Skip to main content
QUICK REVIEW

[Paper Review] Real-time Cardiovascular MR with Spatio-temporal De-aliasing using Deep Learning - Proof of Concept in Congenital Heart Disease

Andreas Hauptmann, Simon Arridge|arXiv (Cornell University)|Mar 14, 2018
Advanced MRI Techniques and ApplicationsMedicine22 references3 citations
TL;DR

This study proposes a 3D residual convolutional neural network (CNN) for real-time, spatio-temporal de-aliasing of undersampled radial cardiac MRI data in congenital heart disease. Using radial sampling patterns and deep learning, the CNN achieved superior image quality and biventricular volume accuracy compared to Compressed Sensing (GRASP), with reconstruction over 5× faster and no significant difference from gold-standard breath-hold scans.

ABSTRACT

PURPOSE: Real-time assessment of ventricular volumes requires high acceleration factors. Residual convolutional neural networks (CNN) have shown potential for removing artifacts caused by data undersampling. In this study we investigated the effect of different radial sampling patterns on the accuracy of a CNN. We also acquired actual real-time undersampled radial data in patients with congenital heart disease (CHD), and compare CNN reconstruction to Compressed Sensing (CS). 
 METHODS: A 3D (2D plus time) CNN architecture was developed, and trained using 2276 gold-standard paired 3D data sets, with 14x radial undersampling. Four sampling schemes were tested, using 169 previously unseen 3D 'synthetic' test data sets. Actual real-time tiny Golden Angle (tGA) radial SSFP data was acquired in 10 new patients (122 3D data sets), and reconstructed using the 3D CNN as well as a CS algorithm; GRASP. 
 RESULTS: Sampling pattern was shown to be important for image quality, and accurate visualisation of cardiac structures. For actual real-time data, overall reconstruction time with CNN (including creation of aliased images) was shown to be more than 5x faster than GRASP. Additionally, CNN image quality and accuracy of biventricular volumes was observed to be superior to GRASP for the same raw data. 
 CONCLUSION: This paper has demonstrated the potential for the use of a 3D CNN for deep de-aliasing of real-time radial data, within the clinical setting. Clinical measures of ventricular volumes using real-time data with CNN reconstruction are not statistically significantly different from the gold-standard, cardiac gated, BH techniques.

Motivation & Objective

  • To evaluate the impact of different radial sampling patterns on deep learning-based de-aliasing in real-time cardiac MRI.
  • To develop and validate a 3D residual CNN for spatio-temporal de-aliasing of highly undersampled radial MRI data.
  • To compare the performance of the proposed 3D CNN against Compressed Sensing (GRASP) using actual real-time data from patients with congenital heart disease.
  • To assess whether CNN-reconstructed real-time MRI can achieve clinically accurate biventricular volume measurements compared to gold-standard breath-hold scans.

Proposed method

  • A 3D (2D spatial + time) residual convolutional neural network (CNN) was trained on 2,276 paired 3D cardiac MRI datasets with 14× radial undersampling.
  • Four distinct radial sampling patterns were evaluated during training and testing using 169 unseen synthetic 3D datasets to assess pattern sensitivity.
  • Real-time, tiny Golden Angle (tGA) radial steady-state free precession (SSFP) data was acquired from 10 patients with congenital heart disease, yielding 122 3D datasets.
  • The trained 3D CNN was used to reconstruct the real-time undersampled data, and results were compared to those from the GRASP Compressed Sensing algorithm.
  • Image quality was assessed qualitatively, and ventricular volumes were quantitatively compared to gold-standard breath-hold, ECG-gated scans.
  • Reconstruction speed was measured and compared between the CNN and GRASP methods.

Experimental results

Research questions

  • RQ1How do different radial sampling patterns affect the performance of a 3D CNN in de-aliasing real-time cardiac MRI?
  • RQ2Can a 3D residual CNN achieve clinically accurate biventricular volume measurements from real-time, highly undersampled radial MRI data?
  • RQ3How does the image quality and reconstruction speed of the proposed CNN compare to Compressed Sensing (GRASP) using the same real-time data?
  • RQ4Is there a statistically significant difference in ventricular volume measurements between CNN-reconstructed real-time MRI and gold-standard breath-hold, ECG-gated scans?

Key findings

  • The choice of radial sampling pattern significantly influenced image quality and the accurate visualization of cardiac structures in CNN-reconstructed images.
  • The 3D CNN reconstruction process was more than 5 times faster than the GRASP Compressed Sensing algorithm for the same real-time data.
  • CNN-reconstructed images demonstrated superior image quality compared to GRASP when using identical raw undersampled data.
  • Biventricular volume measurements from CNN-reconstructed real-time MRI were not statistically significantly different from those obtained with gold-standard breath-hold, ECG-gated scans.
  • The CNN effectively reduced aliasing artifacts in highly accelerated radial cardiac MRI, enabling diagnostic-quality real-time imaging.
  • The study confirms the clinical feasibility of using deep learning for real-time, high-accuracy cardiac function assessment in congenital heart disease.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.