Skip to main content
QUICK REVIEW

[Paper Review] SlideRunner - A Tool for Massive Cell Annotations in Whole Slide Images

Marc Aubreville, Christof Bertram|arXiv (Cornell University)|Feb 7, 2018
Cell Image Analysis TechniquesBiochemistry, Genetics and Molecular Biology10 references10 citations
TL;DR

SlideRunner is an open-source, interactive tool for high-throughput, multi-expert annotation of whole-slide histology images, enabling fast, blinded cell annotations via one-click labeling and guided screening. It significantly accelerates mitosis detection annotation—reducing mean annotation time to 2.0–2.6 seconds per label—while supporting curriculum learning through multi-annotator consensus and improved data quality for deep learning applications.

ABSTRACT

Large-scale image data such as digital whole-slide histology images pose a challenging task at annotation software solutions. Today, a number of good solutions with varying scopes exist. For cell annotation, however, we find that many do not match the prerequisites for fast annotations. Especially in the field of mitosis detection, it is assumed that detection accuracy could significantly benefit from larger annotation databases that are currently however very troublesome to produce. Further, multiple independent (blind) expert labels are a big asset for such databases, yet there is currently no tool for this kind of annotation available. To ease this tedious process of expert annotation and grading, we introduce SlideRunner, an open source annotation and visualization tool for digital histopathology, developed in close cooperation with two pathologists. SlideRunner is capable of setting annotations like object centers (for e.g. cells) as well as object boundaries (e.g. for tumor outlines). It provides single-click annotations as well as a blind mode for multi-annotations, where the expert is directly shown the microscopy image containing the cells that he has not yet rated.

Motivation & Objective

  • To address the critical bottleneck in digital pathology: the time-consuming, low-throughput annotation of rare or complex cell types like mitotic figures in whole-slide images.
  • To enable high-quality, multi-annotator labeling with blinded consensus to reduce inter-observer variance and improve ground truth reliability.
  • To develop a user-friendly, interactive tool that supports rapid, one-click annotations and guided screening for complete image coverage.
  • To create large-scale, high-quality annotated databases essential for training robust deep learning models in histopathology.
  • To support curriculum learning by identifying prototypical vs. difficult samples through expert disagreement analysis.

Proposed method

  • SlideRunner uses a dual-mode interface: standard annotation mode for direct labeling and blinded mode where prior annotators' labels are hidden, ensuring independent expert evaluation.
  • It implements a discovery mode that automatically presents unannotated image regions to reduce navigation time and increase annotation throughput.
  • A guided screening mode uses grid-based segmentation of the slide, excluding empty regions via thresholding and morphological operations, to systematically present tissue-containing fields for review.
  • Annotations are stored with multiple coordinates (e.g., points or polygons) and multiple labels per object from different annotators, enabling consensus and difficulty assessment.
  • The tool supports both point-based (e.g., cell centers) and boundary-based (e.g., tumor outlines) annotations using click-and-drag or single-click methods.
  • The database model stores each annotation with its spatial coordinates, order of creation, and per-annotator class labels, enabling detailed analysis of inter-rater variability.

Experimental results

Research questions

  • RQ1Can a blinded, multi-annotator annotation system reduce inter-observer variance and improve label reliability in whole-slide image analysis?
  • RQ2To what extent does guided screening and discovery mode improve annotation speed and completeness compared to free-form navigation?
  • RQ3How does the time efficiency of SlideRunner compare to conventional annotation methods in real-world pathologist workflows?
  • RQ4Can multi-annotator consensus data from SlideRunner support curriculum learning by identifying prototypical vs. ambiguous cell instances?
  • RQ5What is the impact of annotation mode (guided vs. free) on the total number of detected mitotic figures in a given slide?

Key findings

  • Mean annotation time for first annotations was 6.6 seconds and 6.3 seconds per label for two pathologists, dropping to 2.0 and 2.6 seconds for second annotations, indicating significant learning and efficiency gains.
  • Cohen’s weighted kappa of 0.815 indicated substantial agreement between two pathologists on cell type classification, with the highest disagreement occurring between clear classes and the ambiguous class.
  • Guided screening led to a 90% increase in mitotic figure detection (4,233 vs. 2,252) on the same slide compared to manual free-form annotation, suggesting improved completeness and reduced oversight.
  • The tool enabled the creation of a double-annotated, large-scale database of canine mast cell tumor slides with over 71,000 labels, supporting high-quality training for machine learning.
  • Blind annotation mode effectively supported independent labeling, with hidden class labels preventing bias and enabling reliable consensus estimation.
  • The system’s ability to handle very large whole-slide images using on-demand loading and efficient data structures supports scalable, real-world deployment in pathology workflows.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.