Skip to main content
QUICK REVIEW

[Paper Review] Shower Studies at around 10^18 eV with the Surface Detector of the Pierre Auger Observatory

Piera Luisa Ghia, For The Pierre Auger Collaboration|arXiv (Cornell University)|Aug 25, 2003
Astrophysics and Cosmic PhenomenaPhysics and Astronomy1 citations
TL;DR

This study validates a trigger and reconstruction procedure for detecting extensive air showers at ~10^18 eV using the Pierre Auger Observatory's Engineering Array surface detector. By optimizing a 3-fold trigger with 2 Hz single-tank rate and 5 µs coincidence window, the team achieved a stable event rate of 6.3 ± 0.4/day, consistent with expectations from cosmic ray flux models, confirming the detector's readiness for high-energy shower studies at the 10^18 eV threshold.

ABSTRACT

Three months of data taken by the Engineering Array Surface Detector of the Pierre Auger Observatory have been analyzed with the aim of setting a procedure for the study of showers at E_0 ~ 10^18 eV. We present the results, concerning: (i) the selection procedure and the check of its efficiency; (ii) the event rate and its stability; (iii) the characteristics of such events (i.e., angular direction, energy estimator S(1000), rise time vs core distance, correlation with pressure) showing their consistency with the expectations. The performances of the whole Surface Detector of the Auger Observatory are discussed.

Motivation & Objective

  • To establish a reliable selection procedure for extensive air showers at ~10^18 eV using the Auger Surface Detector.
  • To verify the stability and consistency of the event rate with theoretical expectations from the cosmic ray spectrum.
  • To validate shower parameter reconstruction (energy, direction, rise time) against simulations and data from other experiments.
  • To calibrate the surface detector performance for future full-scale operation at the 10^18 eV energy range.
  • To assess the detector's sensitivity to anisotropy and atmospheric pressure effects at this energy scale.

Proposed method

  • Used data from 32 surface detector stations (Engineering Array) operating from May to July 2002.
  • Applied a 3-fold trigger with optimized single-tank rate (ft ≈ 2 Hz) and coincidence window (Δt ≈ 5 µs) to suppress accidental coincidences.
  • Calibrated trigger efficiency using a WCD prototype correlated with AGASA data, extrapolated to 10^18 eV.
  • Reconstructed shower parameters including zenith angle (θ), azimuthal angle (φ), S(1000) estimator, and rise time (t50−t10) vs core distance.
  • Compared measured event rates and shower parameters with simulated data and results from Haverah Park and AGASA.
  • Analyzed pressure dependence of event rate to validate atmospheric corrections, yielding a pressure coefficient k = -0.011 ± 0.005 mbar⁻¹.

Experimental results

Research questions

  • RQ1Can a 3-fold trigger with low single-tank rate (2 Hz) effectively isolate cosmic ray showers at ~10^18 eV while suppressing accidental coincidences?
  • RQ2Is the measured event rate consistent with the expected flux of cosmic rays at 10^18 eV, given the detector acceptance and trigger efficiency?
  • RQ3Do the reconstructed shower parameters (θ, φ, S(1000), rise time vs. core distance) match expectations from simulations and other experiments?
  • RQ4What is the sensitivity of the event rate to atmospheric pressure, and is this effect consistent with known atmospheric corrections?
  • RQ5Can the detector system reliably detect anisotropies in the cosmic ray flux at this energy scale?

Key findings

  • The measured daily event rate of 6.3 ± 0.4 events (θ < 45°) is consistent with the expected rate of 5 ± 1/day from cosmic ray showers at ~10^18 eV.
  • The event rate distribution is compatible with a Poisson process (χ² = 1.5/d.f.), indicating stable detector operation over the three-month period.
  • The reconstructed zenith angle distribution (mean 30.9°, RMS 12.96°) and azimuthal angle distribution (mean -5.585°, RMS 104.3°) are consistent with isotropic expectations.
  • The S(1000) estimator distribution (mean 0.6833 VEM, RMS 0.288) corresponds to primary energies between 0.4 and 0.9 × 10^18 eV, in agreement with current knowledge of the cosmic ray spectrum.
  • The rise time (t50−t10) vs. core distance shows good agreement with simulations and Haverah Park data, confirming detector response fidelity.
  • The pressure coefficient k = -0.011 ± 0.005 mbar⁻¹ is significant at 2σ and consistent with previous results from Haverah Park, validating atmospheric correction models.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.