[Paper Review] Results of a direct search using synchrotron radiation for the low-energy $^{229}$Th nuclear isomeric transition
This study reports the first direct search for the $^{229}$Th nuclear isomeric transition using tunable vacuum-ultraviolet synchrotron radiation on $^{229}$Th-doped LiSrAlF₆ crystals. No evidence was found for the transition between 7.3 eV and 8.8 eV with lifetimes between 1–2 s and 2000–5600 s, excluding roughly half of the favored search region at 90% confidence level.
We report the results of a direct search for the (229)Th (I(π)=3/2(+)←5/2(+)) nuclear isomeric transition, performed by exposing (229)Th-doped LiSrAlF(6) crystals to tunable vacuum-ultraviolet synchrotron radiation and observing any resulting fluorescence. We also use existing nuclear physics data to establish a range of possible transition strengths for the isomeric transition. We find no evidence for the thorium nuclear transition between 7.3 eV and 8.8 eV with transition lifetime (1-2) s≲τ≲(2000-5600) s. This measurement excludes roughly half of the favored transition search area and can be used to direct future searches.
Motivation & Objective
- To directly probe the low-energy $^{229}$Th nuclear isomeric transition using external excitation, avoiding ambiguities from indirect decay-based measurements.
- To establish a precise exclusion region for the transition energy and lifetime by applying tunable vacuum-ultraviolet (VUV) radiation to $^{229}$Th-doped crystals.
- To constrain the transition strength and lifetime using existing nuclear physics data and theoretical models.
- To improve the sensitivity of future searches by identifying systematic effects and defining the limits of experimental detection.
Proposed method
- Irradiated $^{229}$Th-doped LiSrAlF₆ crystals with tunable vacuum-ultraviolet synchrotron radiation from the Advanced Light Source (ALS) across the 7.3–8.8 eV range.
- Monitored fluorescence emission from the crystal to detect any nuclear transition-induced luminescence.
- Used a high-transmission, VUV-transparent crystal mount to maximize detection efficiency and minimize background.
- Applied a statistical analysis based on Feldman and Cousins (1998) to determine exclusion limits at the 90% confidence level.
- Calibrated the experimental sensitivity using background data collected without VUV illumination.
- Constructed a 'favored region' for the transition lifetime using recent measurements of a related M1 transition in the thorium nucleus, with uncertainty bounds at two standard deviations.
Experimental results
Research questions
- RQ1Does the $^{229}$Th nuclear isomeric transition emit detectable fluorescence when excited by tunable VUV synchrotron radiation in a doped crystal?
- RQ2What is the upper limit on the transition strength for the $^{229}$Th isomeric transition in the energy range 7.3–8.8 eV?
- RQ3Can the experimental sensitivity and systematic errors be quantified to define reliable exclusion limits at the 90% confidence level?
- RQ4How do theoretical estimates of the transition lifetime compare with the observed exclusion region, and which model provides the most reliable prediction?
- RQ5What is the impact of potential systematic effects—such as beamline instability or non-radiative decay—on the exclusion limits?
Key findings
- No evidence was found for the $^{229}$Th nuclear isomeric transition between 7.3 eV and 8.8 eV, with vacuum lifetimes in the range of (1–2) s to (2000–5600) s.
- The experiment excludes approximately half of the previously favored region for the transition energy and lifetime at the 90% confidence level.
- The exclusion limit is nearly at the level of the experimental sensitivity, indicating minimal excess noise and high detection reliability.
- The systematic error budget was estimated to potentially reduce the exclusion limit by up to a factor of two, but the primary exclusion remains robust.
- The favored region for the transition lifetime was defined as $\tau_{\text{u}} = 1.79 \times 10^6\ \text{eV}^3\text{s}/(\hbar\omega)^3$ and $\tau_{\text{l}} = 0.46 \times 10^6\ \text{eV}^3\text{s}/(\hbar\omega)^3$ at 90% confidence.
- Future work is expected to extend the search to energies below 7.4 eV, requiring either low-energy ALS operation or a VUV laser system for higher spectral irradiance.
Read this paper