Skip to main content
QUICK REVIEW

[Paper Review] RSNA Large Language Model Benchmark Dataset for Chest Radiographs of Cardiothoracic Disease: Radiologist Evaluation and Validation Enhanced by AI Labels (REVEAL-CXR)

Yishu Wei, Adam E. Flanders|arXiv (Cornell University)|Jan 21, 2026
Artificial Intelligence in Healthcare and EducationMedicine0 citations
TL;DR

REVEAL-CXR curates a radiologist-verified benchmark of 200 chest radiographs (100 released, 100 holdout) with 12 cardiothoracic labels, using AI-assisted labeling to speed expert annotation for evaluating multimodal LLMs.

ABSTRACT

Multimodal large language models have demonstrated comparable performance to that of radiology trainees on multiple-choice board-style exams. However, to develop clinically useful multimodal LLM tools, high-quality benchmarks curated by domain experts are essential. To curate released and holdout datasets of 100 chest radiographic studies each and propose an artificial intelligence (AI)-assisted expert labeling procedure to allow radiologists to label studies more efficiently. A total of 13,735 deidentified chest radiographs and their corresponding reports from the MIDRC were used. GPT-4o extracted abnormal findings from the reports, which were then mapped to 12 benchmark labels with a locally hosted LLM (Phi-4-Reasoning). From these studies, 1,000 were sampled on the basis of the AI-suggested benchmark labels for expert review; the sampling algorithm ensured that the selected studies were clinically relevant and captured a range of difficulty levels. Seventeen chest radiologists participated, and they marked "Agree all", "Agree mostly" or "Disagree" to indicate their assessment of the correctness of the LLM suggested labels. Each chest radiograph was evaluated by three experts. Of these, at least two radiologists selected "Agree All" for 381 radiographs. From this set, 200 were selected, prioritizing those with less common or multiple finding labels, and divided into 100 released radiographs and 100 reserved as the holdout dataset. The holdout dataset is used exclusively by RSNA to independently evaluate different models. A benchmark of 200 chest radiographic studies with 12 benchmark labels was created and made publicly available https://imaging.rsna.org, with each chest radiograph verified by three radiologists. In addition, an AI-assisted labeling procedure was developed to help radiologists label at scale, minimize unnecessary omissions, and support a semicollaborative environment.

Motivation & Objective

  • Provide a high-quality, expert-annotated chest radiograph benchmark focused on cardiothoracic findings.
  • Demonstrate an AI-assisted labeling workflow to scale radiologist annotation.
  • Ensure balanced, multicenter, multi-institutional data with a holdout set for independent model evaluation.

Proposed method

  • Use GPT-4o to extract abnormal findings from radiology reports.
  • Map extracted findings to 12 predefined benchmark labels using a locally hosted Phi-4-Reasoning model.
  • Stratified sampling to select studies with AI-suggested labels for expert review (1–6 labels per study).
  • Have 17 radiologists from 10 institutions adjudicate labels via a web platform (Agree All / Agree Mostly / Disagree).
  • Retain only studies with at least two Agree All ratings, producing 381 studies; select 100 released and 100 holdout datasets.
  • Compute interrater agreement with Cohen’s kappa and bootstrap CIs; compare radiologists to majority-voted references.

Experimental results

Research questions

  • RQ1Can an AI-assisted labeling workflow produce reliable radiologist-verified labels for chest radiographs?
  • RQ2What is the interrater reliability among radiologists for a 12-label cardiothoracic chest radiograph benchmark?
  • RQ3How do radiologist labels compare to AI-suggested labels on a held-out, multicenter chest radiograph dataset?
  • RQ4Are the released and holdout subsets imaging-acquisition balanced to allow fair model evaluation?
  • RQ5What are the limitations and potential roles of such a benchmark for multimodal LLM evaluation?

Key findings

  • A benchmark of 200 chest radiographs with 12 labels was created and publicly released, with three radiologists reviewing each study.
  • Cohen’s kappa for interrater agreement among radiologists (binary Agree/Disagree) is 0.622 (95% CI 0.590, 0.651).
  • Airspace opacity shows lower agreement (kappa = 0.484, 95% CI [0.440, 0.524]); most findings have kappa between 0.744 and 0.809.
  • In 619/1,000 cases (61.9%), the majority voted to Disagree with the LLM-suggested labels, indicating frequent divergence from AI labels.
  • Released vs holdout subsets show no significant differences in acquisition properties (Chi-square p-values all >0.05).
  • The dataset emphasizes rare or multiple findings, with 381 studies meeting two-Three radiologist agreements.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.