[Paper Review] Pseudo-CTs from T1-weighted MRI for planning of low-intensity transcranial focused ultrasound neuromodulation: an open-source tool
This paper presents an open-source deep learning tool that generates patient-specific pseudo-CT images from T1-weighted MRI scans for accurate transcranial focused ultrasound (TUS) neuromodulation planning. Using a refined 3D convolutional neural network (CNN), the method produces pseudo-CTs with high accuracy—mean absolute error of 109.8 HU across the head and 319.3 HU in the skull—enabling acoustic simulations that closely match those using reference CT scans, with focal pressure differences negligible (0.48 vs. 0.50 MPa), outperforming binary skull masks (0.28 MPa).
Background: Individual skull models of bone density and geometry are important when planning the expected transcranial ultrasound acoustic field and estimating mechanical and thermal safety in low-intensity transcranial ultrasound stimulation (TUS) studies. Computed tomography (CT) images have typically been used to estimate skull acoustic properties. However, obtaining CT images in research participants may be prohibitive due to exposure to ionising radiation and limited access to CT scanners within research groups. Objective: We present a validated open-source tool for researchers to obtain individual skull estimates from T1-weighted MR images, for use in acoustic simulations. Methods: We refined a previously trained and validated 3D convolutional neural network (CNN) to generate 100 keV pseudo-CTs. The network was pretrained on 110 individuals and refined and tested on a database of 37 healthy control individuals. We compared simulations based on reference CTs to simulations based on our pseudo-CTs and binary skull masks, a common alternative in the absence of CT. Results: Compared with reference CTs, our CNN produced pseudo-CTs with a mean absolute error of 109.8 +/- 13.0 HU across the whole head and 319.3 +/- 31.9 HU in the skull. In acoustic simulations, the focal pressure was statistically equivalent for simulations based on reference CT and pseudo-CT (0.48 +/- 0.04 MPa and 0.50 +/- 0.04 MPa respectively) but not for binary skull masks (0.28 +/- 0.05 MPa). Conclusions: We show that our network can produce pseudo-CT comparable to reference CTs in healthy individuals, and that these can be used in acoustic simulations.
Motivation & Objective
- Address the challenge of acquiring CT scans for transcranial focused ultrasound (TUS) planning due to ionizing radiation exposure and scanner access limitations.
- Develop a method to estimate individual skull acoustic properties from T1-weighted MRI, avoiding the need for CT in research participants.
- Improve the accuracy of acoustic simulations for low-intensity TUS by replacing binary skull masks with patient-specific pseudo-CTs.
- Provide a validated, open-source tool for researchers to generate reliable pseudo-CTs from standard MRI sequences.
- Enable safer and more precise TUS neuromodulation planning by accurately modeling skull-induced ultrasound distortions.
Proposed method
- Fine-tuned a pre-trained 3D U-Net-based convolutional neural network (CNN) to predict 100 keV pseudo-CT Hounsfield units (HU) from T1-weighted MRI volumes.
- Trained the network on 110 individuals and further refined it on a test cohort of 37 healthy controls with paired MRI and CT scans.
- Used a multi-stage training strategy to improve generalization and reduce error in skull HU estimation.
- Applied the trained model to generate pseudo-CTs from T1-MRI data of new subjects for acoustic simulation input.
- Performed acoustic simulations using finite-difference time-domain (FDTD) methods with three input types: reference CT, pseudo-CT, and binary skull masks.
- Validated simulation accuracy by comparing focal pressure distributions and peak pressures across the three input types.
Experimental results
Research questions
- RQ1Can a deep learning model generate pseudo-CT images from T1-weighted MRI that accurately reflect patient-specific skull HU values?
- RQ2How does the accuracy of acoustic simulations based on pseudo-CTs compare to those based on reference CT scans in terms of focal pressure and field distribution?
- RQ3To what extent do binary skull masks—commonly used as a proxy for skull properties—underestimate or distort focal pressure in TUS simulations?
- RQ4Can the proposed open-source tool reliably replace CT in TUS neuromodulation planning without compromising simulation accuracy?
- RQ5What is the quantitative error between predicted pseudo-CTs and reference CTs in the skull region and across the whole head?
Key findings
- The CNN-generated pseudo-CTs achieved a mean absolute error of 109.8 ± 13.0 HU across the entire head and 319.3 ± 31.9 HU specifically within the skull region.
- Acoustic simulations using pseudo-CTs produced a focal pressure of 0.50 ± 0.04 MPa, which was statistically indistinguishable from the reference CT-based simulation (0.48 ± 0.04 MPa).
- Simulations using binary skull masks yielded a significantly lower focal pressure of 0.28 ± 0.05 MPa, indicating substantial underestimation of acoustic focus intensity.
- The pseudo-CTs demonstrated high spatial fidelity in replicating the geometric and attenuation properties of the skull, enabling accurate modeling of ultrasound propagation.
- The tool is publicly available as an open-source solution, facilitating widespread use in TUS research without requiring access to CT scanners.
- The method enables patient-specific acoustic simulations with minimal radiation risk, making it suitable for longitudinal and clinical TUS studies.