[Paper Review] Observation of the prior earthquake effect on the flux of environmental neutrons, gamma-radiation, and on the local electric field in Tien Shan mountain
This study investigates seismic precursors by monitoring environmental neutrons, gamma radiation, and local electric fields at the Tien Shan Cosmic Ray Station. It identifies correlated anomalies in neutron flux, gamma radiation, and electric field intensity up to 3 days before a 5.4 M earthquake, suggesting a potential multi-parameter approach for short-term earthquake forecasting with observed coherence in pre-seismic signals.
A search for the possible precursors of an earthquake and its effect on the data series of diverse geophysical parameters has been made in the mountain of Northern Tien Shan. The complex installation included the NM64 type neutron supermonitor, detectors of the environmental low-energy neutrons, the scintillation gamma-detector, the sensor of the local electric field, a seismograph, and a weather-station. The specialized data filtration methodic was elaborated with an enhanced sensitivity to the transient signals of seismic origin. On the eve of, and after a 5.4 magnitude earthquake the fine features in temporal behavior of the intensity of low-energy neutron and gamma-radiation background, so as irregularities of the local electric field were observed which seem to be in a close correlation with each other. These results may be an evidence of the possibility of experimental identification of earthquake's precursors in the time up to 2-3 days before the beginning of a period of intensive tectonic activity.
Motivation & Objective
- To detect and analyze potential geophysical precursors to strong earthquakes using multi-parameter monitoring.
- To investigate the correlation between environmental neutron flux, gamma radiation, and local electric field variations prior to seismic events.
- To assess the feasibility of using transient signals in these geophysical parameters for short-term earthquake prediction.
- To validate the hypothesis that stress accumulation in the crust induces measurable changes in low-energy neutron and radiation fluxes and atmospheric electric fields.
Proposed method
- Deployment of a multi-sensor complex including NM64 neutron supermonitor, low-energy neutron detectors, NaI scintillation gamma detector, electric field sensor, seismograph, and weather station at Tien Shan Mountain.
- Application of a specialized data filtration technique to enhance sensitivity to transient, seismic-origin signals.
- Use of 50-point moving average filtering to extract diurnal oscillation envelopes from neutron intensity data.
- Comparison of auto-correlation functions of filtered neutron signals with seismic event timing to detect signal coherence.
- Simultaneous monitoring of electric field spikes and gamma radiation dips to identify pre-seismic anomalies.
- High-resolution analysis of electric field pulses to distinguish them from thunderstorm or atmospheric interference.
Experimental results
Research questions
- RQ1Can anomalies in environmental neutron flux, gamma radiation, and local electric field be detected in the days preceding a significant earthquake?
- RQ2To what extent are these anomalies temporally correlated with the onset of seismic activity?
- RQ3Do the observed anomalies in neutron and gamma radiation exhibit coherent patterns with changes in the local electric field prior to an earthquake?
- RQ4Can these geophysical signals be distinguished from natural atmospheric or cosmic background variations?
- RQ5Is there a consistent time window—such as 2–3 days—during which these anomalies emerge before a major seismic event?
Key findings
- A significant decrease in low-energy neutron flux and gamma radiation intensity was observed in the 2–3 days preceding the 5.4 M earthquake on 1 May 2011.
- The auto-correlation function of the filtered neutron signal showed a peak correlation coefficient of approximately 0.65 in the period immediately before the main shock.
- Unidirectional, positive-polarity electric field spikes, each lasting 3–5 seconds and with amplitude ~six times below typical lightning discharges, were detected in the pre-earthquake phase.
- These electric field pulses ceased 40 minutes before the main shock and reappeared only during the strongest aftershock, indicating a strong temporal link to seismic activity.
- The anomalies in neutron flux, gamma radiation, and electric field were highly synchronized, with the most intense electric activity coinciding with the lowest neutron and gamma radiation levels.
- The absence of infrasound or thunderstorm activity during the pre-earthquake period rules out atmospheric interference as the source of the observed electric field pulses.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.