Skip to main content
QUICK REVIEW

[Paper Review] Precision Measurement of the Excited State Landé g-factor and Diamagnetic Shift of the Cesium D$_{2}$ Line

Hans Stærkind, Kasper Jensen|arXiv (Cornell University)|Jul 29, 2022
Atomic and Subatomic Physics ResearchPhysics and Astronomy50 references4 citations
TL;DR

This study presents a precision measurement of the excited-state Landé g-factor and the diamagnetic shift for the cesium D2 line using saturated absorption spectroscopy in 3 T and 7 T magnetic fields. By probing extreme Zeeman states, the authors achieve a 1 ppm accuracy in optical magnetic field measurement, yielding gJ(62P3/2) = 1.33408749(52), an improvement of over two orders of magnitude, and report the first-ever measurement of the quadratic diamagnetic shift, γ2 = 0.4644(35) MHz/T².

ABSTRACT

We have performed saturated absorption spectroscopy on the cesium D$_{2}$ line in 3 T and 7 T magnetic fields. By means of sideband spectroscopy on the extreme angular momentum states we have measured the linear magnetic frequency shift of the transition to be $γ_1 = 13.994\:301(11)$ GHz/T. This corresponds to an optical magnetic field measurement of better than 1 ppm accuracy. From this value we can calculate the fine structure Landé g-factor $g_J\left(6^2P_{3/2} ight) = 1.334\:087\:49(52)$. This is consistent with the previous best measurement, and improves the accuracy by more than two orders of magnitude. We have also measured, for the first time ever, the quadratic diamagnetic shift as $γ_2 = 0.4644(35)\:\mathrm{MHz/T^2}$. Our work opens up the field of accurate high field optical magnetometry using atomic cesium. These high accuracy measurements also allow for testing of advanced atomic structure models, as our results are incompatible with the Russel-Saunders coupling value, and the hydrogen-constant-core-model value, by 31 and 7 standard deviations respectively.

Motivation & Objective

  • To improve the accuracy of the excited-state Landé g-factor for the cesium D2 line beyond previous measurements.
  • To measure the quadratic diamagnetic shift of the cesium D2 line for the first time.
  • To enable high-accuracy optical magnetometry in high magnetic fields using cesium atoms.
  • To test advanced atomic structure models by comparing experimental results with theoretical predictions.

Proposed method

  • Performed saturated absorption spectroscopy on the cesium D2 line in 3 T and 7 T magnetic fields using MRI scanners for stable, homogeneous fields.
  • Utilized sideband spectroscopy on extreme angular momentum states (|F, mF⟩ = |5, ±5⟩) to resolve linear Zeeman shifts.
  • Measured the linear magnetic frequency shift γ1 = 13.994301(11) GHz/T, corresponding to the optical magnetic field sensitivity.
  • Calculated the fine-structure Landé g-factor gJ(62P3/2) from the measured γ1 using the relation γ1 = gJ μB B / h.
  • Determined the quadratic diamagnetic shift γ2 = 0.4644(35) MHz/T² by fitting the observed transition frequency shift to a quadratic model.
  • Validated field calibration using NMR spectroscopy on protons in water, ensuring high-accuracy field determination.

Experimental results

Research questions

  • RQ1What is the precise value of the excited-state Landé g-factor for the cesium 62P3/2 state?
  • RQ2What is the magnitude of the quadratic diamagnetic shift for the cesium D2 line in high magnetic fields?
  • RQ3How does the measured g-factor compare to theoretical predictions based on Russell-Saunders coupling and the hydrogen-constant-core model?
  • RQ4Can the measured data be used to test advanced atomic structure models beyond standard coupling schemes?
  • RQ5To what extent does the high-accuracy measurement enable improved optical magnetometry in the tesla range?

Key findings

  • The excited-state Landé g-factor for the cesium D2 line was measured as gJ(62P3/2) = 1.33408749(52), improving the accuracy by over two orders of magnitude compared to previous measurements.
  • The linear magnetic frequency shift was measured as γ1 = 13.994301(11) GHz/T, enabling optical magnetic field measurements with better than 1 ppm accuracy.
  • The quadratic diamagnetic shift was measured for the first time as γ2 = 0.4644(35) MHz/T².
  • The measured g-factor deviates from the Russell-Saunders coupling value by 31 standard deviations and from the hydrogen-constant-core-model value by 7 standard deviations, indicating strong deviations from simple coupling models.
  • The results provide a benchmark for testing advanced atomic structure calculations and enable high-accuracy optical magnetometry in high magnetic fields.
  • The study demonstrates the feasibility of using cesium atoms for continuous, all-optical, high-field magnetometry without RF excitation.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.