Skip to main content
QUICK REVIEW

[Paper Review] Robust Segmentation of Brain MRI in the Wild with Hierarchical CNNs and no Retraining

Benjamin Billot, Magdamo Colin|arXiv (Cornell University)|Mar 3, 2022
Medical Image Segmentation TechniquesComputer Science4 citations
TL;DR

This paper proposes SynthSeg+, a hierarchical CNN framework that enhances robustness for brain MRI segmentation in clinical 'in-the-wild' settings without retraining. By integrating a cascade of conditional segmentation and denoising networks, it achieves state-of-the-art performance, reducing errors on low-SNR and low-contrast scans by up to 23.5 Dice points compared to SynthSeg, and accurately replicates atrophy patterns seen in high-quality research scans.

ABSTRACT

Retrospective analysis of brain MRI scans acquired in the clinic has the potential to enable neuroimaging studies with sample sizes much larger than those found in research datasets. However, analysing such clinical images "in the wild" is challenging, since subjects are scanned with highly variable protocols (MR contrast, resolution, orientation, etc.). Nevertheless, recent advances in convolutional neural networks (CNNs) and domain randomisation for image segmentation, best represented by the publicly available method SynthSeg, may enable morphometry of clinical MRI at scale. In this work, we first evaluate SynthSeg on an uncurated, heterogeneous dataset of more than 10,000 scans acquired at Massachusetts General Hospital. We show that SynthSeg is generally robust, but frequently falters on scans with low signal-to-noise ratio or poor tissue contrast. Next, we propose SynthSeg+, a novel method that greatly mitigates these problems using a hierarchy of conditional segmentation and denoising CNNs. We show that this method is considerably more robust than SynthSeg, while also outperforming cascaded networks and state-of-the-art segmentation denoising methods. Finally, we apply our approach to a proof-of-concept volumetric study of ageing, where it closely replicates atrophy patterns observed in research studies conducted on high-quality, 1mm, T1-weighted scans. The code and trained model are publicly available at https://github.com/BBillot/SynthSeg.

Motivation & Objective

  • To address the challenge of robustly segmenting highly variable clinical brain MRI scans with diverse contrasts, resolutions, and image quality.
  • To overcome the limitations of existing deep learning methods that fail on low-signal-to-noise ratio or poor-contrast scans without requiring retraining.
  • To develop a scalable, general-purpose segmentation framework compatible with large-scale clinical datasets for population-level neuroimaging studies.
  • To enable accurate volumetric analysis of brain atrophy in real-world clinical data, matching results from high-quality research scans.

Proposed method

  • The method employs a hierarchical architecture combining two stages: an initial segmentation network S1 and a refinement network S2, both conditioned on the input MRI.
  • A dedicated denoising CNN D is integrated between S1 and S2 to improve prediction quality by leveraging prior knowledge and reducing noise-induced artifacts.
  • The entire framework is trained end-to-end using domain randomisation on synthetic MRI data, enabling generalisation across diverse contrasts and resolutions without fine-tuning.
  • The approach leverages conditional prediction, where each network uses the input scan and intermediate outputs to refine segmentation progressively.
  • The denoiser D is trained to predict accurate segmentations by learning from both the input image and the predicted mask, improving topological consistency.
  • The framework is designed to be inference-ready on any clinical scan, with no need for retraining or adaptation to new protocols.

Experimental results

Research questions

  • RQ1Can a deep learning-based segmentation method achieve robust performance across highly heterogeneous clinical MRI scans without retraining?
  • RQ2How does a hierarchical architecture combining segmentation and denoising improve robustness on low-SNR and low-contrast scans compared to standard cascaded networks?
  • RQ3To what extent can a no-retraining approach replicate atrophy patterns observed in high-quality research datasets?
  • RQ4Does integrating a denoiser within the inference pipeline improve segmentation accuracy and topological consistency compared to postprocessing denoising?

Key findings

  • SynthSeg+ achieves a 23.5 Dice point improvement over SynthSeg on scans classified as 'Big Fails' (severe segmentation errors), demonstrating exceptional robustness to poor image quality.
  • The method reduces mean surface distance (MSD) by at least 0.35 mm and improves Dice scores by 3 points compared to postprocessing denoising, indicating superior geometric accuracy.
  • On 500 scans with ground truth, SynthSeg+ outperforms both SynthSeg and cascaded networks (S1+S2), especially on low-resolution and low-contrast scans.
  • In a volumetric study of ageing using 10,000 clinical scans, SynthSeg+ produced atrophy trajectories for the cortex and hippocampus that closely matched those from high-quality T1-weighted research scans (1 mm isotropic).
  • The method significantly reduces outlier rates—especially in low-resolution scans—compared to SynthSeg and cascaded networks, enhancing statistical power for population studies.
  • The integration of the denoiser D within the network hierarchy, rather than as a postprocessing step, leads to more accurate and anatomically plausible segmentations.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.