TL;DR

This paper presents FAMOUS, a prototype fluorescence telescope for ultra-high-energy cosmic ray (UHECR) detection using silicon photomultipliers (SiPMs) instead of traditional photomultiplier tubes. The telescope uses a 549.7 mm Fresnel lens and 64 SiPM pixels with Winston cone light concentrators to achieve 100% detection efficiency for 10^18 eV showers up to 6 km distance, validated by Geant4 simulations, demonstrating SiPM feasibility for next-generation UHECR instruments.

ABSTRACT

An established technique for the measurement of ultra-high-energy-cosmic-rays is the detection of the fluorescence light induced in the atmosphere of the Earth, by means of telescopes equipped with photomultiplier tubes. Silicon photomultipliers (SiPMs) promise an increase in the photon detection efficiency which outperforms conventional photomultiplier tubes. In combination with their compact package, a moderate bias voltage of several ten volt and single photon resolution, the use of SiPMs can improve the energy and spatial resolution of air fluorescence measurements, and lead to a gain in information on the primary particle. Though, drawbacks like a high dark-noise-rate and a strong temperature dependency have to be managed. FAMOUS is a refracting telescope prototype instrumented with 64 SiPMs of which the main optical element is a Fresnel lens of 549.7 mm diameter and 502.1 mm focal length. The sensitive area of the SiPMs is increased by a special light collection system consisting of Winston cones. The total field of view of the telescope is approximately 12 $^\\circ$. The frontend electronics automatically compensates for the temperature dependency of the SiPMs and will provide trigger information for the readout. Already for this prototype, the Geant4 detector simulation indicates full detection efficiency of extensive air showers of $E=10^{18}\\,\ ext{eV}$ up to a distance of 6 km. We present the first working version of FAMOUS with a focal plane prototype providing seven active pixels.

Motivation & Objective

  • To demonstrate the feasibility of silicon photomultipliers (SiPMs) in fluorescence telescopes for ultra-high-energy cosmic ray (UHECR) detection.
  • To overcome limitations of conventional photomultiplier tubes by leveraging SiPMs' higher photon detection efficiency, compact size, and single-photon resolution.
  • To develop a scalable, low-noise, temperature-stabilized front-end electronics system for SiPM-based fluorescence telescopes.
  • To validate the performance of the FAMOUS prototype through Geant4 and CONEX simulations, assessing trigger efficiency for extensive air showers.
  • To test the first seven-pixel version (FAMOUS^SEVEN) and prepare for full 64-pixel implementation.

Proposed method

  • The telescope uses a 549.7 mm diameter Fresnel lens with 502.1 mm focal length to focus fluorescence light onto a focal plane of 64 SiPM pixels.
  • Each SiPM pixel is an array of four 3×3 mm² Hamamatsu S10362-33-100C SiPMs with 100 µm cell pitch, increasing sensitive area via light concentrators.
  • Winston cone concentrators with 6.71 mm entrance radius and 3 mm exit radius collect light up to 26.6° incidence angle with >90% transmission efficiency.
  • Frontend electronics include automatic temperature compensation for SiPM gain and a programmable FPGA for trigger generation.
  • Detector response is simulated using Geant4 with air shower inputs from CONEX, modeling photon yield, propagation, and detection efficiency.
  • Signal characterization is performed via pulsed LED illumination (400 nm, 20 ns pulse) and charge-to-digital conversion (QDC) to calibrate gain and resolve photon-equivalent peaks.

Experimental results

Research questions

  • RQ1Can SiPMs achieve sufficient detection efficiency for 10^18 eV extensive air showers at distances up to 6 km in a fluorescence telescope?
  • RQ2How does the combination of Fresnel lens optics and Winston cone concentrators enhance light collection efficiency for SiPMs?
  • RQ3To what extent do temperature-dependent gain variations and noise (crosstalk, afterpulsing, dark counts) affect signal fidelity in SiPM-based fluorescence detection?
  • RQ4Can the FAMOUS prototype achieve full detection efficiency for vertical showers at 6 km distance, as predicted by simulation?
  • RQ5Is the first seven-pixel prototype (FAMOUS^SEVEN) capable of resolving single-photon signals for calibration and performance validation?

Key findings

  • The FAMOUS prototype achieves full detection efficiency for 10^18 eV extensive air showers at a distance of up to 6 km, as confirmed by Geant4 simulations.
  • The first operational version, FAMOUS^SEVEN, successfully resolves individual photon-equivalent peaks in charge spectra from pulsed 400 nm LED illumination, confirming single-photon resolution capability.
  • The SiPM-based system demonstrates stable signal response with a measured photon detection efficiency of 33.1% at 420 nm and 1.3 V over-voltage.
  • The use of Winston cone concentrators increases effective sensitive area and maintains >90% light transmission for incident angles up to 26.6°.
  • The front-end electronics successfully compensate for temperature-induced gain drift, enabling stable operation under varying environmental conditions.
  • Simulations indicate that FAMOUS could detect several tens of UHECR showers per night at 6 km distance, even under night-sky background conditions with radiance ≤1.9×10^12 m⁻²s⁻¹sr⁻¹.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.