Skip to main content
QUICK REVIEW

[Paper Review] Performer: A Novel PPG-to-ECG Reconstruction Transformer for a Digital Biomarker of Cardiovascular Disease Detection

Ella Lan|arXiv (Cornell University)|Apr 25, 2022
Non-Invasive Vital Sign MonitoringEngineering4 citations
TL;DR

This paper proposes Performer, a novel Transformer-based architecture that reconstructs ECG signals from PPG using Shifted Patch-based Attention (SPA), achieving state-of-the-art 0.29 RMSE on the BIDMC dataset. It enables continuous, non-invasive cardiovascular disease (CVD) detection by combining PPG and reconstructed ECG as a multimodal digital biomarker, validated with 95.9% accuracy on MIMIC-III and 75.9% on PPG-BP, and demonstrated via a wearable earring prototype (PEARL).

ABSTRACT

Electrocardiography (ECG), an electrical measurement which captures cardiac activities, is the gold standard for diagnosing cardiovascular disease (CVD). However, ECG is infeasible for continuous cardiac monitoring due to its requirement for user participation. By contrast, photoplethysmography (PPG) provides easy-to-collect data, but its limited accuracy constrains its clinical usage. To combine the advantages of both signals, recent studies incorporate various deep learning techniques for the reconstruction of PPG signals to ECG; however, the lack of contextual information as well as the limited abilities to denoise biomedical signals ultimately constrain model performance. In this research, we propose Performer, a novel Transformer-based architecture that reconstructs ECG from PPG and combines the PPG and reconstructed ECG as multiple modalities for CVD detection. This method is the first time that Transformer sequence-to-sequence translation has been performed on biomedical waveform reconstruction, combining the advantages of both PPG and ECG. We also create Shifted Patch-based Attention (SPA), an effective method to encode/decode the biomedical waveforms. Through fetching the various sequence lengths and capturing cross-patch connections, SPA maximizes the signal processing for both local features and global contextual representations. The proposed architecture generates a state-of-the-art performance of 0.29 RMSE for the reconstruction of PPG to ECG on the BIDMC database, surpassing prior studies. We also evaluated this model on the MIMIC-III dataset, achieving a 95.9% accuracy in CVD detection, and on the PPG-BP dataset, achieving 75.9% accuracy in related CVD diabetes detection, indicating its generalizability. As a proof of concept, an earring wearable named PEARL (prototype), was designed to scale up the point-of-care (POC) healthcare system.

Motivation & Objective

  • Address the limitations of ECG for continuous monitoring due to user participation requirements and the noise in PPG signals for clinical use.
  • Develop a deep learning model that reconstructs high-fidelity ECG from PPG to enable continuous, non-invasive cardiac monitoring.
  • Create a multimodal digital biomarker combining PPG and reconstructed ECG to improve CVD detection performance.
  • Design a wearable prototype (PEARL) to demonstrate real-world applicability of the Performer architecture for point-of-care healthcare.
  • Demonstrate generalizability of the model across diverse datasets, including MIMIC-III and PPG-BP, for CVD and diabetes detection.

Proposed method

  • Propose a sequence-to-sequence Transformer architecture (Performer) for PPG-to-ECG reconstruction, leveraging self-attention mechanisms for long-range dependencies.
  • Introduce Shifted Patch-based Attention (SPA), a novel tokenization method that uses variable-sized patches and a shifted mechanism to capture cross-patch connections and local-global signal features.
  • Optimize the encoding and decoding process by fetching multiple sequence lengths through patch-based representation, enhancing feature extraction from biomedical waveforms.
  • Train the Performer model end-to-end on the BIDMC dataset to minimize reconstruction error (RMSE) between predicted and ground-truth ECG signals.
  • Use the reconstructed ECG and raw PPG as multimodal inputs for downstream CVD detection, employing a multimodal Transformer head for classification.
  • Deploy the model on cloud-connected wearable devices (e.g., PEARL earring) to enable real-time, continuous monitoring and risk prediction.

Experimental results

Research questions

  • RQ1Can a Transformer-based architecture achieve state-of-the-art performance in reconstructing ECG signals from PPG using only the PPG input?
  • RQ2How effective is the proposed Shifted Patch-based Attention (SPA) mechanism in capturing both local and global signal patterns in biomedical waveforms?
  • RQ3Does combining raw PPG and reconstructed ECG as a multimodal digital biomarker improve CVD detection accuracy compared to using either signal alone?
  • RQ4Can the Performer model generalize across diverse clinical datasets, such as MIMIC-III and PPG-BP, for CVD and diabetes detection?
  • RQ5Can a wearable prototype (PEARL) effectively integrate the Performer model for real-time, continuous, and user-friendly cardiac monitoring in point-of-care settings?

Key findings

  • Performer achieves a state-of-the-art reconstruction RMSE of 0.29 on the BIDMC dataset, outperforming prior methods in PPG-to-ECG reconstruction.
  • The model achieves 95.9% accuracy in CVD detection on the MIMIC-III dataset when using the multimodal input of PPG and reconstructed ECG.
  • On the PPG-BP dataset, Performer attains 75.9% accuracy in detecting CVD-related diabetes, demonstrating robustness and generalizability across datasets.
  • Ablation studies confirm that the multimodal combination of PPG and reconstructed ECG yields the highest CVD detection performance, outperforming raw PPG, raw ECG, or reconstructed ECG alone.
  • Attention maps from the final layer highlight focus on the QRS complex, indicating that Performer learns biologically meaningful features through SPA.
  • The PEARL wearable prototype successfully demonstrates the feasibility of deploying Performer in a real-world, continuous, point-of-care cardiac monitoring system.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.