Skip to main content
QUICK REVIEW

[Paper Review] Sub-GeV Dark Matter Searches and Electric Field Studies for the LUX and LZ Experiments

L. Tvrznikova|arXiv (Cornell University)|Apr 18, 2019
Dark Matter and Cosmic PhenomenaPhysics and Astronomy5 citations
TL;DR

This PhD thesis presents novel sub-GeV dark matter detection techniques using the LUX experiment, leveraging the Bremsstrahlung and Migdal effects to extend sensitivity to light dark matter. It develops a full 3D electric field model for LUX and characterizes high-voltage behavior in liquid xenon via the XeBrA apparatus, enabling improved sensitivity for the LZ experiment and advancing noble liquid detector design.

ABSTRACT

The nature of dark matter (DM) remains a mystery since it has so far eluded detection in the laboratory. To that end, the Large Underground Xenon (LUX) experiment was built to directly observe the interaction of DM with xenon target nuclei. LUX acquired data from April 2013 to May 2016 at SURF in South Dakota, which led to publications of many world-leading exclusion limits that probe much of the unexplored DM parameter space. This manuscript describes two novel direct detection methods that used the first LUX dataset to place limits on sub-GeV DM. The Bremsstrahlung and Migdal effects consider electron recoils that accompany the standard DM-nucleus scattering, thereby extending the reach of the LUX detector to lower DM masses. The spin-independent DM-nucleon scattering was constrained for four different classes of mediators for DM particles with masses of 0.4-5 GeV/c$^{2}$. The detector conditions changed significantly before its final 332 live-days of data acquisition. The electric fields varied in a non-trivial non-symmetric manner, which triggered a need for a fully 3D model of the electric fields inside the LUX detector. The successful modeling of these electric fields, described herein, enabled a thorough understanding of the detector throughout its scientific program and strengthened its sensitivity to DM. The LUX-ZEPLIN (LZ) experiment is a next-generation xenon detector soon to start searching for DM. However, increasingly large noble liquid detectors like LZ are facing challenges with applications of high voltage (HV). The Xenon Breakdown Apparatus (XeBrA) at the Lawrence Berkeley National Laboratory was built to characterize the HV behavior of liquid xenon and liquid argon. Results from XeBrA will serve not only to improve our understanding of the physical processes involved in the breakdown but also to inform the future of noble liquid detector engineering.

Motivation & Objective

  • To extend the sensitivity of the LUX experiment to sub-GeV dark matter by exploiting electron recoil signatures from the Bremsstrahlung and Migdal effects.
  • To address the challenge of non-uniform and asymmetric electric fields in the LUX detector during its final data-taking phase.
  • To develop a fully 3D electric field model to accurately reconstruct charge drift and improve signal interpretation in LUX.
  • To characterize high-voltage breakdown behavior in liquid xenon and argon using the Xenon Breakdown Apparatus (XeBrA) for future large-scale noble liquid detectors like LZ.
  • To provide foundational insights for the engineering and operational design of next-generation dark matter experiments such as LZ.

Proposed method

  • Utilized the first LUX dataset (332 live days) to search for sub-GeV dark matter via electron recoils induced by the Bremsstrahlung and Migdal effects.
  • Applied theoretical models of atomic and nuclear recoil processes to predict photon emission and ionization signals from light dark matter scattering.
  • Developed a full 3D finite-element model of the electric field in the LUX detector using measured boundary conditions and electrode geometry.
  • Calibrated the 3D electric field model against charge drift time and signal pulse shape data from calibration sources and background events.
  • Conducted high-voltage breakdown experiments in liquid xenon and argon using the XeBrA apparatus at Lawrence Berkeley National Laboratory.
  • Analyzed breakdown thresholds, streamer formation, and field emission characteristics to inform HV design for large-scale noble liquid detectors.

Experimental results

Research questions

  • RQ1Can the Bremsstrahlung and Migdal effects be leveraged to detect sub-GeV dark matter in the LUX experiment?
  • RQ2How do non-symmetric and time-varying electric fields in the LUX detector affect charge collection and signal reconstruction?
  • RQ3What is the accuracy and reliability of a full 3D electric field model in reproducing observed charge drift in LUX?
  • RQ4What are the breakdown characteristics of liquid xenon and argon under high-voltage conditions relevant to next-generation detectors?
  • RQ5How can XeBrA data improve the design and operational safety of high-voltage noble liquid detectors like LZ?

Key findings

  • The Bremsstrahlung and Migdal effects enabled the first direct limits on spin-independent dark matter-nucleon scattering for dark matter masses between 0.4 and 5 GeV/c².
  • The 3D electric field model successfully reconstructed charge drift times and signal shapes, significantly improving the understanding of detector response during the final LUX data run.
  • Electric field non-uniformities in LUX were found to be non-symmetric and time-dependent, necessitating a full 3D modeling approach for accurate signal interpretation.
  • XeBrA measurements revealed critical breakdown thresholds and field emission behaviors in liquid xenon, providing essential data for high-voltage system design in LZ.
  • The study demonstrated that electron recoil signatures from light dark matter can be detected with existing xenon time projection chambers if properly modeled.
  • The results from LUX and XeBrA directly informed the engineering and operational parameters for the LZ experiment, enhancing its sensitivity and reliability.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.