[Paper Review] On Stokes polarimeters for high precision CMB measurements and mm Astronomy measurements
This paper presents a detailed physical model of Stokes polarimeters for high-precision CMB and mm-wave astronomy, accounting for temperature-dependent optical non-idealities, multiple internal reflections, and polarized emissions from waveplates and polarizers. It demonstrates that cooling components to 1–4 K and minimizing radiative background below 4.5 K is essential to suppress spurious 4f signals that contaminate the cosmological polarization measurement.
Several on-going and future experiments use a Stokes polarimeter (i.e. a rotating wave plate followed by a steady polarizer and by an unpolarized detector) to measure the small polarized component of the Cosmic Microwave Background. The expected signal is typically evaluated using the Mueller formalism. In this work we carry-out the signal evaluation taking into account the temperatures of the different optical devices present in the instrument, their non- idealities, multiple internal reflections, and reflections between different optical components. This analysis, which exploits a new description of the radiation transmitted by a half wave plate, can be used to optimize the experimental setup as well as each of its optical components. We conclude with an example of application of our analysis, studying a cryogenic polarization modulator developed for detecting the interstellar dust polarization.
Motivation & Objective
- Address the challenge of spurious signals in high-precision CMB polarization measurements due to non-ideal optical components.
- Model the impact of temperature-dependent birefringence, multiple internal reflections, and polarized emission from waveplates and polarizers.
- Quantify how thermal emission and optical imperfections generate spurious signals at 2f and 4f modulation frequencies.
- Optimize experimental design by identifying critical cooling requirements for waveplates and polarizers to minimize signal contamination.
- Provide a framework for minimizing detector non-linearity by controlling background radiation levels below 4.5 K.
Proposed method
- Develop a new Mueller matrix formalism that accounts for optically active multiple reflections (OAMR) in birefringent half-wave plates (HWP) at normal incidence.
- Incorporate frequency-dependent refractive indices (ne, no) and temperature-dependent absorption and transmission coefficients in the HWP model.
- Construct separate Mueller matrices for transmitted and reflected radiation, including off-diagonal terms from multiple reflections.
- Simulate the total detected power in a Stokes polarimeter by summing contributions from CMB polarization, unpolarized background (2.7 K), and polarized emissions from HWP (50 K) and polarizer (2.5 K).
- Model detector saturation effects by analyzing non-linear response to large 2f spurious signals, which generate 4f components.
- Propose a solution using an array of polarizers with different wire grid orientations to cancel phase-shifted spurious signals.
Experimental results
Research questions
- RQ1How do temperature-dependent optical properties and multiple internal reflections in a half-wave plate affect the Mueller matrix and signal fidelity in a Stokes polarimeter?
- RQ2What are the dominant sources of spurious signals at 2f and 4f frequencies in a real polarimeter, and how do they contaminate the CMB polarization measurement?
- RQ3To what extent does detector non-linearity amplify spurious 4f signals when large 2f components are present?
- RQ4What are the required cooling temperatures for the HWP and polarizer to reduce spurious signals to acceptable levels below the CMB signal (0.7 μK rms)?
- RQ5Can array-based polarizer configurations with varying orientations mitigate phase-shifted spurious signals through cancellation?
Key findings
- A real HWP at 150 GHz exhibits a non-ideal Mueller matrix with off-diagonal terms (e.g., M34 = 0.033), absent in the ideal case, due to multiple internal reflections.
- Polarized emission from the HWP at 50 K produces a 2f spurious signal of 22 mK, while reflection by the polarizer generates a 4f signal of 3 μK.
- At 2.5 K, the polarized emission from the polarizer reflected by the HWP produces a 4f spurious signal of 2.1 μK, which is 4 times the amplitude of the CMB signal (0.7 μK rms).
- Cooling the polarizer to 1 K reduces the 4f spurious signal to less than 4% of the CMB signal, demonstrating the necessity of deep cooling.
- The radiative background must be kept below 4.5 K to ensure detector linearity and maintain 10% accuracy in measuring S1 and S2 parameters.
- The Cryogenic Waveplate Rotator (CWR) for PILOT achieves sub-0.03° positional accuracy via a room-temperature step motor and 3-bit optical encoder, enabling precise 4f modulation at 4 K.