[Paper Review] Precise Numerical Evaluation of the Scalar One-Loop Integrals with the Infrared Divergence
This paper presents a novel numerical method for computing scalar one-loop integrals with infrared divergences, combining adaptive numerical integration, extrapolation in the regulator parameter $\epsilon$, and multi-precision arithmetic. It achieves agreement with analytic results to 10-digit precision even for photon masses as small as $10^{-150}$ GeV, demonstrating that precision control is essential for stable, reliable results in high-accuracy quantum field theory calculations.
We present a new approach for obtaining very precise integration results for infrared vertex and box diagrams, where the integration is carried out directly without performing any analytic integration of Feynman parameters. Using an appropriate numerical integration routine with an extrapolation method, together with a multi-precision library, we have obtained integration results which agree with the analytic results to 10 digits even for such a very small photon mass as $10^{-150}$ GeV in the infrared vertex diagram.
Motivation & Objective
- To develop a robust numerical method for scalar one-loop vertex and box diagrams with infrared singularities.
- To address the challenge of maintaining numerical precision when the fictitious photon mass $\lambda$ becomes extremely small, such as $10^{-150}$ GeV.
- To demonstrate that precision control is essential for stable and accurate results in high-accuracy quantum field theory computations.
- To validate the method by comparing numerical results with analytic solutions across a wide range of $\lambda$ values.
Proposed method
- The method uses a numerical integration routine (DQAGE) with adaptive quadrature to compute loop integrals directly without analytic parameter integration.
- It introduces a regulator $i\epsilon$ in the propagator denominator to avoid divergence, with $\epsilon$ treated as a finite positive parameter.
- A sequence of integrals $I(\epsilon_l)$ is computed for decreasing $\epsilon_l$ values, followed by extrapolation to $\epsilon \to 0$ to recover the physical limit.
- Multi-precision arithmetic (double, quadruple, up to 32-precision) is employed to control numerical errors, especially for very small $\lambda$.
- The method combines precision control with extrapolation to stabilize results and detect lost bits during computation.
- The approach is applied to both one-loop vertex and box diagrams, with parameters tuned per diagram and $\lambda$ value.
Experimental results
Research questions
- RQ1Can a fully numerical method achieve 10-digit agreement with analytic results for one-loop vertex and box diagrams with infrared singularities?
- RQ2How does the required numerical precision scale as the photon mass $\lambda$ decreases below $10^{-30}$ GeV?
- RQ3What is the role of precision control in stabilizing numerical results for infrared-divergent loop integrals?
- RQ4Can extrapolation in $\epsilon$ reliably recover the $\epsilon \to 0$ limit when standard double or quadruple precision fails?
- RQ5What computational cost is associated with maintaining high precision for extremely small $\lambda$ values?
Key findings
- For the one-loop vertex diagram with $\lambda = 10^{-150}$ GeV, the numerical result for the real part agrees with the analytic value to 11 digits of precision.
- At $\lambda = 10^{-150}$ GeV, the imaginary part of the vertex diagram is computed with 10-digit agreement using 32-precision arithmetic.
- For the one-loop box diagram with $\lambda = 10^{-25}$ GeV, the numerical result matches the analytic result to 7 digits, while at $\lambda = 10^{-30}$ GeV, agreement drops to 4 digits without sufficient precision control.
- The method achieves 10-digit agreement with analytic results even at $\lambda = 10^{-150}$ GeV, confirming the necessity of high-precision arithmetic for such extreme cases.
- The elapsed time for $\lambda = 10^{-150}$ GeV in the vertex diagram reaches 6.8 days on a Xeon 3.06 GHz processor, highlighting the computational cost of high-precision calculations.
- The study confirms that precision control is not optional but essential for reliable results in infrared-divergent loop integrals, especially when $\lambda < 10^{-30}$ GeV.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.