Skip to main content
QUICK REVIEW

[Paper Review] On the Darwin-Howie-Whelan equations for the scattering of fast electrons described by the Schr\"odinger equation

Thomas Koprucki, Anieza Maltsi|arXiv (Cornell University)|Dec 21, 2020
Electron and X-Ray Spectroscopy TechniquesMaterials Science27 references4 citations
TL;DR

This paper provides a rigorous mathematical analysis of the Darwin-Howie-Whelan (DHW) equations for fast electron scattering in transmission electron microscopy (TEM), deriving error estimates for finite-beam approximations. It establishes that the systematic-row approximation with 18 beams achieves 7 significant digits of accuracy, significantly outperforming the two-beam model, which retains only one significant digit, and demonstrates the necessity of including beams above and below the Ewald sphere for high-precision simulations in applications like electron holography.

ABSTRACT

The Darwin-Howie-Whelan equations are commonly used to describe and simulate the scattering of fast electrons in transmission electron microscopy. They are a system of infinitely many envelope functions, derived from the Schr\"odinger equation. However, for the simulation of images only a finite set of envelope functions is used, leading to a system of ordinary differential equations in thickness direction of the specimen. We study the mathematical structure of this system and provide error estimates to evaluate the accuracy of special approximations, like the two-beam and the systematic-row approximation.

Motivation & Objective

  • To provide a mathematical foundation for the Darwin-Howie-Whelan (DHW) equations used in TEM simulations.
  • To analyze the accuracy of finite-beam approximations, such as the two-beam and systematic-row models, in the context of the full infinite-beam system.
  • To quantify the error introduced by truncating the infinite system of envelope functions in the DHW equations.
  • To establish theoretical error bounds that validate or challenge common beam selection heuristics in multi-beam simulations.
  • To guide the selection of beam sets in quantitative TEM applications requiring high accuracy, such as electron holography.

Proposed method

  • Derives the DHW equations from the time-independent Schrödinger equation under the column approximation, decomposing the wave function into envelope functions ψg(z) modulated in thickness direction.
  • Models the system as a first-order ordinary differential equation in z, with a Hamiltonian structure due to the Hermitian nature of the interaction operator.
  • Introduces error estimates based on the scattering length and system parameters, using |α*k0|⁻² and α*z*/ℓ²_scatt as small perturbation terms.
  • Compares numerical solutions across different beam sets G (e.g., G1 to G4) to assess convergence and accuracy, using the largest set (G4) as a reference.
  • Employs the Ewald sphere criterion to select beams near the sphere, where excitation errors are minimized and amplitudes are maximized.
  • Validates theoretical error bounds against numerical simulations using Julia, with beam amplitudes and excitation errors visualized and quantified.

Experimental results

Research questions

  • RQ1What is the mathematical structure of the DHW equations when truncated to a finite set of beams?
  • RQ2How accurate is the two-beam approximation compared to the full infinite-beam system in predicting electron beam amplitudes?
  • RQ3To what extent does the systematic-row approximation (gz = 0) capture the correct beam amplitudes, and when is it insufficient?
  • RQ4What is the impact of including beams above and below the Ewald sphere on the accuracy of the solution?
  • RQ5Can theoretical error bounds be validated numerically, and how do they inform beam selection in practical TEM simulations?

Key findings

  • The two-beam approximation (G1) achieves only one significant digit of accuracy in the (0,0) and (1,0) mode amplitudes, making it a very rough approximation.
  • The systematic-row approximation with four beams (G2) improves accuracy to four significant digits, and increasing to six beams (G3) does not further improve accuracy.
  • Including beams above and below the Ewald sphere (G4 with 18 beams) increases accuracy to seven significant digits, demonstrating the necessity of such extensions.
  • The reference solution using the full beam set G achieves 7 significant digits, and G4 matches this level, validating its use for high-precision simulations.
  • The theoretical error bounds |α*k0|⁻² ≈ 8.46e-6 and α*z*/ℓ²_scatt ≈ 0.017 are small, confirming the validity of the approximations for the chosen setup.
  • The beam selection strategy in pyTEM—using systematic-row with |Ug| ≥ umin and |sg| ≤ es*—is validated as effective, as it captures the same beam range as G3.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.