[Paper Review] Optimal Storage and Solar Capacity of a Residential Household under Net Metering and Time-of-Use Pricing
This paper proposes an analytical framework to jointly optimize solar PV and battery storage capacity for residential households under net metering with time-of-use (ToU) pricing. Using real Austin, TX data, it derives optimal storage (36.96 kWh) and solar (up to 5 kWp) capacity, showing 25.56% cost savings including capital costs and up to 41.7% savings with optimal solar investment.
Incentive programs and ongoing reduction in costs are driving joint installation of solar PV panels and storage systems in residential households. There is a need for optimal investment decisions to reduce the electricity consumption costs of the households further. In this paper, we first develop analytical expression of storage investment decision and then of solar investment decision for a household which is under net metering billing mechanism with time of use pricing condition. Using real data of a residential household in Austin, TX, USA, we study how the investment decisions would provide benefit for a period of one year. Results show significant profit when using storage devices and solar panels optimally for the system. It is important to note that though our approach can help significantly to take investment decisions, the solution will still be sub-optimal for somebody who needs optimal investment jointly on both storage and solar systems.
Motivation & Objective
- To determine optimal battery storage capacity for residential households under net metering with time-of-use (ToU) pricing.
- To analyze the impact of solar PV capacity on electricity cost reduction when combined with optimal storage.
- To evaluate cost savings from joint investment in solar and storage under real-world load and irradiance data.
- To identify sub-optimal outcomes when optimizing storage and solar separately rather than jointly.
Proposed method
- Uses kernel density estimation to model the cumulative distribution of daily peak load for optimal storage sizing.
- Derives analytical expressions for optimal storage capacity $B^0$ based on expected energy flow and ToU price differentials.
- Evaluates cost savings across varying solar PV capacities (up to 5 kWp) using monthly load and irradiance data from Austin, TX (2016).
- Calculates total annual cost including capital costs and compares savings with and without storage and solar investment.
- Employs a step-by-step simulation over 366 days to compute monthly electricity costs under different configurations.
- Uses expected energy flow and price differentials to determine optimal investment thresholds for storage and solar.
Experimental results
Research questions
- RQ1What is the optimal battery storage capacity for a residential household under net metering with ToU pricing?
- RQ2How does varying solar PV capacity affect cost savings when paired with optimal storage?
- RQ3What is the total cost reduction achievable through joint optimization of solar and storage, including capital costs?
- RQ4How does the sequential optimization of storage and solar compare to joint optimization in terms of cost efficiency?
- RQ5What is the impact of peak load distribution on determining optimal storage size?
Key findings
- The optimal battery storage capacity is 36.96 kWh, determined by the 96.5th percentile of daily peak load distribution.
- With optimal storage, the household achieves a 25.56% reduction in annual electricity cost, saving $1,027.99 including capital costs.
- For every 0.5 kW increase in solar PV capacity (up to 5 kWp), additional savings of $134 are achieved, with total savings reaching $2,363.82 at 5 kWp.
- The total annual cost drops from $4,021.49 (no solar, no storage) to $1,657.67 with optimal storage and 30 kWp solar (though 30 kWp exceeds typical roof size).
- Joint optimization of solar and storage yields better results than sequential optimization—e.g., at 30 kWp solar, cost drops to $1,612.78 with 24.4 kWh storage, lower than $1,657.67 at 36.96 kWh.
- The method provides a sub-optimal solution when both solar and storage are optimized jointly, indicating room for improved joint optimization models.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.