Skip to main content
QUICK REVIEW

[Paper Review] On the oxygen abundance determination in HII regions: the problem of the line intensities -- oxygen abundance calibration

L. S. Pilyugin|arXiv (Cornell University)|Apr 4, 2000
Laser-induced spectroscopy and plasmaEngineering5 citations
TL;DR

This paper proposes the p-method, a new calibration for oxygen abundance in HII regions using the excitation parameters p₂ and p₃ derived from [OII]λλ3727,3729 and [OIII]λλ4959,5007 line intensities, which account for variations in physical conditions. The method achieves oxygen abundance determinations as accurate as the temperature-sensitive Tₑ method, especially in low-metallicity regions, and provides a more reliable alternative to the traditional R₂₃ method, reducing systematic errors by ~0.07 dex compared to older calibrations like Edmunds & Pagel (1984).

ABSTRACT

The problem of the line intensities -- oxygen abundance calibration has been considered. We confirm the idea of McGaugh (1991) that the strong oxygen lines ([OII] 3727, 3729 and [OIII] 4959, 5007) contain the necessary information for determination of accurate abundances in low-metallicity (and may be also in high-metallicity) HII regions. It has been found that the excitation parameters p3 or p2 (which are defined here as contributions of the radiation in [OIII] 4959, 5007 lines and in [OII] 3727, 3729 lines to the "total" oxygen radiation respectively) allow to take into account the variations in R23 values among HII regions with a given oxygen abundance. Based on this fact a new way of the oxygen abundance determination in HII regions has been constructed and corresponding relations between line intensities and the oxygen abundance have been derived empirically using the available oxygen abundances determined via measurement of temperature-sensitive line ratios. In parallel a new R23 calibration has been derived on the base of recent data and compared to previous calibrations. For oxygen-rich HII regions the present R23 calibration is close to that of Edmunds and Pagel (1984): their calibration has the same slope but is shifted towards higher oxygen abundances by around 0.07 dex as compared to the present calibration.

Motivation & Objective

  • To address systematic errors in oxygen abundance determination using the R₂₃ method, which fails to account for variations in physical conditions across HII regions.
  • To develop a new calibration method that incorporates excitation parameters (p₂ and p₃) to improve accuracy in low- and high-metallicity HII regions.
  • To derive a new R₂₃ calibration based on recent, high-quality Tₑ-method abundance data, improving consistency with direct temperature-based measurements.
  • To validate the new p-method against the Tₑ method, demonstrating its reliability in low-metallicity environments where Tₑ lines are undetectable.
  • To resolve discrepancies between R₂₃-based and Tₑ-based oxygen abundance determinations by accounting for differences in line excitation.

Proposed method

  • The p-method defines excitation parameters p₂ and p₃ as the fractional contributions of [OII]λλ3727,3729 and [OIII]λλ4959,5007 lines to the total oxygen line radiation.
  • Empirical relations between p₂, p₃, and oxygen abundance (12 + log(O/H)) are derived using a sample of HII regions with Tₑ-method abundances.
  • The method uses observed line intensities to compute p₂ and p₃, which are then used to predict oxygen abundance without relying on temperature-sensitive lines.
  • A new R₂₃ calibration is derived from the same Tₑ-method data, with improved accuracy and reduced systematic offset compared to previous calibrations.
  • The p-method is validated by comparing its abundance results with Tₑ-method results in low-metallicity HII regions and in NGC2403.
  • The method is applied to HII regions across spiral and irregular galaxies, including high-quality data from Shaver et al. (1983), Izotov & Thuan, and Garnett et al. (1997).

Experimental results

Research questions

  • RQ1Can the excitation parameters p₂ and p₃ effectively account for variations in R₂₃ values at a given oxygen abundance across different HII regions?
  • RQ2Does the p-method produce oxygen abundance determinations as accurate as the Tₑ method, especially in low-metallicity environments?
  • RQ3How does the new R₂₃ calibration compare to previous calibrations (e.g., Edmunds & Pagel 1984) in terms of slope and zero-point offset?
  • RQ4To what extent does the p-method reduce systematic errors compared to the standard R₂₃ method in oxygen-rich HII regions?
  • RQ5Is the p-method robust enough to replace the R₂₃ method in abundance studies where Tₑ lines are undetectable?

Key findings

  • The p-method achieves oxygen abundance determinations with accuracy comparable to the Tₑ method in low-metallicity HII regions, where temperature-sensitive lines are undetectable.
  • The excitation parameters p₂ and p₃ effectively account for variations in R₂₃ at a fixed oxygen abundance, reducing systematic errors in abundance calibration.
  • The new R₂₃ calibration has the same slope as Edmunds & Pagel (1984) but is shifted by approximately -0.07 dex toward lower oxygen abundances.
  • The p-method reduces the discrepancy between R₂₃-based and Tₑ-based abundances, especially in low-metallicity regions, where R₂₃-based values can differ by up to 0.3 dex.
  • For oxygen-rich HII regions, the p-method performs as well as the Tₑ method, based on indirect evidence and consistency with NGC2403 radial abundance profiles.
  • The calibration of Edmunds & Pagel (1984) is found to be systematically offset by ~0.07 dex higher than the new calibration, explaining past discrepancies in abundance comparisons.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.