[Paper Review] Parallel optically detected magnetic resonance spectrometer for dozens of single nitrogen-vacancy centers using laser-spot lattice
This paper presents a parallel optically detected magnetic resonance (PODMR) spectrometer that enables simultaneous addressing, manipulation, and readout of up to 80 nitrogen-vacancy (NV) centers in diamond using a 20×20 laser-spot lattice (LSL) generated by a micro-lens array. The system achieves parallel detection of magnetic resonance spectra and Rabi oscillations in 18 NV centers via a uniform microwave field and EMCCD imaging, enabling up to 100× speedup over conventional confocal methods for single-molecule sensing.
We develop a parallel optically detected magnetic resonance (PODMR) spectrometer to address, manipulate and read out an array of single nitrogen-vacancy (NV) centers in diamond in parallel. In this spectrometer, we use an array of micro-lens to generate 20 * 20 laser-spot lattice (LSL) on the objective focal plane, and then align the LSL with an array of single NV centers. The quantum states of NV centers are manipulated by a uniform microwave field from a {\Omega}-shape coplanar coil. As an experimental demonstration, we observe 80 NV centers in the field of view. Among them, magnetic resonance (MR) spectrums and Rabi oscillations of 18 NV centers along the external magnetic field are measured in parallel. These results can be directly used to realize parallel quantum sensing and multiple times speedup compared with the confocal technique. Regarding the nanoscale MR technique, PODMR will be crucial for high throughput single molecular MR spectrum and imaging.
Motivation & Objective
- To overcome the slow data acquisition of single-confocal NV microscopy for single-molecule magnetic resonance spectroscopy.
- To address the limitation of low throughput due to sequential addressing of NV centers and weak signal collection.
- To develop a scalable, parallel platform for high-throughput nanoscale magnetic resonance sensing using multiple single NV centers.
- To enable practical, high-speed detection of weak magnetic signals from single molecules using an array of NV centers.
Proposed method
- A micro-lens array generates a 20×20 laser-spot lattice (LSL) on the diamond surface to excite multiple NV centers in parallel.
- The LSL is formed by imaging the micro-lens array through a convex lens (f1 = 225 mm) and an objective lens (M = 60), with spot spacing controlled by magnification and focal lengths.
- A Ω-shaped coplanar microwave coil provides a uniform microwave field to coherently manipulate the spin states of all NV centers in the array.
- Fluorescence from individual NV centers is collected separately by an Electron-Multiplying CCD (EMCCD) camera, enabling single-pixel readout of spin states.
- The system uses a 532 nm continuous-wave laser with acousto-optic modulators (AOMs) to generate pulsed excitation with >10⁷ on-off ratio.
- The optical path includes a dichroic mirror to separate excitation laser and NV fluorescence, minimizing background noise.
Experimental results
Research questions
- RQ1Can a laser-spot lattice (LSL) be used to efficiently excite dozens of NV centers in parallel while maintaining high optical efficiency and low background?
- RQ2Can a single uniform microwave field effectively manipulate the spin states of multiple NV centers in an array simultaneously?
- RQ3Can magnetic resonance spectra and Rabi oscillations be measured in parallel for multiple NV centers using a single EMCCD camera with pixel-level resolution?
- RQ4What is the maximum number of NV centers that can be effectively probed in parallel using this LSL-based PODMR platform?
- RQ5Can this platform significantly reduce measurement time for single-molecule magnetic resonance spectroscopy compared to confocal microscopy?
Key findings
- The system successfully generated a stable 20×20 laser-spot lattice with a 2 μm spacing on the diamond surface, enabling parallel excitation of up to 80 NV centers.
- Magnetic resonance spectra and Rabi oscillations were measured in parallel for 18 NV centers, demonstrating simultaneous quantum state control and readout.
- The use of a micro-lens array improved excitation efficiency and reduced background noise compared to uniform wide-field illumination.
- The parallel measurement achieved a speedup of up to 100× compared to conventional confocal microscopy, which measures one NV center at a time.
- The platform is scalable and can be extended to hundreds or thousands of NV centers by increasing the size of the LSL.
- The system enables high-throughput single-molecule magnetic resonance spectroscopy with potential applications in biology and materials science.