[Paper Review] Physical interpretation of the anomalous Cherenkov rings observed with the DELPHI detector
This paper proposes that anomalous Cherenkov rings observed in the DELPHI RICH detector—exhibiting radii exceeding those of ultrarelativistic particles—originate from faster-than-light tachyons. Using kinematic fitting of ring radii and momentum constraints in liquid and gaseous radiators, the authors identify two distinct tachyon mass peaks at 0.29±0.01 GeV/c² and 4.6±0.2 GeV/c², with strong consistency between liquid and gas radiator measurements supporting a non-background origin.
The results of a search with the DELPHI Barrel RICH for anomalous Cherenkov rings having radii greater than those produced by ultrarelativistic particles were reported in our previous paper [1]. The search was based on the data collected by the DELPHI Collaboration at CERN during the LEP1 and LEP2 periods. A detailed study of background sources capable of producing apparently anomalous rings has been done; it indicated that the background hypothesis has a low probability ($10^{-3}$ or less). An additional strong argument against the background hypothesis was provided by the observation of a high degree of correlation between anomalous ring radii in the liquid and gaseous radiators in the selected events.The results obtained are interpreted in this paper in terms of observation of faster-than-light particles (tachyons). In the framework of this interpretation two peaks in the tachyon mass parameter distribution are observed, at $(0.29 \pm 0.01)$~GeV/c$^2$ and $(4.6 \pm 0.2)$~GeV/c$^2$. This work has been performed by the authors following the rules for external access to the DELPHI archived data, as established in http://delphiwww.cern.ch/delsec/finalrules/FINALrules011203.pdf The opinions, findings and conclusions expressed in this material are those of the authors alone and do not reflect in any way the views of the DELPHI Collaboration.
Motivation & Objective
- To investigate the physical origin of anomalous Cherenkov rings in the DELPHI Barrel RICH detector, which exhibit radii larger than those expected from ultrarelativistic particles.
- To rule out background sources as the cause of these rings, given their low probability (≤10⁻³) and lack of consistency across radiator types.
- To explore the hypothesis that the rings result from faster-than-light particles (tachyons), consistent with relativistic causality in a preferred rest frame.
- To determine the tachyon mass parameter distribution using kinematic fitting of ring radii and momentum measurements in both liquid and gaseous radiators.
- To validate the tachyon interpretation through correlation analysis between ring radii in the two radiator types, which shows strong consistency.
Proposed method
- Kinematic fitting of events with anomalous rings using constraint equations that enforce energy-momentum conservation and Cherenkov angle relations for tachyons.
- Application of the tachyon Cherenkov formula cosθc = 1/(nβ), where β > 1 for tachyons, to relate ring radius to tachyon velocity and refractive index.
- Use of two radiator types—liquid C₆F₁₄ (n=1.273) and gaseous C₅F₁₂ (n=1.00194)—to cross-validate ring radius measurements and reduce systematic bias.
- Implementation of three topologies (1a, 1b, 2) in the fitting procedure, each with distinct kinematic constraints involving tachyon momenta, energies, and ISR photon contributions.
- Incorporation of dE/dx measurements and Fermi plateau corrections to assess tachyon velocity and consistency with the tachyon hypothesis.
- Use of constraint equations (A1.1–A1.7, A2.1–A2.6, A3.1–A3.2) to solve for unknowns such as tachyon mass parameter μ, energy, and momentum, while enforcing momentum and energy conservation.
Experimental results
Research questions
- RQ1Can the anomalous Cherenkov rings, with radii exceeding those of ultrarelativistic particles, be explained by known background sources in the DELPHI detector?
- RQ2Is there a physical explanation for the observed correlation between ring radii in the liquid and gaseous radiators that would rule out random background fluctuations?
- RQ3Do the kinematic constraints of the events support the existence of faster-than-light particles (tachyons) with specific mass parameters?
- RQ4What are the inferred mass parameters of the tachyons responsible for the anomalous rings, as determined by consistent fitting across both radiator types?
- RQ5Is the tachyon interpretation consistent with relativistic causality and energy-momentum conservation in a preferred rest frame?
Key findings
- The background hypothesis for the anomalous rings has a probability of 10⁻³ or less, indicating a low likelihood of random or instrumental origin.
- A high degree of correlation between anomalous ring radii in the liquid and gaseous radiators strongly supports a genuine physical origin rather than background fluctuations.
- Two distinct peaks in the tachyon mass parameter distribution are observed at 0.29±0.01 GeV/c² and 4.6±0.2 GeV/c², suggesting two populations of tachyons.
- The kinematic fitting procedure successfully constrains tachyon momenta, energies, and mass parameters using Cherenkov ring radii and momentum measurements.
- The consistency of results across both radiator types and multiple event topologies strengthens the tachyon hypothesis over alternative explanations.
- The authors conclude that the observed data are most plausibly interpreted as evidence for tachyons, though they explicitly state these findings do not reflect the views of the DELPHI Collaboration.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.