Skip to main content
QUICK REVIEW

[Paper Review] Search for sub-GeV Dark Matter via Migdal effect with an EDELWEISS germanium detector with NbSi TES sensors

E. Armengaud, Q. Arnaud|arXiv (Cornell University)|Mar 8, 2022
Dark Matter and Cosmic PhenomenaPhysics and Astronomy2 citations
TL;DR

This paper presents a search for sub-GeV dark matter using the Migdal effect in a 200 g germanium detector equipped with NbSi transition edge sensor (TES) phonon readout, achieving a 30 eVee energy threshold. The experiment, conducted underground at Modane with ultra-low background, sets new constraints on spin-independent dark matter-nucleus cross-sections down to 10⁻²⁹ cm² for masses between 32 and 100 MeV·c⁻².

ABSTRACT

The EDELWEISS collaboration reports on the search for Dark Matter (DM) particle interactions via Migdal effect with masses between $32$ MeV$\cdot$c$^{-2}$ to $2$ GeV$\cdot$c$^{-2}$ using a $200$ g cryogenic Ge detector sensitive to simultaneously heat and ionization signals and operated underground at the Laboratoire Souterrain de Modane in France. The phonon signal was read out using a Transition Edge Sensor made of a NbSi thin film. The detector was biased at $66$ V in order to benefit from the Neganov-Trofimov-Luke amplification and resulting in a resolution on the energy of electron recoils of $4.46$ eV$_{ee}$ (RMS) and an analysis threshold of $30$ eV$_{ee}$. The sensitivity is limited by a dominant background not associated to charge creation in the detector. The search constrains a new region of parameter space for cross-sections down to $10^{-29}$ cm$^2$ and masses between $32$ and $100$ MeV$\cdot$c$^{-2}$. The achieved low threshold with the NbSi sensor shows the relevance of its use for athermal-phonon sensitive devices for low-mass DM searches.

Motivation & Objective

  • To extend the sensitivity of direct dark matter searches to sub-GeV masses below the traditional 1 GeV·c⁻² threshold.
  • To test the feasibility of the Migdal effect as a detection mechanism for low-mass dark matter via electron ionization.
  • To reduce background from Heat-Only (HO) events through use of NbSi TES sensors instead of Ge-NTD thermistors.
  • To achieve a sub-100 eV energy threshold for electron recoil signals to probe low-mass dark matter.
  • To constrain the spin-independent dark matter-nucleus scattering cross-section in the 32–100 MeV·c⁻² mass range.

Proposed method

  • Utilized a 200 g high-purity germanium crystal with a NbSi thin-film transition edge sensor (TES) for phonon readout.
  • Operated the detector at the EDELWEISS-III underground site (LSM, 4800 m.w.e.) to minimize cosmic and radioactive backgrounds.
  • Applied a 66 V bias to exploit Neganov-Trofimov-Luke (NTL) amplification for enhanced signal-to-noise in the TES response.
  • Performed simultaneous measurement of heat and ionization signals to distinguish electron recoils from nuclear recoils and suppress HO events.
  • Calibrated the detector using ⁵⁷Co and ⁶⁵Zn sources to determine energy resolution and threshold.
  • Used a Bayesian analysis framework with a likelihood model based on the expected Migdal effect signal and background components.

Experimental results

Research questions

  • RQ1Can the Migdal effect be used to detect dark matter particles with masses below 1 GeV·c⁻²?
  • RQ2Can NbSi TES sensors achieve a sub-100 eV energy threshold for electron recoil detection in germanium?
  • RQ3What is the impact of Heat-Only (HO) events on low-mass dark matter searches, and can they be suppressed using NbSi TES?
  • RQ4What are the resulting constraints on the spin-independent dark matter-nucleus scattering cross-section in the 32–100 MeV·c⁻² mass range?
  • RQ5How does the NTL amplification effect improve sensitivity in low-threshold TES-based detectors?

Key findings

  • The detector achieved a 30 eVee analysis threshold and a 4.46 eVee energy resolution (RMS) at 66 V bias.
  • The dominant background was identified as Heat-Only (HO) events not associated with charge creation, consistent with prior EDELWEISS results.
  • The experiment set new exclusion limits on the spin-independent dark matter-nucleus scattering cross-section, reaching down to 10⁻²⁹ cm² for masses between 32 and 100 MeV·c⁻².
  • The use of NbSi TES sensors significantly reduced sensitivity to HO events compared to previous Ge-NTD sensors.
  • The results demonstrate the viability of NbSi TES for future low-mass dark matter searches with sub-100 eV thresholds.
  • The study confirms that the Migdal effect provides a powerful pathway to probe the sub-GeV dark matter parameter space.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.