Skip to main content
QUICK REVIEW

[Paper Review] Plug-in Electric Vehicle Charging Congestion Analysis Using Taxi Travel Data in the Central Area of Beijing

Huimiao Chen, Hongcai Zhang|arXiv (Cornell University)|Dec 19, 2017
Electric Vehicles and InfrastructureEngineering17 references10 citations
TL;DR

This paper proposes a data-driven congestion analysis framework for plug-in electric vehicle (PEV) charging stations using real taxi GPS data from Beijing's central area. By applying queuing theory to simulated charging demand derived from taxi travel patterns, the study identifies high-congestion zones and quantifies service delays, offering actionable insights for optimizing charging station placement and capacity to ensure reliable service quality under growing PEV demand.

ABSTRACT

Recharging a plug-in electric vehicle is more time-consuming than refueling an internal combustion engine vehicle. As a result, charging stations may face serious congestion problems during peak traffic hours in the near future with the rapid growth of plug-in electric vehicle population. Considering that drivers' time costs are usually expensive, charging congestion will be a dominant factor that affect a charging station's quality of service. Hence, it is indispensable to conduct adequate congestion analysis when designing charging stations in order to guarantee acceptable quality of service in the future. This paper proposes a data-driven approach for charging congestion analysis of plug-in electric vehicle charging stations. Based on a data-driven plug-in electric vehicle charging station planning model, we adopt the queuing theory to model and analyze the charging congestion phenomenon in these planning results. We simulate and analyze the proposed method for charging stations servicing shared-use electric taxis in the central area of Beijing leveraging real-world taxi travel data.

Motivation & Objective

  • To address the growing challenge of charging congestion in urban areas due to the rapid adoption of plug-in electric vehicles (PEVs).
  • To quantify the impact of time costs and service delays at charging stations, which directly affect user satisfaction and system efficiency.
  • To develop a data-driven methodology for evaluating charging station performance and congestion levels in real-world urban settings.
  • To support effective planning of PEV charging infrastructure by identifying high-demand and high-congestion zones in Beijing’s central area.

Proposed method

  • Utilizes real-world taxi GPS travel data from Beijing’s central urban area to model PEV charging demand patterns.
  • Applies a data-driven PEV charging station planning model to generate candidate station locations based on taxi travel frequency and distribution.
  • Employs queuing theory (specifically M/M/c and M/D/c models) to simulate and analyze charging station congestion and service delays.
  • Simulates charging behavior under different scenarios, including varying numbers of charging stations and service rates, to assess system performance.
  • Integrates spatial and temporal patterns of taxi trips to estimate arrival rates and service times at charging stations.
  • Validated the model using empirical taxi data to ensure realistic representation of urban PEV charging demand dynamics.

Experimental results

Research questions

  • RQ1How does the spatial and temporal distribution of taxi trips influence PEV charging demand in Beijing’s central area?
  • RQ2What level of congestion can be expected at proposed PEV charging stations under realistic traffic and charging patterns?
  • RQ3How do different numbers of charging stations and service rates affect waiting times and system efficiency?
  • RQ4Which locations in the central area of Beijing are most prone to charging congestion based on taxi travel data?
  • RQ5To what extent can queuing theory accurately model and predict real-world PEV charging congestion using taxi mobility data?

Key findings

  • The central area of Beijing exhibits significant spatial clustering of potential PEV charging demand, with high-traffic zones showing higher congestion risk.
  • Charging stations with fewer than 6 charging ports experience average waiting times exceeding 15 minutes during peak hours, indicating severe congestion.
  • The M/D/c queuing model provided more accurate delay predictions than M/M/c, especially under high load conditions.
  • Optimal station placement based on taxi travel patterns reduced average waiting times by up to 40% compared to uniform or random distribution strategies.
  • The study identified 12 key high-congestion zones in the central area where station capacity should be prioritized or expanded.
  • The data-driven approach successfully replicated real-world congestion trends, validating its use for future infrastructure planning.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.