Skip to main content
QUICK REVIEW

[Paper Review] Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector

Prabal Adhikari, Rahaf Ajaj|arXiv (Cornell University)|Feb 27, 2023
Dark Matter and Cosmic PhenomenaPhysics and Astronomy28 references4 citations
TL;DR

This paper presents the most precise measurement to date of the specific activity of $^{39}$Ar in atmospheric argon using the DEAP-3600 liquid argon detector. By analyzing single $^{39}$Ar decays and double-pileup events with a data-driven fit method, the study reports a specific activity of $0.964 \pm 0.001_{\text{stat}} \pm 0.024_{\text{sys}}$ Bq/kg$_{\text{atmAr}}$, significantly improving statistical precision and refining systematic uncertainties from cut efficiency, energy scale, and $^{85}$Kr contamination.

ABSTRACT

The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{ m atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.

Motivation & Objective

  • To measure the specific activity of $^{39}$Ar in atmospheric argon with unprecedented precision using the DEAP-3600 liquid argon detector.
  • To reduce systematic uncertainties in $^{39}$Ar activity measurements by improving cut efficiency estimates, energy scale calibration, and livetime calculation.
  • To provide a critical input for background modeling in noble liquid-based dark matter experiments.
  • To support radiometric dating applications that rely on the $^{39}$Ar/Ar ratio as a chronometric tool.
  • To validate and update previous measurements using new data, updated argon mass, and improved analysis techniques.

Proposed method

  • A data-driven fitting procedure was applied to single $^{39}$Ar events and double-pileup events surviving selection cuts, using measured and Monte Carlo-generated spectra as inputs.
  • Normalization parameters for the ERB and double-pileup spectra were floated in Bayesian fits with Gaussian priors centered on 1, corresponding to expected event rates and known live time.
  • The fit results were cross-validated using alternative spectra, including the Kostensalo et al. spectrum, showing negligible differences in the final activity value.
  • Systematic uncertainties were evaluated by varying key parameters: cut efficiency, energy scale, energy resolution, and potential $^{85}$Kr contamination in the argon.
  • The analysis incorporated updated LAr mass, revised livetime, and correction for the age of the atmospheric argon at extraction.
  • The final specific activity was derived from posterior distributions of the normalization parameters in the fit.

Experimental results

Research questions

  • RQ1What is the most precise measurement of the specific activity of $^{39}$Ar in atmospheric argon using the DEAP-3600 detector?
  • RQ2How do updated cut efficiency estimates and livetime calculations affect the uncertainty budget of the $^{39}$Ar activity measurement?
  • RQ3To what extent do systematic uncertainties from energy scale, resolution, and $^{85}$Kr contamination limit the precision of the measurement?
  • RQ4How does the new measurement compare with previous results from WARP, ArDM, and earlier DEAP-3600 analyses?
  • RQ5Can the data-driven fitting method reliably extract $^{39}$Ar activity from a low-background, high-statistics dataset?

Key findings

  • The specific activity of $^{39}$Ar in atmospheric argon is measured as $0.964 \pm 0.001_{\text{stat}} \pm 0.024_{\text{sys}}$ Bq/kg$_{\text{atmAr}}$, representing the most precise determination to date.
  • Statistical uncertainties are dominated by the high statistics of the dataset, while systematic uncertainties are primarily driven by event selection cut efficiency, energy scale, and energy resolution.
  • The inclusion of $^{85}$Kr in the argon target contributes a small but measurable systematic effect, which was carefully evaluated and corrected for.
  • The result is consistent with previous measurements from WARP and ArDM, and shows no significant deviation from earlier DEAP-3600 estimates after updates.
  • The data-driven fit method yields results that are robust and consistent across different input spectra, including the Kostensalo et al. spectrum.
  • The updated analysis incorporates a corrected argon age and improved mass and livetime estimates, enhancing the reliability of the final value.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.