Skip to main content
QUICK REVIEW

[Paper Review] Status Report (BKG measurement): A Search for Sterile Neutrino at J-PARC MLF

Masahide Harada, S. Hasegawa|arXiv (Cornell University)|Feb 8, 2015
Neutrino Physics ResearchPhysics and Astronomy3 references12 citations
TL;DR

This paper reports on a background measurement campaign at J-PARC's MLF 3rd floor to assess feasibility for a sterile neutrino search using inverse beta decay in liquid scintillator detectors. Using a 500 kg plastic scintillator and small-scale detectors, the team measured beam-associated fast neutrons and accidental backgrounds, validating Monte Carlo simulations and confirming that background rates are manageable for the P56 experiment with optimized selection cuts, enabling sensitivity to sterile neutrino oscillations at Δm² ≈ 3.0 eV².

ABSTRACT

At the 17th J-PARC PAC, which was held on September 2013, we proposed the sterile neutrino search at J-PARC MLF. After reviewing the proposal, PAC recommended to have a background measurement at the detector's candidate site location in their report to investigate whether the background rates can be manageable for the real experiment or not. Therefore, we have performed the background measurements (MLF; 2013BU1301 test experiment) during the summer of 2014, also following the 18th J-PARC PAC recommendations, and the measurements results are described here.

Motivation & Objective

  • To evaluate background rates from beam-associated fast neutrons and accidental coincidences at the P56 experiment site on the MLF 3rd floor.
  • To validate Monte Carlo simulations of background rates using direct measurements with a 500 kg plastic scintillator and small detectors.
  • To confirm the feasibility of the P56 experiment for detecting sterile neutrino oscillations via inverse beta decay (IBD) signals.
  • To optimize selection criteria for IBD events to suppress background while preserving signal efficiency.
  • To provide a data-driven basis for sensitivity estimates and experimental design in the P56 sterile neutrino search.

Proposed method

  • Conducted background measurements at the MLF 3rd floor during summer 2014 using a 500 kg plastic scintillator and small detectors (NaI, NE213, plastic scintillator).
  • Measured beam-associated fast neutrons and accidental coincidence backgrounds using time- and energy-sliced data, with 3.5 μs gate window to avoid beam bunch effects.
  • Used a 65 MHz FADC system to digitize PMT waveforms and apply energy calibration via cosmic muon peaks (9 MeV, 18% resolution).
  • Employed lead shielding configurations (0, 5, 10 cm) to measure gamma rejection power and validate MC models.
  • Calibrated MC simulations using measured event rates and energy spectra, normalizing to data in the 4–10 MeV range.
  • Applied selection cuts from the P56 proposal: Δt_prompt (1–10 μs), Edelayed (6–12 MeV), Eprompt (20–60 MeV), Δtdelayed ≤ 100 μs, and ΔVtx ≤ 60 cm.

Experimental results

Research questions

  • RQ1Can beam-associated fast neutron and accidental background rates at the MLF 3rd floor be managed within the sensitivity requirements of the P56 sterile neutrino experiment?
  • RQ2How well do Monte Carlo simulations reproduce measured background rates and energy spectra for gammas and fast neutrons?
  • RQ3To what extent do lead shielding and selection cuts reduce background while preserving IBD signal efficiency?
  • RQ4Is the background level from beam and cosmic rays consistent with the P56 proposal’s assumptions, or do they require revision?
  • RQ5What is the effective rejection power of shielding and cuts for gamma and neutron backgrounds in the P56 detector configuration?

Key findings

  • The measured beam-associated fast neutron rate was 1.12 × 10⁻³ Hz (statistical uncertainty ±0.04 × 10⁻³ Hz), in good agreement with the MC prediction of 1.12 × 10⁻³ Hz.
  • Gamma background rates were measured at 1.18 ± 0.04 × 10⁻³ Hz (4–10 MeV), consistent with the MC prediction of 0.95 × 10⁻³ Hz within 20%.
  • The MC model for gamma backgrounds was validated: rejection power and energy spectra matched measurements across all lead shielding configurations.
  • The 5-cm and 10-cm lead shields reduced gamma-induced events by factors of 12.5 and 15.5, respectively, confirming effective shielding.
  • After applying all P56 selection cuts, the total background rate was estimated at 37 events per 4 years for 50 tons of fiducial mass, consistent with the proposal's baseline.
  • The validation of MC simulations and measured background rates supports the feasibility of the P56 experiment for detecting sterile neutrinos with sin²2θ ≈ 3.0 × 10⁻³ at Δm² ≈ 3.0 eV².

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.