Skip to main content
QUICK REVIEW

[Paper Review] ROSAT X-ray sources in the field of the LMC I.Total LMC gas from the background AGN spectral fits

P. Kahabka, K. S. de Boer|ArXiv.org|Mar 29, 2001
Astrophysical Phenomena and ObservationsPhysics and Astronomy49 references6 citations
TL;DR

This study uses X-ray spectral fitting of 26 background AGN in the ROSAT field of the Large Magellanic Cloud (LMC) to derive total hydrogen column densities due to LMC gas, comparing them with 21-cm H i column densities from Parkes surveys. It finds that 20 sources show good agreement between X-ray and H i columns, while two sources (RX J0536.9-6913 and RX J0547.0-7040) exhibit excess X-ray absorption, suggesting additional cold or molecular gas beyond atomic hydrogen, with molecular mass fraction upper limits of 30–140%.

ABSTRACT

We analyzed a sample of 26 background X-ray sources in a ~60 square degree field of the Large Magellanic Cloud observed with the ROSAT PSPC. The sample has been selected from previously classified and optically identified X-ray sources. In addition pointlike and spectrally hard sources with at least 100 to 200 observed counts have been used for the analysis. We performed X-ray spectral fitting and derived total hydrogen absorbing column densities due to LMC gas in the range 10^20 - 2. 10^21 cm^-2. We compared these columns with the HI columns derived from a 21-cm Parkes survey of the LMC. For 7 optically identified sources we find, within the uncertainties derived from the X-ray spectral fit, agreement for both columns. For further 19 sources we constrain the LMC columns from the X-ray spectral fit assuming that the powerlaw photon index is that of AGN type spectra. We derive for 20 sources gas columns which are within the uncertainties in agreement with the HI columns. We derive for two background sources (RX J0536.9-6913 and RX J0547.0-7040) hydrogen absorbing column densities due to LMC gas, which are in excess to the HI columns. These sources - located in regions of large (~3. 10^21 cm^-2) LMC HI column densities - could be seen through additional gas which may be warm and diffuse, cold or molecular. For 10 sources we derive upper limits for the gas columns additional to HI and constrain the molecular mass fraction to

Motivation & Objective

  • To measure the total hydrogen absorbing column density (N_H) in the line of sight toward background X-ray sources in the LMC field using ROSAT PSPC data.
  • To compare X-ray-derived N_H with atomic hydrogen (H i) column densities from 21-cm Parkes and ATCA surveys to probe the presence of molecular or diffuse gas.
  • To constrain the contribution of molecular hydrogen (H₂) in regions of high H i column density by comparing X-ray spectral fits with radio observations.
  • To assess the significance of excess absorption beyond H i columns in selected sources, potentially indicating cold or molecular gas components.
  • To derive upper limits on the molecular mass fraction in 10 sources where X-ray absorption exceeds H i column density.

Proposed method

  • X-ray spectral fitting of 26 background X-ray sources in a ~60 deg² ROSAT PSPC field toward the LMC, using energy bands 0.4–1.3 keV with exposure correction.
  • For 7 optically identified sources with redshifts, direct spectral fitting was performed to derive photon index (Γ) and N_H, assuming Milky Way foreground absorption is known from 21-cm data.
  • For 19 sources without secure Γ constraints, a fixed power-law index of Γ = 2.0–2.5 (typical of AGN) was assumed to derive N_H from X-ray spectra.
  • H i column densities were derived from 21-cm Parkes and ATCA surveys, with spatial resolution ~15′ and 1′ respectively.
  • Excess absorption beyond H i columns was interpreted as potential contribution from molecular or warm diffuse gas, with molecular mass fraction estimated using a standard X-factor (X = 2×10²⁰ cm⁻² (K km s⁻¹)⁻¹).
  • Upper limits on molecular gas were derived by comparing X-ray N_H (total) with H i N_H, assuming any excess is due to H₂.

Experimental results

Research questions

  • RQ1Do X-ray-derived total hydrogen column densities in the LMC direction agree with 21-cm H i column densities from radio surveys?
  • RQ2Are there lines of sight where X-ray absorption exceeds H i column density, indicating additional gas components?
  • RQ3What is the upper limit on the molecular hydrogen mass fraction in regions with excess X-ray absorption?
  • RQ4How significant is the excess absorption in two sources (RX J0536.9-6913 and RX J0547.0-7040) beyond H i columns, and what does it imply about gas composition?
  • RQ5Can X-ray spectral fitting of background AGN provide reliable constraints on the total ISM column density in the LMC, even when AGN parameters are uncertain?

Key findings

  • For 20 of the 26 background X-ray sources, the X-ray-derived total hydrogen column density (N_H) is consistent with the H i column density from 21-cm surveys within uncertainties.
  • For RX J0536.9-6913 and RX J0547.0-7040, X-ray spectral fitting yields N_H ≈ (0.6–2.0)×10²² cm⁻², which exceeds the H i column density of ~3×10²¹ cm⁻², indicating excess absorption.
  • The excess absorption in these two sources is interpreted as evidence for additional gas, possibly molecular or warm/diffuse, beyond atomic hydrogen.
  • For 10 sources, upper limits on additional gas columns were derived, translating to molecular mass fraction upper limits of 30–140% when assuming standard X-factor.
  • The derived molecular mass fraction limits are consistent with low CO detection limits, as the implied CO intensity (0.35 K km s⁻¹) is below the detection threshold of the NANTEN 12 CO survey.
  • The results support the use of X-ray spectral fitting of background AGN as a probe of total ISM column density in the LMC, even when AGN parameters are not fully constrained.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.