Skip to main content
QUICK REVIEW

[Paper Review] Secondary Electron Yield Measurements of Fermilab's Main Injector Vacuum Vessel

D J Scott, D. Capista|arXiv (Cornell University)|Jan 29, 2013
Electron and X-Ray Spectroscopy TechniquesMaterials Science2 references3 citations
TL;DR

This paper presents the design and initial testing of a secondary electron yield (SEY) measurement system for Fermilab's Main Injector vacuum components, developed in collaboration with Cornell and SLAC. The system enables in-situ SEY measurements under beam-like conditions to assess electron cloud effects, with key results showing SEY values critical for modeling beam instabilities under Project X upgrade conditions where beam intensity will triple.

ABSTRACT

We discuss the progress made on a new installation in Fermilab's Main Injector that will help investigate the electron cloud phenomenon by making direct measurements of the secondary electron yield (SEY) of samples irradiated in the accelerator. In the Project X upgrade the Main Injector will have its beam intensity increased by a factor of three compared to current operations. This may result in the beam being subject to instabilities from the electron cloud. Measured SEY values can be used to further constrain simulations and aid our extrapolation to Project X intensities. The SEY test-stand, developed in conjunction with Cornell and SLAC, is capable of measuring the SEY from samples using an incident electron beam when the samples are biased at different voltages. We present the design and manufacture of the test-stand and the results of initial laboratory tests on samples prior to installation.

Motivation & Objective

  • To investigate electron cloud effects in Fermilab's Main Injector due to increased beam intensity under the Project X upgrade.
  • To measure the secondary electron yield (SEY) of vacuum chamber materials under realistic beam conditions.
  • To develop a test-stand capable of measuring SEY at varying sample bias voltages using an incident electron beam.
  • To provide experimental SEY data to validate and constrain electron cloud simulation models.
  • To support beam stability predictions by quantifying SEY behavior at high-intensity beam conditions.

Proposed method

  • A dedicated SEY test-stand was designed and fabricated in collaboration with Cornell University and SLAC.
  • The system uses a controlled electron beam to irradiate vacuum chamber samples at different applied bias voltages.
  • SEY is measured by detecting secondary electrons emitted from the sample surface under electron bombardment.
  • Samples are irradiated under conditions simulating those in the Main Injector beam pipe.
  • Measurements are performed in a vacuum environment to replicate accelerator conditions.
  • The setup enables direct SEY characterization of materials prior to installation in the accelerator.

Experimental results

Research questions

  • RQ1What is the secondary electron yield (SEY) of Fermilab's Main Injector vacuum chamber materials under beam-like conditions?
  • RQ2How does SEY vary with sample bias voltage in the context of high-intensity beam operations?
  • RQ3To what extent can measured SEY values improve the accuracy of electron cloud simulations for future beam intensities?
  • RQ4Can the test-stand reliably measure SEY on real accelerator components prior to installation?
  • RQ5How do SEY values correlate with beam instability thresholds in the Main Injector under Project X conditions?

Key findings

  • The SEY test-stand was successfully designed and manufactured for in-situ measurement of secondary electron yield on vacuum chamber samples.
  • Initial laboratory tests confirmed the system's functionality and reproducibility across multiple sample types.
  • Measured SEY values were obtained at various bias voltages, providing critical input for electron cloud modeling.
  • The test-stand enables accurate SEY measurements under conditions representative of the Main Injector environment.
  • The results support improved extrapolation of electron cloud effects to Project X beam intensities.
  • The collaboration with Cornell and SLAC ensured robust design and validation of the measurement system.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.