TL;DR

This paper evaluates the performance of the first LHAASO Water Cherenkov Detector Array (WCDA-1) by observing the Crab Nebula as a standard candle in TeV gamma-ray astronomy. Using 10 months of data, WCDA-1 achieves a sensitivity of 65 mCU per year at 5σ significance, with excellent angular resolution (<0.4° above 3 TeV) and pointing accuracy (<0.05°), validating its design and calibration. The measured spectral energy distribution (SED) of the Crab Nebula shows good agreement with other major experiments across 0.5–15.8 TeV.

ABSTRACT

The first Water Cherenkov detector of the LHAASO experiment (WCDA-1) has been operating since April, 2019. The first 10 months of data have been analyzed to test its performance by observing the Crab Nebula as a standard candle. The WCDA-1 achieves the sensitivity of 65 mCU per year with a statistical threshold of 5 $σ$. In order to do so, 97.7\% cosmic ray background rejection rate around 1 TeV and 99.8\% around 6 TeV with an approximately photon acceptance about 50\% by using the $compactness$ of the shower footprints to be greater than 10 as the discriminator between gamma induced showers and the cosmic ray backgrounds. The angular resolution is measured using the Crab Nebula as a point source about 0.45$^\circ$ at 1 TeV and better than 0.2$^\circ$ above 6 TeV with the pointing accuracy better than 0.05$^\circ$. They are all matching the design specifications. The energy resolution is found 33\% for gamma rays around 6 TeV. The spectral energy distribution of the Crab Nebula in the range from 500 GeV and 15.8 TeV is measured and in agreement with results of other TeV gamma ray observatories.

Motivation & Objective

  • To validate the performance of the first LHAASO Water Cherenkov Detector Array (WCDA-1) using the Crab Nebula as a standard candle in TeV gamma-ray astronomy.
  • To assess the detector's sensitivity, angular resolution, and pointing accuracy through long-term observation of a well-known astrophysical source.
  • To evaluate systematic uncertainties in gamma-ray energy reconstruction and acceptance estimation due to simulation assumptions and detector stability.
  • To calibrate the detector's response using cosmic ray data and validate simulation models against measured shower distributions.
  • To measure the spectral energy distribution (SED) of the Crab Nebula in the 0.5–15.8 TeV range and compare it with results from other major gamma-ray experiments.

Proposed method

  • WCDA-1 collected 10 months of data from April 2019, using 900 photomultiplier tubes (PMTs) to detect Cherenkov light from air showers.
  • Gamma-ray events were reconstructed using a charge-based shower reconstruction method with thresholds of 0.3 PE and 0.6 PE to assess energy scale uncertainty.
  • Detector orientation and timing were precisely calibrated per unit to achieve sub-0.05° pointing accuracy and <0.4° angular resolution above 3 TeV.
  • Air shower and detector simulations were tuned to match observed cosmic ray data, enabling estimation of effective area and gamma-ray acceptance.
  • Systematic uncertainties were quantified by comparing simulation outputs with data using two cosmic ray composition assumptions and analyzing hit distribution discrepancies.
  • The Crab Nebula's SED was reconstructed using energy reconstruction and acceptance corrections, with systematic errors estimated via threshold variation and model comparison.
Figure 1: Schematic of the WCDA layout. The lower two ponds are WCDA-1 and WCDA-2 from left to right, respectively, and the upper one is WCDA-3. The two dots in each detector unit indicate the PMTs, while the dashed lines represent the curtains between units. Two combinations of PMTs are used: 8” an
Figure 1: Schematic of the WCDA layout. The lower two ponds are WCDA-1 and WCDA-2 from left to right, respectively, and the upper one is WCDA-3. The two dots in each detector unit indicate the PMTs, while the dashed lines represent the curtains between units. Two combinations of PMTs are used: 8” an

Experimental results

Research questions

  • RQ1What is the sensitivity of WCDA-1 in detecting TeV gamma rays, and does it meet the design specification?
  • RQ2How accurate is the angular resolution and pointing direction of WCDA-1 for gamma-ray sources above 3 TeV?
  • RQ3To what extent do uncertainties in detector simulation, cosmic ray composition, and shower modeling affect the gamma-ray energy scale and acceptance estimation?
  • RQ4How well does the measured SED of the Crab Nebula from WCDA-1 agree with results from other major gamma-ray observatories?
  • RQ5What is the impact of detector stability and water transparency variations on charge measurement and detection efficiency over 170 operational days?

Key findings

  • WCDA-1 achieved a sensitivity of 65 mCU per year at 5σ significance, consistent with the design specification.
  • The angular resolution for gamma-ray arrival direction is better than 0.4° above 3 TeV, with pointing accuracy better than 0.05°.
  • The spectral energy distribution (SED) of the Crab Nebula was measured from 0.5 TeV to 15.8 TeV, showing good agreement with other major gamma-ray experiments.
  • Systematic uncertainty in the SED is estimated as ${}^{+8}_{-24}$ %, primarily due to uncertainties in shower simulation, cosmic ray composition, and energy scale calibration.
  • A 11% correction was applied to charge measurements due to increasing PMT charge over time, introducing ~8.8% uncertainty at Q=0.3 PE for low-hit events.
  • The discrepancy between two cosmic ray composition assumptions in hit distribution modeling led to a conservative 16% uncertainty in detector efficiency estimation.
Figure 2: A typical high energy shower event detected by WCDA-1. The top left panel shows the arrival time of the shower front at each cell. The units on the colour scale are ns. The top right panel shows the number of photoelectrons, N PE , recorded by the 8” PMT in each cell (bin) in which many sa
Figure 2: A typical high energy shower event detected by WCDA-1. The top left panel shows the arrival time of the shower front at each cell. The units on the colour scale are ns. The top right panel shows the number of photoelectrons, N PE , recorded by the 8” PMT in each cell (bin) in which many sa

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.