TL;DR

SYMPA is a ground-based Fourier transform spectrometer designed to detect Jupiter's free oscillations via Doppler shift mapping of its visible disk. Despite technical limitations, it achieved a velocity noise floor of 12 cm s⁻¹ over a 10-night run—five times better than prior efforts—though no clear oscillation signals were detected due to signal dilution from mode degeneracy and low duty cycle (21%).

ABSTRACT

Context. Due to its great mass and its rapid formation, Jupiter has played a crucial role in shaping the Solar System. The knowledge of its internal structure would strongly constrain the solar system formation mechanism. Seismology is the most efficient way to probe directly the internal structure of giant planets. Aims. SYMPA is the first instrument dedicated to the observations of free oscillations of Jupiter. Principles and theoretical performance have been presented in paper I. This second paper describes the data processing method, the real instrumental performance and presents the first results of a Jovian observation run, lead in 2005 at Teide Observatory. Methods. SYMPA is a Fourier transform spectrometer which works at fixed optical path difference. It produces Doppler shift maps of the observed object. Velocity amplitude of Jupiter's oscillations is expected below 60 cm/s. Results Despite light technical defects, the instrument demonstrated to work correctly, being limited only by photon noise, after a careful analysis. A noise level of about 12 cm/s has been reached on a 10-night observation run, with 21 % duty cycle, which is 5 time better than previous similar observations. However, no signal from Jupiter is clearly highlighted.

Motivation & Objective

  • To develop a dedicated instrument for detecting free oscillations in Jupiter, enabling direct probing of its internal structure.
  • To overcome limitations of previous Doppler spectrometry by using a Mach-Zehnder interferometer to produce phase-resolved velocity maps of Jupiter’s disk.
  • To improve sensitivity to low-amplitude oscillations (below 60 cm s⁻¹) through optimized data processing and calibration.
  • To assess the feasibility of ground-based seismology for giant planets and identify key technical and observational challenges.
  • To lay the groundwork for future space-based seismology missions targeting Jupiter’s interior structure.

Proposed method

  • SYMPA employs a Fourier transform spectrometer with fixed optical path difference, generating four phase-quadrature images of Jupiter’s disk using three Mg I absorption lines at 517 nm.
  • The instrument uses a Mach-Zehnder interferometer to measure the Doppler shift of reflected sunlight, converting phase differences into velocity maps across the planet’s disk.
  • Data reduction involves precise calibration for temperature drifts, intensity imbalances, and geometric distortions in the four output images.
  • Velocity maps are derived from interferometric phase retrieval, with noise levels estimated from photon statistics and instrumental stability.
  • Time-series analysis of the velocity maps is performed to search for periodic signals corresponding to p-mode oscillations, using power spectra and $(\ell,\nu)$ diagrams.
  • Signal-to-noise analysis accounts for duty cycle effects, estimating that only signals above ~25 cm s⁻¹ would be detectable at 1-σ level with the observed 21% duty cycle.

Experimental results

Research questions

  • RQ1Can a ground-based Fourier tachometer detect free oscillations in Jupiter with sufficient sensitivity to constrain its internal structure?
  • RQ2How does mode degeneracy from Jupiter’s rapid rotation affect the detectability of p-mode oscillations in velocity maps?
  • RQ3What is the limiting noise performance of SYMPA under real observing conditions, and how does it compare to previous instruments?
  • RQ4To what extent do atmospheric turbulence and low duty cycle degrade the detectability of weak oscillation signals?
  • RQ5Can the SYMPA instrument concept be adapted for future space-based seismology missions to Jupiter?

Key findings

  • SYMPA achieved a velocity noise level of approximately 12 cm s⁻¹ over a 10-night observation run at Teide Observatory, representing a fivefold improvement over previous similar observations.
  • Despite technical defects such as temperature dependence and intensity imbalance, the instrument’s performance was limited only by photon noise, confirming its potential for high-precision Doppler measurements.
  • No clear signal from Jupiter’s p-mode oscillations was detected, primarily due to mode degeneracy and the low 21% duty cycle, which reduces effective signal-to-noise by a factor of √0.2.
  • The absence of a detectable large separation (ν₀ ≈ 140 μHz) in the power spectra and $(\ell,\nu)$ diagrams suggests that signal dilution from degenerate modes significantly weakens the oscillation signature.
  • Theoretical estimates suggest that only oscillation amplitudes above ~25 cm s⁻¹ would be detectable at 1-σ confidence with the current observing conditions.
  • The instrument demonstrated the feasibility of using interferometric velocity mapping for giant planet seismology, paving the way for future space-based missions like ECHOES, which could achieve mm s⁻¹ noise levels with improved spatial resolution.

Read this paper