[Paper Review] Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c
This paper evaluates the performance of the CMS High Granularity Calorimeter (HGC) prototype using charged pion beams from 20 to 300 GeV/c. It demonstrates that GEANT4 simulations with the QGSP_FTFP_BERT_EMN and FTFP_BERT_EMN physics lists accurately reproduce the detector's energy response, non-linearity, and shower profiles after calibration, achieving a stochastic term of 131.7±1.0% for pions showering in CE-E and 122.1±1.4% for MIP-like pions.
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.
Motivation & Objective
- To assess the energy resolution and response linearity of the CMS High Granularity Calorimeter prototype using charged pion beams across a broad energy range.
- To calibrate the electromagnetic and hadronic sections of the prototype using 50 GeV positrons and pions, respectively, to establish a consistent energy scale.
- To validate the accuracy of GEANT4 simulations using two physics lists (QGSP_FTFP_BERT_EMN and FTFP_BERT_EMN) in reproducing the detector's response to hadronic showers.
- To develop and test an energy-dependent calibration method using χ²-minimization to correct for non-linear response in different calorimeter compartments.
- To compare measured and simulated longitudinal and transverse shower profiles, identifying discrepancies requiring refinement in digitization and electronics modeling.
Proposed method
- Irradiated the HGC prototype with charged pion beams spanning 20–300 GeV/c to measure energy deposition and shower development.
- Fixed the electromagnetic energy scale using 50 GeV positron events and the hadronic scale using 50 GeV pion events.
- Applied energy-dependent calibration weights derived via χ²-minimization using beam energy as a reference to correct non-linear response.
- Used two GEANT4 physics lists—QGSP_FTFP_BERT_EMN and FTFP_BERT_EMN—to simulate hadronic shower development and compare with data.
- Implemented an algorithm to identify the starting point of hadronic showers in the detector using spatial and energy deposition patterns.
- Performed detailed comparisons of transverse and longitudinal shower profiles between data and simulation across CE-E, CE-H, and AHCAL sections.
Experimental results
Research questions
- RQ1How accurately do GEANT4 simulations with QGSP_FTFP_BERT_EMN and FTFP_BERT_EMN physics lists reproduce the energy response of the HGC prototype to pion beams?
- RQ2What is the optimal calibration strategy to correct for non-linear energy response in different calorimeter compartments?
- RQ3How well do the simulations reproduce the longitudinal and transverse shower profiles observed in data?
- RQ4What discrepancies exist between measured and simulated energy deposition near the particle track, and what do they imply about simulation fidelity?
- RQ5Can energy-dependent calibration weights improve resolution compared to fixed-weight methods using beam energy as reference?
Key findings
- The simulated energy response for pions not interacting in CE-E is higher than data by 9.5%, and for pions initiating showers in CE-E by 5%.
- After correcting for the energy scale difference, the non-linearity of the response is well reproduced in simulation.
- The stochastic term for pions showering in CE-E is measured as 131.7±1.0%, and for MIP-like pions as 122.1±1.4% in data.
- The constant terms are 8.5±0.1 for showering pions and 9.0±0.2 for MIP-like pions in data.
- Both physics lists predict the stochastic and constant terms within 8–10% of the measured values.
- Using energy-dependent calibration weights based on beam energy as reference yields resolution comparable or slightly better than fixed-weight methods.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.