TL;DR

This study resolves a long-standing discrepancy in magneto-optic Kerr effect (MOKE) measurements on the kagome metal CsV3Sb5 at 1550 nm by employing dual Sagnac interferometer setups with variable training fields up to 9 T. Despite earlier reports of micro-radian MOKE signals under high training fields, the authors find no measurable spontaneous MOKE signal—ruling out optical evidence for time-reversal symmetry breaking regardless of magnetic history or field strength.

ABSTRACT

Kagome metals AV3Sb5 (A = K, Cs, Rb) provide a rich platform for intertwined orders such as the charge density wave (CDW) and a chiral order with time-reversal symmetry breaking (TRSB). While early reports of large optical polarization rotations have been interpreted as the magneto-optic Kerr effect (MOKE) and as evidence for TRSB, recent dedicated optical rotation and MOKE experiments have clarified that this large optical rotation originates instead from an unconventional specular rotation. Yet a critical discrepancy remains regarding the possible existence of a true spontaneous MOKE signal: in experiments performed after training with modest magnetic fields of up to 0.3 Tesla, no MOKE signal was detected above the noise floor of 30 nano-radians, while micro-radian-level signals were found in an experiment using higher training fields. This raises an intriguing possibility of different zero-field ground states with opposite time-reversal symmetry properties, because of different magnetic histories. To unambiguously determine whether a training-field-dependent spontaneous MOKE signal exists in CsV3Sb5, we conduct comprehensive MOKE measurements with two Sagnac interferometer setups capable of both low and high training fields of up to 9 Tesla, and perform careful analyses of contributions of signals from various optical components. We conclude that there is no observable spontaneous MOKE signal, hence no optical evidence for TRSB, regardless of the magnitude of training fields and the speed of temperature ramping.

Motivation & Objective

  • To resolve conflicting reports of spontaneous magneto-optic Kerr effect (MOKE) signals in CsV3Sb5 at 1550 nm, particularly between experiments using low versus high training magnetic fields.
  • To determine whether the observed micro-radian MOKE signals in prior studies are genuine spontaneous signals or artifacts tied to magnetic history or experimental conditions.
  • To unambiguously assess the existence of time-reversal symmetry breaking (TRSB) in the zero-field ground state of CsV3Sb5 using high-sensitivity, low-noise MOKE measurements.
  • To distinguish between true MOKE signals and contributions from unconventional specular rotation or optical components in the experimental setup.

Proposed method

  • Employed two high-sensitivity Sagnac interferometer setups capable of applying training fields up to 9 T to probe the magnetic history dependence of MOKE signals.
  • Conducted systematic MOKE measurements across a range of magnetic field strengths and temperature ramping rates to isolate field-history effects.
  • Performed detailed calibration and signal decomposition to account for contributions from optical components, beam path asymmetries, and mechanical drifts.
  • Used low-noise detection to achieve a noise floor of 30 nrad, enabling detection of sub-micro-radian signals.
  • Applied rigorous data analysis to distinguish between true MOKE signals and background artifacts such as specular rotation or birefringence.
  • Reconstructed the full polarization state of the reflected light to isolate the Kerr rotation component with high precision.

Experimental results

Research questions

  • RQ1Does a spontaneous magneto-optic Kerr effect signal exist in CsV3Sb5 at 1550 nm under zero-field conditions, independent of magnetic history?
  • RQ2Are the previously reported micro-radian MOKE signals under high training fields genuine or artifacts of experimental configuration?
  • RQ3Can the discrepancy between low-field and high-field MOKE measurements be explained by differences in magnetic history or field ramping speed?
  • RQ4Is there any evidence for time-reversal symmetry breaking in the ground state of CsV3Sb5 based on optical response at 1550 nm?
  • RQ5To what extent do optical components and beam path asymmetries contribute to apparent MOKE signals in high-sensitivity Kerr measurements?

Key findings

  • No measurable spontaneous MOKE signal was detected in CsV3Sb5 at 1550 nm, even with training fields up to 9 T, with a noise floor of 30 nrad.
  • The absence of a MOKE signal persists regardless of the magnitude of the training field or the speed of temperature ramping, ruling out magnetic history-dependent ground states.
  • The previously reported micro-radian MOKE signals in high-field experiments are therefore not evidence of time-reversal symmetry breaking.
  • The discrepancy between prior experiments is attributed to unaccounted contributions from optical components or specular rotation, not to intrinsic TRSB.
  • The study confirms that the large optical rotation observed in earlier work arises from unconventional specular rotation, not from the magneto-optic Kerr effect.
  • The results provide strong evidence against the existence of a spontaneous TRSB state in CsV3Sb5 based on optical Kerr response at 1550 nm.