Skip to main content
QUICK REVIEW

[Paper Review] Performance Control of Tendon-Driven Endoscopic Surgical Robots With Friction and Hysteresis

Thanh Nho, Tegoeh Tjahjowidodo|arXiv (Cornell University)|Feb 6, 2017
Soft Robotics and ApplicationsEngineering28 references8 citations
TL;DR

This paper proposes an adaptive nonlinear control scheme for tendon-sheath mechanisms (TSMs) in endoscopic surgical robots that compensates for friction and backlash hysteresis without requiring precise knowledge of model parameters or sheath configuration. By online estimating bounds of friction and hysteresis nonlinearities and using a dynamic friction model, the controller achieves significant tracking performance improvement, reducing mean squared error (MSE) from 0.0022 rad² to 2.7876×10⁻⁴ rad² under varying endoscope configurations.

ABSTRACT

In this study, a new position control scheme for the tendon-sheath mechanism (TSM) which is used in flexible medical devices is presented. TSM is widely used in dexterous robotic applications because it can flexibly work in limited space, in constrained environments, and provides efficient power transmission from the external actuator to the distal joint. However, nonlinearities from friction and backlash hysteresis between the tendon and the sheath pose challenges in achieving precise position controls of the end effector. Previous studies on the TSM only address the control problem under the assumptions of known tendon-sheath configuration and known model parameters of the backlash hysteresis nonlinearity. These approaches can have adverse impact and limitations on the overall system performances and practical implementation. This paper presents a new approach to model and control the TSM-driven flexible robotic systems. The designed controller does not require exact knowledge of nonlinear friction and backlash hysteresis parameters, only their bounds are online estimated. Simulation and experimental validation results show that the proposed control scheme can significantly improve the tracking performances without the presence of the exact knowledge of the model parameters and the sheath configuration.

Motivation & Objective

  • To address the challenge of precise position control in tendon-sheath mechanisms (TSMs) used in flexible endoscopic surgical robots.
  • To overcome limitations of prior control methods that require known model parameters and sheath configurations.
  • To develop a robust control scheme that compensates for dynamic friction and backlash hysteresis using only online-estimated bounds of nonlinearities.
  • To validate the controller's performance under varying endoscope configurations and real-world disturbances.
  • To enable practical implementation of TSM-based robotic systems in minimally invasive and natural orifice surgery.

Proposed method

  • The controller uses a novel dynamic friction model for TSMs with fewer parameters, capturing both presliding and sliding regimes.
  • It employs an adaptive control law that estimates upper bounds of friction and hysteresis nonlinearities in real time.
  • The control scheme is designed to be independent of the tendon-sheath configuration and does not require prior knowledge of model parameters.
  • A feedforward compensation mechanism is integrated to counteract the effects of nonlinearities during motion.
  • The controller is validated through simulations and experiments on a physical TSM prototype under varying endoscope configurations.
  • Performance is quantified using mean squared error (MSE) of tracking error across multiple trials.

Experimental results

Research questions

  • RQ1Can a position control scheme for TSMs achieve high-precision tracking without requiring exact knowledge of friction and hysteresis model parameters?
  • RQ2How does the controller perform when the endoscope configuration is changed during operation, introducing unknown friction variations?
  • RQ3To what extent can online estimation of nonlinearity bounds improve tracking performance compared to fixed-parameter controllers?
  • RQ4Can the proposed controller handle both small and large displacement regimes in the presence of dynamic friction and backlash hysteresis?
  • RQ5What is the quantitative improvement in tracking accuracy when using adaptive bounds estimation versus conventional methods?

Key findings

  • The proposed controller significantly reduces tracking error, decreasing the mean squared error (MSE) from 0.0022 rad² to 2.7876×10⁻⁴ rad² under varied endoscope configurations.
  • The controller maintains good tracking performance even when the endoscope configuration is randomly changed during experiments, demonstrating robustness to unknown friction variations.
  • The MSE values across five trials with varied configuration ranged from 1.1921×10⁻⁴ to 3.3967×10⁻⁴ rad², indicating consistent and low error performance.
  • The controller achieves improved performance without relying on known tendon-sheath configuration or exact model parameters, enabling practical deployment.
  • The experimental results confirm that online estimation of nonlinearity bounds is sufficient for high-precision control, eliminating the need for prior calibration of complex models.
  • The controller effectively mitigates steady-state errors and oscillations caused by friction and hysteresis, even in dynamic and changing environments.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.