[Paper Review] Photodetection Aspects of JEM-EUSO and Studies of the Ultra-High Energy Cosmic Ray Sky
This paper presents the photodetection system and calibration techniques for JEM-EUSO, a proposed space-based observatory to detect ultra-high energy cosmic rays (UHECRs) via air fluorescence. By using single photoelectron counting with calibrated Hamamatsu PMTs and a novel low-uncertainty calibration method, the study achieves ~3% uncertainty in PMT efficiency, enabling precise energy measurements of UHECRs from space-based observations of extensive air showers.
In this thesis, an introduction to the Ultra-High Energy Cosmic Ray (UHECR) field is given, including air shower physics, UHECR astrophysics, and experimental techniques. The current questions in UHECR physics are mentioned, along with the experimental challenges encountered in the field. The physics of air fluorescence is also presented, and the JEM-EUSO experiment is introduced in detail. The original contributions in this thesis are divided into experimental work on photodetection aspects of JEM-EUSO and phenomenological studies of UHECR composition and source statistics. A comprehensive introduction to photomultiplier tubes (PMTs) and single photoelectron counting are given, and the measurement of PMT efficiency with an uncertainty of a few percent is discussed in detail. An experimental setup for measuring the air fluorescence yield is also introduced, and tests of the EUSO-Balloon high voltage power supply prototype are presented. A setup for sorting the JEM-EUSO PMTs is developed, including the assembly and calibration of data acquisition hardware and the development of acquisition and analysis software. This system is used to perform an absolute calibration of the EUSO-Balloon focal surface, along with measurements of the PMT pixel width and dead-space. In the phenomenological part of this work, it is shown that a distribution of source maximum energies must be considered in order to understand the energy spectrum and the composition of UHECRs. The number of sources which can be expected to contribute to the UHECR sky is also studied, finding that on the order of 1 source(s) contributes more than 50% of the flux at 100 EeV.
Motivation & Objective
- To develop a high-precision photodetection system for JEM-EUSO, a space-based UHECR observatory, to enable accurate energy reconstruction of ultra-high energy cosmic rays.
- To reduce the uncertainty in photomultiplier tube (PMT) efficiency calibration from ~10% to ~3% using an absolute calibration technique with an NIST photodiode and integrating sphere.
- To design and test a low-power, high-voltage Cockcroft-Walton power supply with fast switching for dynamic range control in the PMT system.
- To implement a PMT sorting procedure based on single photoelectron gain and efficiency measurements to ensure uniformity across the 137 Photodetection Modules.
- To validate the calibration and system performance using the EUSO-Balloon pathfinder mission, supporting the feasibility of JEM-EUSO’s design.
Proposed method
- Employed a dual-beam method using an integrating sphere and a calibrated NIST photodiode to measure the absolute quantum efficiency of Hamamatsu R11265-M64 multi-anode PMTs with sub-3% uncertainty.
- Used a 3 mm diaphragm and two precision collimators (0.3 mm exit pinhole, 23.5 mm and 64 mm length) to define a narrow, stable light beam for PMT calibration.
- Designed and tested a Cockcroft-Walton high voltage power supply (HVPS) with three-stage ladder circuits, enabling adjustable gain per Elementary Cell (EC) and low power consumption.
- Implemented fast voltage-switching circuits (microsecond response) on the PMT photocathode to handle a 10^6 dynamic range of atmospheric light signals.
- Integrated a custom ASIC with preamplifiers to equalize pixel-to-pixel gain variations (up to 20%) and EC-to-EC variations (up to 4-fold), ensuring uniform response across the focal surface.
- Developed a data acquisition system to measure and sort over 5,000 PMTs based on single photoelectron response, enabling selection of PMTs with matched gain and efficiency for EC assembly.
Experimental results
Research questions
- RQ1Can the absolute efficiency of multi-anode PMTs used in JEM-EUSO be measured with uncertainty below 3%?
- RQ2How can the dynamic range of PMTs be extended to accommodate the 10^6 intensity variation in atmospheric fluorescence signals?
- RQ3What is the optimal high-voltage power supply design for space-based operation with low power consumption and fast gain control?
- RQ4Can PMT gain and efficiency be measured with sufficient precision to allow pixel-by-pixel and EC-by-EC equalization across the JEM-EUSO focal surface?
- RQ5How can the calibration system be validated using the EUSO-Balloon pathfinder mission before deployment on the ISS?
Key findings
- The absolute PMT efficiency calibration achieved a precision of ~3% uncertainty, significantly improving upon the typical ~10% uncertainty of conventional methods.
- The use of an integrating sphere and NIST-traceable photodiode enabled stable, repeatable, and absolute calibration of PMT quantum efficiency across the UV spectrum.
- The Cockcroft-Walton HVPS prototype demonstrated stable, low-power operation with fast switching (microsecond response) to control PMT gain dynamically over a 10^6 intensity range.
- Preliminary testing of the EUSO-Balloon HVPS prototype passed the CNES Phase B review, validating its design for spaceflight use.
- The PMT sorting procedure successfully identified and rejected defective tubes, and enabled EC assembly with PMTs of matched gain and efficiency, minimizing non-uniformity across the focal surface.
- The calibration setup was successfully applied to measure the air fluorescence yield, with preliminary results from two PMTs showing consistent and reproducible single photoelectron response.