[Paper Review] Precision measurement of the (e$^+$ + e$^-$) flux in primary cosmic rays from 0.5 GeV to 1 TeV with the Alpha Magnetic Spectrometer on the International Space Station
This paper presents a high-precision measurement of the combined electron and positron flux in primary cosmic rays from 0.5 GeV to 1 TeV using the Alpha Magnetic Spectrometer (AMS-02) on the International Space Station. The flux is smooth and well described by a single power law with a spectral index of $\gamma = -3.170 \pm 0.008$ above 30.2 GeV, indicating no significant structures or deviations in the energy spectrum up to 1 TeV.
We present a precise measurement of the combined electron plus positron flux from 0.5 GeV to 1 TeV, based on the analysis of the data collected by the Alpha Magnetic Spectrometer during the first 30 months of operations aboard the International Space Station. The statistics and the high resolution of AMS-02 detector provide a precise measurement of the flux. The flux is smooth and reveals new and distinct information. Above 30.2 GeV, the combined electron plus positron flux can be described accurately by a single power law.
Motivation & Objective
- To measure the combined flux of primary cosmic ray electrons and positrons with high precision across a broad energy range.
- To determine whether the flux exhibits any spectral structures or deviations from a power-law behavior above 30 GeV.
- To improve the energy resolution and statistical accuracy of the flux measurement by leveraging the high statistics and low background of the AMS-02 detector.
- To validate the absolute energy scale and selection efficiency using flight data and test beam calibration.
- To provide a model-independent characterization of the energy dependence of the combined e⁺+e⁻ flux.
Proposed method
- The flux is measured using 41 × 10⁹ cosmic ray events collected over 30 months of AMS-02 operations on the ISS.
- The effective acceptance and exposure time are calculated using detector geometry, selection efficiency from simulations, and validated with pure electron data samples.
- Signal events are identified using a combination of tracker momentum, ECAL energy deposition, TRD transition radiation, and TOF timing to reject protons and background.
- A template fit procedure is applied in each energy bin to estimate signal and background counts, with bin widths set to at least twice the energy resolution.
- The spectral index is determined via a sliding energy window fit to $\Phi(e^+ + e^-) = C E^\gamma$, with uncertainties propagated from statistical, systematic, and energy scale sources.
- Energy scale calibration is verified using minimum ionizing particles and E/p matching, with 2% uncertainty between 10–290 GeV and 5% at 0.5 GeV and 1 TeV.
Experimental results
Research questions
- RQ1Does the combined electron and positron flux exhibit any spectral structures or deviations from a power-law behavior above 30 GeV?
- RQ2What is the precise energy dependence of the combined e⁺+e⁻ flux from 0.5 GeV to 1 TeV?
- RQ3How does the spectral index of the flux vary across the energy range, and is it consistent with a single power law?
- RQ4To what extent does the positron excess observed in previous measurements affect the combined flux behavior?
- RQ5What is the impact of energy scale uncertainty on the flux measurement and spectral index determination?
Key findings
- The combined (e⁺ + e⁻) flux from 0.5 GeV to 1 TeV is smooth and exhibits no significant spectral structures or features.
- Above 30.2 GeV, the flux is well described by a single power law with a spectral index of $\gamma = -3.170 \pm 0.008$ (stat+syst) \pm 0.008 (energy scale).
- The statistical uncertainty dominates above 140 GeV, with bin-to-bin migration errors below 1% and decreasing to 0.2% above 10 GeV.
- The energy scale uncertainty is 2% between 10 and 290 GeV, increasing to 5% at 0.5 GeV and 1 TeV, which is treated as a systematic uncertainty on bin boundaries.
- The measurement extends to 1 TeV with higher selection efficiency than individual electron or positron flux measurements due to charge-independent selection.
- The flux is rescaled by $E^3$ and shows no deviation from the power-law fit above 30.2 GeV, confirming a consistent energy dependence across the measured range.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.