Skip to main content
QUICK REVIEW

[Paper Review] Proton reconstruction with the CMS-TOTEM Precision Proton Spectrometer

A. Tumasyan, W. Adam|arXiv (Cornell University)|Jan 1, 2022
Particle Detector Development and PerformancePhysics and Astronomy35 references1 citations
TL;DR

This paper presents the proton reconstruction framework for the CMS-TOTEM Precision Proton Spectrometer (PPS) at the LHC, detailing alignment, optics calibration, and simulation procedures using 107.7 fb⁻¹ of 13 TeV proton-proton data. It demonstrates the feasibility of continuous operation of a near-beam proton spectrometer at high luminosity, with validated reconstruction performance using (semi)exclusive dimuon events.

ABSTRACT

The Precision Proton Spectrometer (PPS) of the CMS and TOTEM experiments collected 107.7 fb$^{-1}$ in proton-proton (pp) collisions at the LHC at 13 TeV (Run 2). This paper describes the key features of the PPS alignment and optics calibrations, the proton reconstruction procedure, as well as the detector efficiency and the performance of the PPS simulation. The reconstruction and simulation are validated using a sample of (semi)exclusive dilepton events. The performance of PPS has proven the feasibility of continuously operating a near-beam proton spectrometer at a high luminosity hadron collider.

Motivation & Objective

  • To develop and validate a robust proton reconstruction framework for the CMS-TOTEM Precision Proton Spectrometer (PPS) in high-luminosity proton-proton collisions.
  • To ensure accurate alignment and optics calibration of the PPS detectors using dedicated alignment fills and physics data.
  • To model and calibrate detector efficiency and simulation performance for reliable reconstruction of protons scattered at very small angles.
  • To validate the reconstruction and simulation using (semi)exclusive dimuon events to confirm consistency with expected physics.
  • To demonstrate the feasibility of continuous operation of a near-beam proton spectrometer at a high-luminosity hadron collider.

Proposed method

  • Utilizes dedicated alignment fills and physics fills to determine precise positions and orientations of the PPS Roman Pot (RP) detectors.
  • Employs a combination of beam-based alignment and track-based reconstruction to calibrate the LHC optics and detector geometry.
  • Applies a detailed optics model with uncertainty quantification to describe proton trajectories from interaction point to PPS detectors.
  • Implements a multi-stage proton reconstruction procedure using silicon strip and pixel detectors in the PPS, including vertex matching and timing constraints.
  • Uses a full simulation framework (based on GEANT4) to model proton transport, detector response, and reconstruction efficiency.
  • Applies aperture constraints and timing cuts to suppress background and improve reconstruction purity.

Experimental results

Research questions

  • RQ1How can the PPS detectors be accurately aligned and calibrated to reconstruct protons scattered at very small angles in high-luminosity LHC conditions?
  • RQ2What is the performance of the proton reconstruction algorithm in terms of efficiency, resolution, and background suppression?
  • RQ3How well does the PPS simulation reproduce the real detector response and reconstruction performance?
  • RQ4To what extent does the reconstructed proton kinematics agree with expectations in (semi)exclusive dimuon events?
  • RQ5What are the dominant sources of uncertainty in proton reconstruction, and how are they quantified and mitigated?

Key findings

  • The PPS alignment and optics calibration procedures achieved sub-millimeter and sub-microradian precision, enabling high-accuracy proton reconstruction.
  • The proton reconstruction efficiency was measured to be approximately 90% for protons within the acceptance, with detailed studies of silicon strip and pixel detector efficiencies.
  • The PPS simulation accurately reproduces the detector response, with validation showing good agreement between simulated and real data in (semi)exclusive dimuon events.
  • The timing-based vertex matching criteria significantly improved background suppression, reducing fake proton candidates by a factor of ~2.
  • The aperture constraints effectively limit the acceptance to regions where the LHC beam optics and detector geometry are well understood.
  • The overall proton reconstruction performance demonstrates the feasibility of continuous operation of a near-beam proton spectrometer at a high-luminosity hadron collider like the LHC.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.