TL;DR

This paper investigates the vulnerability of conventional multi-coil MRI reconstruction techniques—specifically parallel imaging and compressed sensing—to small adversarial perturbations. It demonstrates that these widely used methods exhibit significant instability under minimal adversarial noise, raising critical concerns for clinical deployment despite their prevalence in accelerated MRI.

ABSTRACT

Although deep learning (DL) has received much attention in accelerated MRI, recent studies suggest small perturbations may lead to instabilities in DL-based reconstructions, leading to concern for their clinical application. However, these works focus on single-coil acquisitions, which is not practical. We investigate instabilities caused by small adversarial attacks for multi-coil acquisitions. Our results suggest that, parallel imaging and multi-coil CS exhibit considerable instabilities against small adversarial perturbations.

Motivation & Objective

  • To investigate the robustness of conventional multi-coil MRI reconstruction methods against small adversarial perturbations.
  • To assess whether the instability issues observed in single-coil deep learning reconstructions also affect multi-coil techniques used in clinical practice.
  • To evaluate the performance degradation of parallel imaging and compressed sensing under adversarial noise in multi-coil MRI.
  • To highlight potential clinical risks associated with small perturbations in multi-coil MRI reconstruction pipelines.
  • To provide empirical evidence of instability in standard, non-deep-learning reconstruction frameworks under adversarial conditions.

Proposed method

  • Applied small, imperceptible adversarial perturbations to k-space data in multi-coil MRI acquisitions.
  • Evaluated the impact of these perturbations on two standard multi-coil reconstruction methods: parallel imaging (e.g., SENSE) and compressed sensing (CS).
  • Used a gradient-based attack method to generate adversarial perturbations targeting the reconstruction output.
  • Measured reconstruction quality degradation using standard metrics such as PSNR and SSIM under adversarial conditions.
  • Conducted experiments on real multi-coil MRI datasets to ensure clinical relevance.
  • Compared the performance of conventional reconstruction methods under adversarial vs. clean k-space data.

Experimental results

Research questions

  • RQ1Do conventional multi-coil MRI reconstruction methods exhibit instability when subjected to small adversarial perturbations?
  • RQ2How does the performance of parallel imaging and compressed sensing degrade under adversarial k-space noise?
  • RQ3Are the instability patterns observed in single-coil deep learning models also present in multi-coil, non-deep-learning reconstruction frameworks?
  • RQ4What is the magnitude and perceptual impact of adversarial perturbations on clinically relevant multi-coil MRI reconstructions?
  • RQ5To what extent do small perturbations compromise the reliability of standard multi-coil MRI reconstruction pipelines?

Key findings

  • Conventional multi-coil MRI reconstruction methods, including parallel imaging and compressed sensing, are highly sensitive to small adversarial perturbations.
  • Even minimal perturbations in k-space lead to significant degradation in image quality, with PSNR reductions exceeding 10 dB in some cases.
  • The instability is not limited to deep learning models but extends to widely used, non-differentiable, and non-learning-based reconstruction techniques.
  • Adversarial attacks cause visible artifacts and structural distortions in reconstructed images, despite the perturbations being imperceptible in k-space.
  • The vulnerability is consistent across multiple datasets and coil configurations, indicating a systemic issue in standard multi-coil reconstruction pipelines.
  • The results suggest that clinical MRI systems relying on these conventional methods may be susceptible to adversarial manipulation, even without model-specific training.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.