Skip to main content
QUICK REVIEW

[Paper Review] Piezoelectric Drop-on-Demand Inkjet Printing of Rat Fibroblast Cells: Survivability Study and Pattern Printing

Er Qiang Li, Eng Khoon Tan|arXiv (Cornell University)|Oct 2, 2013
3D Printing in Biomedical ResearchEngineering45 references7 citations
TL;DR

This study develops a custom piezoelectric drop-on-demand inkjet system to print L929 rat fibroblast cells, investigating the impact of nozzle diameter and droplet velocity on cell survivability. Key findings show that shear stress during ejection reduces survival from 95% to 76% at 36 µm nozzle and 16 m/s velocity, while higher viability is maintained with larger nozzles, and printed cells successfully adhere and proliferate on collagen substrates over 5 days.

ABSTRACT

A novel piezoelectric, drop-on-demand (DOD) inkjet system has been developed and used to print L929 rat fibroblast cells. We investigate the survivability of the cells subjected to the large stresses during the printing process. These stresses are varied by changing the diameter of the orifice (36 to 119 microns) through which the cells are dispensed, as well as changing the electrical pulse used to drive the piezoelectric element. It is shown that for the smallest 36 microns diameter orifice, cell survival rates fall from 95% to approximately 76% when the ejection velocity is increased from 2 to 16 m/s. This decrease in survival rates is less significant when the larger orifice diameters of 81 microns and 119 microns are used. Analysis shows that there is a clear inverse relationship between cell survival rates and the mean shear rates during drop formation. By using the same printing set-up, fibroblast cells are printed onto alginate and collagen into patterns. Printed cells are cultured over a period of days to verify their long-term viability. Fibroblasts printed onto the collagen are found to successfully adhere, spread and proliferate, subsequently forming a denser patterns after 5 days in culture. Cell agglomeration is found to affect the printing performance, especially for the printhead with the smallest orifice, leading to frequent clogging of the nozzle. We also study the number of cells in each droplet, when printed under optimal conditions. The probability density of this number follows a binomial distribution, which consistent with a uniform distribution of cells in the medium and within the printhead.

Motivation & Objective

  • To develop a custom piezoelectric drop-on-demand inkjet system with variable orifice diameters to study cell survivability under controlled shear stresses.
  • To investigate the effects of droplet velocity and nozzle diameter on the viability of L929 rat fibroblast cells during inkjet printing.
  • To evaluate long-term cell viability, adhesion, and proliferation after printing onto alginate and collagen substrates.
  • To quantify the distribution of cells per droplet to optimize printing for consistent cell delivery and avoid cell-less droplets.
  • To identify critical parameters that influence cell survival and printing reliability, especially for small orifices prone to clogging.

Proposed method

  • A custom squeeze-mode piezoelectric printhead was designed to allow interchangeable glass nozzles with diameters of 36, 81, and 119 µm.
  • Droplet ejection was controlled via variable voltage pulses (52–140 V) from a JetDrive™ III controller, enabling precise tuning of droplet velocity (2–16 m/s).
  • Cell survival was assessed using a live/dead assay with calcein AM (green, live) and ethidium homodimer-1 (red, dead), with fluorescence microscopy for quantification.
  • Cells were printed onto 1.0% alginate films (100 µm thick) and 0.3% collagen gels (2 mm thick), with medium changes after 1 hour to prevent dehydration.
  • Shear rate during droplet formation was calculated from droplet velocity and orifice geometry, and correlated with survival rates.
  • The number of cells per droplet was modeled using a binomial distribution to assess uniformity and optimize cell concentration in the ink.

Experimental results

Research questions

  • RQ1How does nozzle diameter (36–119 µm) influence the survivability of L929 rat fibroblast cells during piezoelectric inkjet printing?
  • RQ2What is the relationship between droplet ejection velocity (2–16 m/s) and cell viability, particularly under high shear stress conditions?
  • RQ3How do shear stresses during droplet formation correlate with observed cell death rates?
  • RQ4Can printed L929 fibroblasts successfully adhere, spread, and proliferate on collagen and alginate substrates over 5 days in culture?
  • RQ5What is the probability distribution of the number of cells per droplet, and how does it relate to ink uniformity and cell concentration?

Key findings

  • At a 36 µm nozzle, cell survival decreased from 95% to approximately 76% when droplet velocity increased from 2 to 16 m/s, indicating significant shear stress-induced damage.
  • For larger nozzles (81 µm and 119 µm), the reduction in survival with increasing velocity was less pronounced, suggesting lower shear stress exposure.
  • A clear inverse relationship was observed between mean shear rate during droplet formation and cell survival rate, confirming shear stress as a primary factor in cell death.
  • Fibroblasts printed onto collagen substrates successfully adhered, spread, and proliferated, forming denser patterns after 5 days in culture.
  • Cell agglomeration caused frequent nozzle clogging, particularly in the 36 µm nozzle, reducing printing reliability.
  • The number of cells per droplet followed a binomial distribution, consistent with uniform cell distribution in the ink and within the printhead.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.