[Paper Review] Recovery Time Measurements of Silicon Photomultipliers Using a Pulsed Laser
This study measures the pixel recovery time of Hamamatsu Multi-Pixel Photon Counters (MPPCs) using a pulsed laser and waveform analysis to assess their rate capability and double-hit resolution. By varying the time delay between two laser pulses (2–100 ns), the authors extract recovery time constants and find that 25×25 μm² MPPCs achieve 50 MHz maximum rate capability and 2 ns double-hit resolution at moderate over-voltages, with recovery degrading significantly at higher biases due to cross-talk and after-pulsing.
We performed an experimental study to determine the pixel recovery time of various Multi Pixel Photon Counters (MPPCs) in order to characterize their rate capability and double-hit resolution. The recovery time constant and its dependence on the operating voltage has been evaluated by measuring the photosensor response to two consecutive laser pulses with varying relative time differences of a few ns (2-3 ns) up to some 100 ns using a waveform analysis technique. A Monte Carlo simulation tool is being developed to model the MPPC recovery process and interpret experimental data. In this context, the influence of after-pulsing, cross-talk and dark-noise on the recovery process can be studied.
Motivation & Objective
- To experimentally determine the pixel recovery time of various MPPC sensors to evaluate their performance in high-rate environments.
- To assess the double-hit resolution and maximum count rate capability of MPPCs for use in high-energy physics experiments.
- To investigate the dependence of recovery time on operating voltage, particularly the impact of increased over-voltage on recovery degradation due to cross-talk and after-pulsing.
- To develop a Monte Carlo simulation tool to model MPPC recovery dynamics and interpret experimental data.
Proposed method
- A pulsed laser (404 nm, 32 ps FWHM) delivers two consecutive light pulses with variable time delays (2–100 ns) to illuminate the entire MPPC surface.
- Waveform digitization captures the sensor response to both pulses, enabling extraction of recovery curves from the amplitude decay of the second pulse.
- Recovery time constants are derived by fitting the measured recovery curves at low over-voltage (to minimize non-linear effects), with time constants extracted for 50%, 80%, and 95% recovery.
- The method directly measures recovery under realistic two-pulse conditions, contrasting with prior methods relying on after-pulse analysis limited to >10 ns delays.
- Monte Carlo simulations are developed to model recovery, incorporating parameters such as after-pulse probability (PAP), cross-talk probability (PCT), and dark-count rate (DCR).
- Simulation parameters are fitted to experimental data to validate the model and study the influence of individual noise processes on recovery dynamics.
Experimental results
Research questions
- RQ1What is the true recovery time constant of MPPC pixels under realistic two-pulse illumination, and how does it vary with pixel size and operating voltage?
- RQ2How does increasing over-voltage affect the recovery time, and what role do after-pulsing, cross-talk, and dark noise play in this degradation?
- RQ3To what extent can MPPCs resolve two closely spaced photons, and what is the minimum time resolution achievable?
- RQ4Can a Monte Carlo simulation accurately reproduce experimental recovery curves and isolate the contributions of different noise mechanisms?
- RQ5How do the measured recovery times compare to manufacturer specifications, and what are the implications for high-rate applications?
Key findings
- The 25×25 μm² MPPC (S10362-11-025U) achieves a 50% recovery time of 2.5 ns and 95% recovery in 11 ns at 1 V over-voltage, indicating a maximum rate capability of approximately 50 MHz.
- The 50×50 μm² MPPC (S10362-11-050U) reaches 50% recovery in 8 ns and 95% recovery in 33 ns at 1 V over-voltage, corresponding to a maximum rate capability of about 20 MHz.
- The 100×100 μm² MPPC (S10362-11-100U) shows 50% recovery in 30 ns and 95% recovery in 140 ns at 1 V over-voltage, with a maximum rate capability of around 5 MHz.
- At higher over-voltages (e.g., 4.3 V for the 025U), full recovery (95%) takes up to 130 ns, indicating a substantial degradation in performance due to increased cross-talk and after-pulsing.
- Double-hit resolution is experimentally demonstrated down to 2 ns for the 025U device and 3.5 ns for the 050U device, corresponding to ~30% recovery at the time of the second pulse.
- The Monte Carlo simulation shows good agreement with experimental data and suggests that the recovery time constant is nearly independent of over-voltage, consistent with findings in Ref. [6].
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.