[Paper Review] Proposal to generate 10 TW level femtosecond x-ray pulses from a baseline undulator in conventional SASE regime at the European XFEL
This paper proposes generating 10 TW-level, 3 fs-long x-ray pulses at the European XFEL by leveraging ultra-high peak current (45 kA) in the baseline SASE3 undulator without hardware modifications. By compressing a 0.25 nC electron bunch and applying undulator tapering, the authors demonstrate a 100-fold increase in peak power, achieving up to 5 TW in the SASE regime, with a 1% radiation bandwidth suitable for single biomolecule imaging at 3–5 keV photon energies.
Output characteristics of the European XFEL have been previously studied assuming an operation point at 5 kA peak current. In this paper we explore the possibility to go well beyond such nominal peak current level. In order to illustrate the potential of the European XFEL accelerator complex we consider a bunch with 0.25 nC charge, compressed up to a peak current of 45 kA. An advantage of operating at such high peak current is the increase of the x-ray output peak power without any modification to the baseline design. Based on start-to-end simulations, we demonstrate that such high peak current, combined with undulator tapering, allows one to achieve up to a 100-fold increase in a peak power in the conventional SASE regime, compared to the nominal mode of operation. In particular, we find that 10 TW-power level, femtosecond x-ray pulses can be generated in the photon energy range between 3 keV and 5 keV, which is optimal for single biomolecule imaging. Our simulations are based on the exploitation of all the 21 cells foreseen for the SASE3 undulator beamline, and indicate that one can achieve diffraction to the desired resolution with 15 mJ (corresponding to about 3e13 photons) in pulses of about 3 fs, in the case of a 100 nm focus at the photon energy of 3.5 keV.
Motivation & Objective
- To explore the potential of the European XFEL accelerator complex to exceed nominal operation parameters, particularly peak current, without hardware modifications.
- To address the challenge of achieving sufficient x-ray peak power (10 TW) for single biomolecule imaging using the 'diffraction before destruction' method.
- To determine if high-peak-current operation combined with undulator tapering can significantly enhance SASE output power in the conventional SASE regime.
- To assess the feasibility of generating femtosecond x-ray pulses with sufficient photon fluence and appropriate bandwidth for structural biology applications.
- To evaluate whether the resulting 1% radiation bandwidth is acceptable for applications like biomolecular imaging where high spectral purity is not required.
Proposed method
- Utilized start-to-end simulations to model electron beam dynamics from the linac through the SASE3 undulator, including space charge, RF wakefields, and coherent synchrotron radiation effects.
- Optimized beam parameters for a 0.25 nC electron bunch compressed to 45 kA peak current, achieving a normalized slice emittance of ~4 μm.
- Applied undulator tapering via discrete gap adjustments across 12 of the 21 undulator cells to maintain resonance as electron energy decreases during FEL interaction.
- Employed a two-part undulator configuration: 9 cells of uniform field for SASE saturation (reaching ~0.5 TW), followed by 12 tapered cells to boost output to ~5 TW.
- Used statistical averaging over 100 single-shot realizations to assess stability and characterize output power, spectrum, and energy fluctuations.
- Evaluated radiation pulse energy distribution and angular spread to assess focusability and experimental usability.
Experimental results
Research questions
- RQ1Can the European XFEL generate 10 TW-level x-ray pulses in the conventional SASE regime without additional hardware beyond the baseline design?
- RQ2To what extent can undulator tapering enhance SASE output power when combined with ultra-high peak current electron bunches?
- RQ3What is the impact of large energy chirp (due to high peak current) on radiation bandwidth and whether it remains acceptable for biomolecular imaging?
- RQ4Can the SASE saturation length remain within practical limits when operating at 45 kA peak current with increased slice emittance and energy spread?
- RQ5Is the resulting 1% radiation bandwidth sufficient for high-contrast single biomolecule diffraction imaging without monochromatization?
Key findings
- A 100-fold increase in peak power is achievable in the conventional SASE regime by increasing the electron bunch peak current to 45 kA, reaching up to 5 TW output power.
- The SASE3 undulator can achieve SASE saturation at ~0.5 TW in the first 9 undulator cells due to the high peak current, even with a slice emittance of ~4 μm.
- Undulator tapering over the final 12 cells increases the output power from 0.5 TW to approximately 5 TW, demonstrating a significant enhancement without hardware upgrades.
- The radiation bandwidth reaches about 1% due to large energy chirp in the electron bunch, which is acceptable for applications like single biomolecule imaging where photon fluence is more critical than spectral purity.
- The system can produce 15 mJ of pulse energy (equivalent to ~3×10¹³ photons) in a 3 fs pulse at 3.5 keV photon energy, suitable for achieving atomic resolution with a 100 nm focus.
- The proposed method maintains SASE saturation within a safe range of 9 undulator cells, confirming the feasibility of high-peak-current operation despite increased longitudinal velocity spread and emittance.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.