in mice with intact scalp and skull using a 4 MHz ultrasound frequency.
  • Multi-spectral PACT enabled accurate quantification of hemoglobin oxygen saturation (sO₂), revealing hypoxia in ischemic regions.
  • Ultrasound localization microscopy (ULM) achieved sub-diffraction resolution mapping of blood flow velocity, detecting significant reductions in flow after stroke.
  • Perfusion and vessel density were quantitatively reduced in the ischemic hemisphere, consistent with stroke-induced microvascular dysfunction.
  • Intrinsic co-registration of PACT, B-mode, power Doppler, and ULM data enabled direct correlation of structural, functional, and hemodynamic parameters across the same brain volume.
  • The system demonstrated the ability to non-invasively detect and quantify ischemia, hypoxia, and reduced blood flow in a mouse model of ischemic stroke.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.